Economizer Side Panel

1.  Install economizer side panel to the right side of economizer, 

see Fig. 5 and 6.  Screw panel to economizer on left side, 

and into door bracket on right side of panel.

2.  Caulk all seams and gaps along sides and bottom of 

economizer and economizer side panel sheet metal.  Allow 

time for caulk to cure prior to placing unit into operation.

3. 

Reinstall unit’s filter access door.

TABLE 2

ECONOMIZER CONTROL MODULE LEDs

LED

When Lighted Indicates

Free Cool

Outdoor air is suitable for free cooling

Demand Control

Ventilation (DCV)

Indoor IAQ is above set point 

requirement more fresh air

Figure 8 - Mixed Air Sensor Location

Figure 7 - Wiring Detail

P142

TO

P10 J10

J142

ECONOMIZER

CONTROL

MODULE

RED

RED

GRY

YEL

J18

PN

K

GR

Y

WH

T

BLK

BLK

BLU

VIO

GRY

*PLUG

J24

PNK

DAMPER MOTOR

BLU

8

IAQ

SENSOR

(OPTION)

7

J9
P9

DIFFERENTIAL 

ENTHALPY

SENSOR

(OPTION)

SR

SR+

SO+

SO

T

T1

EF1 EF

AQ1

AQ

Actuator plug

*3 Pin High Voltage Power Exhaust Plug

POWER 

EXH

PLUG

5-PIN

OUTDOOR AIR

TEMPERATURE

SENSOR

PROVIDED

(ENTHALPY

OPTIONAL)

ECONOMIZER

Mixed Air

Sensor Provided (R1)

WIRE CONNECTIONS

Figure 7A - HVAC Control Box

Economizer

(J142, P142)

Economizer

Control Module

Mixed 

Air 

Sensor

Figure 9 - Label Installation

Apply wiring 

diagram here

Содержание Z1ECON16B-1

Страница 1: ...n outdoor air is suitable The mixed air temperature sensor measures the supply air sensible temperature An outdoor air sensor is used to determine whether outdoor air is suitable for free cooling The...

Страница 2: ...ure 3 Economizer Control shown w o relief damper Blower access panel backside Economizer control module in shipping location Must be relocated to control box Economizer damper actuator Plug for option...

Страница 3: ...GND to ground Yel Cool 1 to Y1 and Blue Cool 2 to Y2 Disconnect the factory installed terminals at TB1 Y1 and Y2 Connect these terminals to control male terminal Y1 and Y2 3 Attach the control harness...

Страница 4: ...ing Demand Control Ventilation DCV Indoor IAQ is above set point requirement more fresh air Figure 8 Mixed Air Sensor Location Figure 7 Wiring Detail P142 TO P10 J10 J142 ECONOMIZER CONTROL MODULE RED...

Страница 5: ...hen outdoor air enthalpy is lower than 73o F and 50 RH If indoor air is too warm or humid lower the setpoint to B At setting B free cooling will be enabled at 70o F and 50 RH Differential Enthalpy Sen...

Страница 6: ...roximate desired fresh air percentage Use care when adjusting minimum potentiometer to avoid damaging potentiometer Note Damper minimum position can be set lower than traditional minimum air requireme...

Страница 7: ...etting for proper demand control ventilation Economizer Operation When the outdoor air is suitable dampers will modulate between minimum position and full open to maintain 55o F 12o C supply air See T...

Страница 8: ...MPER MECHANICAL COOLING UNOCCUPIED OCCUPIED1 OF Closed Closed No F Closed Minimum No Y1 Closed Minimum STAGE 1 Y2 Closed Minimum STAGE 1 IAQ sensor can open damper to DCV max 1 Damper position when no...

Отзывы: