SL18XC1 SERIES
B. ROUTE HIGH VOLTAGE AND GROUND WIRES
Any excess high voltage field wiring should be trimmed and secured away from any low voltage field wiring. To facilitate a conduit, a
cutout is located in the bottom of the control box. Connect conduit to the control box using a proper conduit fitting.
CONTROL BOX
GROUND LUG*
CONTACTOR
WATERTIGHT
CONDUIT FITTING
WATERTIGHT
FLEXIBLE CONDUIT
TO SERVICE
DISCONNECT BOX
ACCESS VIEW
ELECTRICAL
INLET (HIGH
VOLTAGE)
WIRING ENTRY
POINTS
ELECTRICAL INLET (CONTROL WIRING —
LOW VOLTAGE). USE BUSHING
PROVIDED IN BAG ASSEMBLY HERE.
* Attach field-provided
green ground wire to
provided ground lug.
NOTE - Grounding wire
must be a single, contin
uous wire run from unit
ground lug to earth
ground.
DO NOT splice
wire.
FIGURE 7
STEP 2 -- ELECTRICAL (Continued) -- Outdoor Control (A175) Jumpers and Terminals
55
50
DEGREE
TARGET
45
DEGREE
TARGET
40
DEGREE
TARGET (DEFAULT)
55 50 45 40
55 50 45
40
55 50 45 40
55 50 45
40
DEGREE
TARGET
30
0
30
SECOND DELAY
SECOND DELAY
0
CUT FOR HUMIDITROL
®
- ENHANCED
DEHUMIFICATION ACCESSORY (EDA)
APPLICATIONS.
SECOND-STAGE LOCK-IN
TEMPERATURE
J4 - COMPRESSOR
SHIFT DELAY
DS TO R LINK - EDA
APPLICATION
J2 - SECOND-STAGE
LOCK-IN
TEMPERATURE
(DEFAULT)
7-SEGMENT DISPLAY
PUSH BUTTON
NOTE - LINK NOT APPLICABLE TO SINGLE-STAGE
UNIT. CUTTING LINK WILL HAVE NO AFFECT ON
OPERATION OF SINGLE-STAGE UNITS
.
MAX
90
DEGREE
TARGET
70
DEGREE
TARGET
70
DEGREE
TARGET
90
70
50
TARGET
90
70
50
90
70
50
MAX
90 70 50
J1 - DEFROST TERMINATION
TEMPERATURE
J3 - DEFROST AUTO
OFF
ON
JUMPER ON PINS 1 AND 2
DEFROST AUTO ENABLED
DEFROST AUTO DISABLED (DEFAULT)
90
70
50
(DEFAULT)
(DEFAULT WHEN JUMPER IS
REMOVED OR MISSING)
90
MAX
MAX
MAX
MAX
JUMPER ON PINS 2 AND 3
(HEAT PUMP ONLY)
(TWO-STAGE HEAT PUMP ONLY)
(TWO-STAGE UNIT ONLY)
(HEAT PUMP ONLY)
FIGURE 8