XC17 - 2 to 5 Ton Air Conditioner / Page 11
B
DISCONNECT
SWITCH
(By Others)
LENNOX
AIR
CONDITIONER
LENNOX
HEATING UNIT
OR
AIR HANDLER
UNIT
DISCONNECT
SWITCH
(By Others)
THERMOSTAT
(Optional)
C
D
A
INSTALLATION CLEARANCES - INCHES (MM)
FIELD WIRING
See
Notes
See
Notes
See
Notes
See
Notes
Service
A - Two Wire Power (not furnished)
B - Two Power (not furnished) See Electrical Data
C - Four Wire Low Voltage (not furnished) 18 ga. minimum
D - Six Wire Low Voltage (not furnished) 18 ga. minimum
All wiring must conform to NEC or CEC and local electrical codes.
OUTDOOR SOUND DATA
1
Unit
Model No.
Octave Band Sound Power Levels dBA, re 10
-12
Watts
1
Sound Rating
Number (dB)
Center Frequency - HZ
125
250
500
1000
2000
4000
8000
XC17-024
51.5
56.5
58.5
57.5
48.5
41.5
41.0
62
XC17-030
50.5
54.5
58.5
59.5
49.5
42.5
42.0
63
XC17-036
57.5
63.0
67.0
65.0
59.5
53.0
45.0
70
XC17-042
56.0
60.0
63.0
63.0
58.5
51.5
45.5
70
XC17-048
57.5
65.0
69.5
67.5
63.0
57.0
50.0
73
XC17-060
58.0
65.5
70.0
67.5
63.0
56.5
49.0
73
NOTE - the octave sound power data does not include tonal correction.
1
Tested according to AHRI Standard 270-2008 test conditions.
NOTES
One of the three sides must be 36 in. (914 mm).
One of the two remaining sides may be 12 in. (305 mm).
The remaining side may be 6 in. (152 mm).
Service Clearance − 30 in. (762 mm).
48 in. (1219 mm) clearance required on top of unit.
24 in. (610 mm) required between two units.
Содержание XC17-024
Страница 49: ...XC17 2 to 5 Ton Air Conditioner Page 49...
Страница 50: ...XC17 2 to 5 Ton Air Conditioner Page 50...
Страница 51: ......