background image

Elite

®

 Digital Touchscreen Thermostat 

/ Page 3

FEATURES

INSTALLER SYSTEM TESTS

Four tests are available for the Installer to check the HVAC
system after thermostat set−up has been completed.
1. Installer Test Cool
2. Installer Test Fan
3. Installer Test Heat
4. Installer Test Emergency Heat

Please refer to the Installation Instructions for detailed
information.

SPECIFICATIONS

For use with residential equipment only.

Temperature Setting Range

Heating − 40 to 90°F (4.5 to 32°C)
Cooling − 50 to 99°F (10 to 37°C)

Power Supply

24VAC (20 to 30VAC maximum), 50/60Hz
or 3 AAA batteries only (furnished)

Clock Accuracy

± 1 minute per month

Terminals

1 heat / 1 cool single stage
R, C, W, Y, G, O/B, L, S1, S2
3 heat / 2 cool multi−stage
R

C

, R, C, W, W

2

, Y, Y

2

, G, O/B, L, E, AUX, S1, S2

Dimensions (H x W x D)

5−1/2 x 7−7/8 x 1−5/16 in. (140 x 200 x 33 mm)

OPTIONAL ACCESSORIES − ORDER EXTRA

OUTDOOR TEMPERATURE SENSOR

When installed outdoors, sensor 

(X4148) 

allows

thermostat to display outdoor temperature.
NOTE − Sensor is required for dual fuel operation if
thermostat controls dual fuel system operation.

REVISIONS 

Sections

Description of Change

Front page

Removed Elite

®

 designation

.

Отзывы: