Lennox VRF V22B Series Скачать руководство пользователя страница 8

8

Troubleshooting

WARNING

!

ELECTRICAL SHOCK, FIRE, OR EXPLOSION HAZARD.
ever attempt to repair the indoor or outdoor unit yourself. System repairs must be performed by a licensed 

professional HVAC technician (or equivalent).

If any of the following conditions exist, immediately turn the system (indoor and outdoor units) off at the unit 

disconnect switch and call a licensed professional HVAC technician (or equivalent) for repairs:

•  The system does not receive a signal from the remote control or wired controller.
•  The remote control or wired controller indicate a system malfunction.
•  Water is leaking into the room from the indoor unit.
• 

The circuit breaker trips or the fuse blows frequently.

• 

Water or some other liquid has been spilled on or splashed into the indoor unit.

NORMAL OPERATION
If none of the above conditions exist, check the 

following items before calling for repairs. This can 

save you both time and money. The follow ing are 

signs of normal system operation.
System does not operate on command

The indoor fan does not start immediately after the ON/

OFF button on the remote control is pressed.
•  On an initial call for cooling, the operation/run light is lit 

to signal normal operation. There will be a delay after 

a cooling demand is introduced be fore unit operation 

begins. This delay protects the unit compressor and 

is normal.

•  When a heating demand is initiated, the opera tion 

light is lit to signal normal operation. The PRE-DEF 

indicator may be lit as well. The indoor unit fan will 

not operate until the indoor coil reaches a pre-set 

temperature. This prevents the delivery of cold air into 

the space and is nor mal.

Indoor fan is on; compressor is off

In certain normal operating modes, the indoor fan is on 

when the compressor is not operating.
• 

The system turns the compressor off and leaves the 

indoor fan on when the indoor coil falls to a preset 

temperature. This is normal operation and will prevent 

the indoor coil from freezing.

•  When the indoor fan is set for continuous opera tion, 

the fan continues to run when the temperat ure setting 

is reached and the compressor is de-energized.

White mist comes out of the indoor unit
•  During cooling operation,

 if the indoor relative 

humidity is very high and the indoor unit dis charge 

air louvers are very dirty, the indoor coil may freeze 

and a white mist (frozen vapor) may appear to come 

from the indoor unit. I

n this case, though the unit is 

not in need of repair, it does need to be cleaned 

by a licensed pro fessional HVAC technician (or 

equivalent).

•  During heating operation

 

when the operation 

mode switches from defrost to heating,

  mois ture 

generated by the defrost process becomes steam and 

may be seen as it is blown out of the indoor unit.

Sounds can be heard near the indoor unit

During certain parts of the heating or cooling pro cess, 

low swishing or groaning sounds may be heard near the 

unit as the system pressures equal ize. This is a normal 

occurrence.

Содержание VRF V22B Series

Страница 1: ...High Static Concealed Duct Units VCFB Ceiling or Floor Mounted Non Ducted Unit VVCB Air Handler USER S MANUAL VRF SYSTEMS Indoor Units 507922 02 05 2019 VRF Indoor Units THIS MANUAL MUST BE LEFT WITH...

Страница 2: ...f the unit and all other appliances that may cause a spark Call a licensed professional HVAC technician or equivalent to repair the leak DO NOT spray water on the indoor unit for any reason Do not tou...

Страница 3: ...DIFFUSER LOUVER ADJUSTMENT LEVER VCFB Ceiling or Floor Mounted Non Ducted Unit RETURN AIR DISCHARGE AIR LOUVER AIR FILTER VWMB Wall Mounted Non Ducted Unit RETURN AIR GROUNDING SCREW In control box DI...

Страница 4: ...HIB High Static Concealed Duct RIGHT SIDE VIEW LIQUID PIPE GAS PIPE AIR FLOW SUPPLY AIR DUCT OPENING AUXILIARY DRAIN CONNECTION Either Side PRIMARY DRAIN CONNECTION Either Side RETURN AIR DUCT OPENING...

Страница 5: ...charge air louvers downward during heating and outward during cooling VCFB Ceiling or Floor Mounted Units Use the wired controller or the remote control to set the position of the discharge air louver...

Страница 6: ...heck the filter more frequently if the unit is installed in an area with a large amount of dust The filter may be removed and cleaned or it should be replaced with a filter of like kind and size if it...

Страница 7: ...uld be held with the air entering side face down when using clean water to wash the filter Filter should be set aside to air dry after cleaning Do not place filter in direct sunlight or use any type o...

Страница 8: ...nitiated the opera tion light is lit to signal normal operation The PRE DEF indicator may be lit as well The indoor unit fan will not operate until the indoor coil reaches a pre set temperature This p...

Страница 9: ...the system Suction pressure is low due to possible refrigerant leak Clean indoor and or outdoor coil Clean or replace air filter Remove obstructions Close doors and windows Use curtains or blinds to...

Страница 10: ...odes will alternate so that all codes are shown Make note of the code E1 EE etc then reset the display by pressing the ON OFF button on the wireless remote controller Press the ON OFF button a second...

Страница 11: ...lowly EEPROM ERROR NOTES LED FLASHING SLOWLY 1 FLASH PER SECOND LED FLASHING FAST 2 FLASHES PER SECOND Shown on Indoor Unit Receiver LED Display Error Code Description FE No address E0 Mode conflict E...

Страница 12: ...12 Technical Support 1 844 GET VRF1 1 844 438 8731 vrftechsupport lennoxind com www LennoxVRF com Download the app from the Apple App Store or the Google Play store...

Отзывы: