TP − 3 to 5 Ton High−Efficiency, R−410A Heat Pump 

/ Page 4

FEATURES 

Cabinet

Heavy gauge steel cabinet with five station metal wash
process.
Powder paint finish provides superior rust and corrosion
protection.
Painted base section.
Control box is conveniently located with all controls
factory wired.
Corner patch plate allows access to compressor
components.
Drainage holes are provided in base section for moisture
removal.

Refrigerant Line Connections, Electrical Inlets,
Service Valves

Sweat connection vapor and liquid lines are located on
corner of unit cabinet.
Fully serviceable brass service valves prevent corrosion
and provide access to refrigerant system. Vapor valve can
be fully shut off, while liquid valve may be front seated to
manage refrigerant charge while servicing system.
Refrigerant line connections and field wiring inlets are
located in one central area of cabinet for easy access. See
dimension drawing.

OPTIONS

Hail Guards

Constructed of louvered heavy gauge steel painted to
match cabinet.
Surrounds unit on all four sides to prevent damage to the
coil.

Mounting Base

Provides permanent foundation for outdoor units.
High density polyethylene structural material is
lightweight, sturdy, sound absorbing and will withstand the
rigors of the sun, heat, cold, moisture, oil and refrigerant.
Will not mildew or rot.
Can be shipped singly or in packages of 6 to a carton.

Unit Stand-Off Kit

Black high density polyethylene feet are available to raise
unit off of mounting surface away from damaging
moisture.
Four feet are furnished per order number.

CONTROLS

Defrost Control

Solid-state control furnished as standard.
Gives a demand defrost cycle whenever system heating
performance falls below optimum levels. The sensing
element on coil determines when defrost cycle is required
and when to terminate cycle.
Anti−short cycle (5 minutes) incorporated into the board.
Diagnostic LED’s furnished as an aid in troubleshooting.
Conveniently located in control box.

OPTIONS

Freezestat

Installs on or near the discharge line of the indoor coil or on
the suction line.
Senses suction line temperature and cycles the
compressor off when suction line temperature falls below
it’s setpoint.
Opens at 29°F and closes at 58°F.

L Connection

®

 Network

See L Connection Engineering Handbook Bulletin in
Controls section for details.

Low Ambient Control

Air conditioners operate satisfactorily down to 45°F
outdoor air temperature without any additional controls.
Two low ambient control options are available for field
installation.
The Low Ambient Control Kit allows unit operation down
to 30°F.
The second control option allows unit operation down to
0°F. This option requires that the outdoor fan motor and
capacitor be changed. See Low Ambient Control Option
table, page 7, for ordering information.
Freezestat should be installed on compressors equipped
with a low ambient kit.
A compressor lock−out thermostat should be added to
terminate compressor operation below recommended
operation conditions (on/off operation, 30°F or modulating
operation, 0°F).

Mild Weather Kit

Heat pump units operate satisfactorily in the heating
mode at outdoor air temperatures up to 75

_

F.

Mild Weather Kit can be field installed, allowing heating
operation above 75

_

F.

Monitor Kit − Service Light

Contains ambient compensating thermistor and service
light thermostat.
For use with thermostats requiring input for indicator lights.

Outdoor Thermostat Kit

An outdoor thermostat can be used to lock out some of the
electric heating elements on indoor units where two stage
control is applicable.
Outdoor thermostat maintains the heating load on the low
power input as long as possible before allowing the full
power load to come on the line.
Thermostat kit and mounting box must be ordered extra.

Thermostat

Thermostat not furnished with unit. See Thermostat
bulletins in Controls Section and Lennox Price Book.

Time Delay Relay Kit

Delays the indoor blower−off time during the cooling cycle.
See ARI Rating Tables for usage.

H

I

J

Содержание TPA036H4

Страница 1: ...T P A Y 1 036 h 4 4 n Major Design Sequence A 1st Generation B 2nd Generation Brand Family T T Classt Product Line Unit Type P Heat Pump Outdoor Unit Nominal Cooling Capacity Tons 036 3 Tons 042 3 5...

Страница 2: ...ing COP up to 4 04 HSPF Region IV 9 0 3 through 5 tons Three phase power supply Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof Designed for applicatio...

Страница 3: ...due low refrigerant charge conditions SPST normally closed switch automatic reset switch mounted on suction line Compressor Scroll Compressor Compressor features high efficiency with uniform suction...

Страница 4: ...shed as an aid in troubleshooting Conveniently located in control box OPTIONS Freezestat Installs on or near the discharge line of the indoor coil or on the suction line Senses suction line temperatur...

Страница 5: ...E1 Accessories For Touchscreen Thermostat Locking cover clear C0MISC15AE1 1 Remote sensors for C0STAT02AE1L can be applied in the following combinations 1 C0SNZN01AE1 2 C0SNZN73AE1 2 C0SNZN01AE1 and 1...

Страница 6: ...13 5 6 0 13 7 6 2 16 0 7 8 p Locked Rotor Amps 71 38 88 44 83 1 41 110 52 Power Factor 85 84 83 81 90 92 90 91 Outdoor Fan Motor Full Load Amps 1 8 1 0 1 8 1 0 1 8 1 0 1 8 1 0 Fan Motor Locked Rotor...

Страница 7: ...6H4 78 5 77 5 77 5 74 5 69 5 63 5 61 5 79 TPA042H4 76 5 78 78 5 73 5 69 5 63 5 58 5 79 TPA048H4 75 5 78 78 5 75 70 63 5 58 5 80 TPA060H4 75 77 5 77 5 75 5 70 65 65 80 NOTE the octave sound power data...

Страница 8: ...0 A ELECTRICAL INLETS LIQUID LINE CONNECTION TOP VIEW BASE SECTION 4 3 8 111 COMPRESSOR COIL DRAIN OUTLETS Around perimeter of base OPTIONAL UNIT STAND OFF KIT 4 Field Installed B C A OPTIONAL UNIT ST...

Страница 9: ...andlers 34 400 35 400 21 400 14 00 12 00 8 20 7 20 2865 2790 2570 3 72 2 44 4 CBX32M 042 Multi Position 2 49L25 34 400 35 600 21 400 14 00 12 00 8 20 7 20 2865 2785 2575 3 74 2 44 4 CBX32M 036 Multi P...

Страница 10: ...00 12 50 8 00 6 70 2830 2910 2655 3 46 2 30 CX34 44 48C 6F 4 G71MPP 60C 090 Factory TXV 35 400 34 600 20 800 14 50 12 50 8 00 6 70 2830 2935 2695 3 46 2 26 CX34 43B 6F 4 G61MPV 36B 045 Factory TXV 35...

Страница 11: ...2 00 8 20 6 70 2935 2930 2705 3 48 2 28 CH33 44 48B 2F 4 G61MPV 36B 045 2 49L25 35 200 34 800 21 000 14 00 12 00 8 20 6 70 2935 2920 2700 3 50 2 28 CH33 44 48B 2F 4 G61MPV 36B 070 2 49L25 35 200 34 80...

Страница 12: ...3195 2920 3 80 2 62 CX34 60D 6F 4 G71MPP 60D 135 2 49L25 42 500 41 500 26 200 15 00 13 00 9 00 7 70 3400 3190 2915 3 82 2 64 CX34 62D 6F 4 G61MPV 60D 135 2 49L25 42 500 41 500 26 200 15 00 13 00 9 00...

Страница 13: ...200 13 00 11 00 7 70 6 70 3820 3275 3025 3 80 2 64 3 CH23 68 2 49L25 42 000 42 500 27 000 13 00 11 00 7 70 6 70 3820 3395 3095 3 66 2 56 3 CH33 43B 2F 2 49L25 Horizontal Indoor Coils Furnaces Horizont...

Страница 14: ...2 76 CH23 68 4 G61MPV 60C 090 2 49L25 42 500 42 000 26 600 14 50 12 00 8 50 8 00 3540 3085 2830 4 00 2 76 CH23 68 4 G71MPP 60C 090 2 49L25 42 500 42 000 26 600 14 50 12 00 8 50 8 00 3540 3065 2815 4...

Страница 15: ...ry TXV 50 000 47 000 30 200 14 50 12 00 8 20 7 20 4165 3725 3435 3 70 2 58 CX34 62C 6F 4 G71MPP 60C 110 Factory TXV 50 000 47 000 30 200 14 50 12 00 8 20 7 20 4165 3730 3440 3 70 2 58 CX34 62C 6F 4 G6...

Страница 16: ...000 14 50 12 00 8 20 7 20 4125 3585 3320 3 84 2 64 CH23 68 4 G60UHV 60C 110 2 91M02 49 500 47 000 30 000 14 50 12 00 8 20 7 20 4125 3575 3310 3 86 2 66 CH23 68 4 G61MPV 60D 135 2 91M02 49 500 47 000 3...

Страница 17: ...CH33 50 60C 2F 4 G60UHV 60C 110 2 91M02 57 000 54 500 35 800 13 50 11 00 8 20 7 20 5180 4950 4385 3 22 2 40 CH33 50 60C 2F 4 G61MPV 60C 110 2 91M02 57 000 54 500 35 800 13 50 11 00 8 20 7 20 5180 4950...

Страница 18: ...ation Retain Reference Article when specifying products and installation by an industry reference standard If retained list standard s referenced in this section Indicate issuing authority name acrony...

Страница 19: ...ipped loose showing final location in assembly d Field wiring diagrams e Dimensions internal and external construction details installation clearances recommended method of installation sizes and loca...

Страница 20: ...waste into landfill site demonstrates an inefficient use of natural resources and consumes valuable landfill space 1 Separate waste materials for Reuse And Recycling _____ in accordance with Section...

Страница 21: ...urrent and temperature protection d Crankcase heater e Accessories 1 Low Ambient Cut Off nonadjustable switch to prevent compressor operation at outdoor temperatures below 35 degrees F 2 degrees C 2 C...

Страница 22: ...ating thermistor and service light thermostat 5 Outdoor Thermostat Kit to lock out some electric heating elements on indoor units where 2 stage control is applicable 6 Thermostat 7 Time Delay Relay Ki...

Страница 23: ......

Страница 24: ...ittment to quality Specifications Ratings and Dimensions subject to change without notice and without incurring liability Improper installation adjustment alteration service or maintenance can cause p...

Отзывы: