E2 — Microinventer Data Sheet 

ENPHASE MICROINVERTER

How the Enphase Microinverter Works

The Enphase Microinverter maximizes energy

production from the solar module array. Each Enphase

Microinverter is individually installed on one solar

module in the array.
This unique con’iguration means that an individual

Maximum Peak Power Point Tracker (MPPT) controls

each solar module. This ensures that the maximum

power available from each solar module is exported to

the utility grid regardless of the performance of the other

solar modules in the array.
Even if individual solar modules in the array are

affected by shading, soiling or orientation, the Enphase

Microinverter ensures optimum performance for each

associated solar module. The result is maximum energy

production from the SunSource

 Energy System.

Enphase Microinverters for 3

Phase Applications

Each Enphase Microinverter automatically connects to

one phase of a 3

phase system. It senses the grid and

synchronizes to that phase. When applied in groups of

three it creates a balanced 3

phase system. If systems

are installed in something other than multiples of three a

small imbalance will be created across the phases. The

maximum output of each inverter is 0.92A. This would

be the maximum imbalance possible.

Enphase Microinverter Status LED Indications and

Error Reporting

Startup LED Operation:
Six short green blinks when DC power is ’irst applied

to the Enphase Microinverter indicates a successful

microinverter startup sequence.
Six short red blinks when DC power is ’irst applied to

the Enphase Microinverter indicates a failure during

microinverter startup.

Post

Startup LED Operations:

Flashing Green

 

 Producing power and

communicating with Envoy

Flashing Orange

   Producing power and not

communicating with Envoy

Flashing Red

   Not producing power

GFDI Fault:

A solid red status LED when DC power has been

cycled, indicates the Enphase Microinverter has

detected a ground fault (GFDI) error. The LED will

remain red and the fault will continue to be reported by

the Envoy until the error has been cleared. The error

can only be cleared via the Envoy after the ground fault

condition has been remedied.

Other Faults:

All other faults are reported to the Envoy.

Содержание SunSource

Страница 1: ...ractive solar photovoltaic system generally requires a permit from the local authority having jurisdiction AHJ This document provides a typical format for a residential permit application to install a...

Страница 2: ...C power is connected directly to an Enphase microinventer mounted below each module 240VAC power from the microinventer passes through a renewable energy credit meter next through a disconnect switch...

Страница 3: ...1 0 SOUTH FACING ROOF 3 18 KW PV ARRAY DETAILS S 12 SW 265 solar PV AC modules in one AC circuit S 12 Enphase M215 60 2LL S22 240 S 90MPH designed wind speed and exposure category B S Composition shi...

Страница 4: ...Page 4 B1 Wiring Diagram Figure 1 SunSource Home Energy System Electrical Layout...

Страница 5: ...Page 5 B1 Alternate Wiring Diagram...

Страница 6: ...Conduit de rate factor 1 S Maximum wire temperature allowed 167 F 75 C S Selected wire size 10 AWG S Insulation type THHN THWNN 2 Specified wire ampacity 30 45 amps 3 Conduit size S Conduit specified...

Страница 7: ...Page 7 C1 PVWatts Calculations...

Страница 8: ...Page 8 C1 PVWatts Calculations continued...

Страница 9: ...HVAC DISCONNECT SWITCH USED ON UNIT CB10 PLASTIC COVER USED ON UNIT CB40 PLASTIC COVER USED NEXT TO CIRCUIT BREAKER IN MAIN PANEL SOURCE CIRCUIT DISCONNECT FOR SOLAR DISCONNECT BOTH POWER SOURCES BEFO...

Страница 10: ...Loads Two rail system 113 psf downward 50 psf upward THERMAL CHARACTERISTICS 265 Wp NOCT 115 F TCISC 0 004 K TCVOC 0 30 K TCPMPP 0 45 K Operating Temp 40 F to 185 F ADDITIONAL DATA 265 Wp Power Toler...

Страница 11: ...Page 11 E1 Module Data Sheet continued DIMENSIONS INCHES MM 11 3 8 41 3 8 66 1 1 4 39 3 8 1000 37 1 2 4 1 4 952 2 1 2 1676 1051 289 1 3 8 35 108 1 1 4 32 5 8 16...

Страница 12: ...oups of three it creates a balanced 3 phase system If systems are installed in something other than multiples of three a small imbalance will be created across the phases The maximum output of each in...

Страница 13: ...V 183 229V 240V 211 264V Extended Voltage Range 208V 179 232V 240V 206 269V Nominal Frequency Range 60 0 59 3 60 5 Hz 60 0 59 3 60 5 Hz Extended Frequency Range 60 0 59 2 60 6 Hz 60 0 59 2 60 6 Hz Pow...

Страница 14: ...nels are rated for coastal conditions in Florida Install the flashing below the upper shingle to allow water to run around the raised penetration point Seal the penetration and lag screws with appropr...

Страница 15: ...Page 15 QUICK MOUNT PV CONTINUED...

Отзывы: