Wireless Remote Functions (Continued)

Press the TEMP button again to
display the outdoor ambient tem­
perature       icon. The outdoor
ambient temperature display is
not available on this system.

On occasion, the remote control
will display the temperature that
was not selected (indoor ambient
temperature or setting tempera­
ture). The selected temperature
will return to the display screen
after 5 seconds.

NOTE - The TEMP button can
also be used to temporarily dis­
play the indoor ambient tempera­
ture on the indoor unit display
panel.

LOUVER SETTING button

Use the LOUVER SETTING but­
ton to choose a preferred louver
setting, rather than the default
setting, during fan operation.
Refer to the following section for
louver operation.

TEMP button

Use the TEMP button to change
the temperature display shown
on the remote control. When ini­
tially powered on, the current
temperature setting is displayed,
along with the      icon.

Press the TEMP button once 
to alter the display to show the
current indoor ambient tempera­
ture, along with the      icon. The
indoor temperature sensor is in
the indoor unit.

Louver Operation

LOUVER SETTING button

Use the LOUVER SETTING
button to choose a preferred
setting for the indoor unit
directional louver.

NOTE - Actual louver
position is different than
what is shown on remote
icon. See comparison to
the right.

Press the LOUVER
SETTING button      once to
activate the full-range
oscillation mode from top to
bottom, then back again. The
louver icon     will appear in
the lower section of the
screen.

Press the LOUVER
SETTING button again to
turn the feature OFF. The
louver will return to the
default setting.

Press the LOUVER
SETTING button twice and
continue to press the button
to scroll through the five
available fixed positions

AND three other oscillating
positions.

o r a b o v e

REMOTE

CONTROL ICON

POSITION

ACTUAL
LOUVER

POSITION

To return the louver to the
default position, press the
LOUVER SETTING button
until the icon       disappears.

Default Louver Positions

When the louver setting icon
is not displayed, the louver is
in the DEFAULT position.

When the remote control is
powered OFF, the default
position is fully closed.

When the remote control is
set so that the unit is in
COOLING, AUTO COOLING,
or DEHUMIDIFICATION
mode, the louver is in a fixed
upward position     .

When the remote control is
set so that the unit is in HEAT
or AUTO HEATING mode and
the outdoor unit is OFF, the
louver is fixed in the second
position      pointed upward. If
the outdoor unit is ON, the
louver is fixed in a downward
position      .

When the remote is set for
continuous indoor fan to be
ON, the louver is fixed in an
upward position      .

LOUVER

SETTING

ICON

Содержание MS8 SERIES

Страница 1: ...is manual is the property of the homeowner and must be left with the user 2012 Lennox Industries Inc Dallas Texas USA MS8 Single Zone Mini Split System Air Conditioners and Heat Pumps 507022 01 10 201...

Страница 2: ...essional service technician or equivalent must annually inspect this system This unit must be properly grounded Do not use this system if any part has been underwater A flood dam aged appliance is ext...

Страница 3: ...Tape e p i p n o i t c e n n o C Air inlet Typical indoor unit shown Actual unit may be slightly different Front Panel Display Air outlet Filter Directional Louver Wireless remote control Temperature...

Страница 4: ...ixed in a downward position In climates with very low winter temperatures it may be necessary to supplement heating by addi tional means space heater fireplace etc In heating mode the operating range...

Страница 5: ...r unlock the remote control buttons When the remote control is locked the icon is displayed AUTO COOL DEHUMIDIFICATION FAN HEAT FAN button Press this button to select fan speed AUTO fan is the default...

Страница 6: ...button and use and buttons to set time for sys tem shutdown When desired time is displayed press TIMER OFF button again Press SLEEP button to cancel sleep function In cooling mode SLEEP function incre...

Страница 7: ...ver NOTE Actual louver position is different than what is shown on remote icon See comparison to the right Press the LOUVER SETTING button once to activate the full range oscillation mode from top to...

Страница 8: ...uver Press once to activate full range oscillation Press more than once to scroll through and select one of five fixed positions or one of three other oscillating positions If function is activated wh...

Страница 9: ...thin its receiving range to ensure proper system control Control should be kept at least 3 feet 914mm away from other electrical appliances televisions stereos etc to prevent signal interference If re...

Страница 10: ...ts on top of unit or around unit that may be obstructing air flow Check to make sure that indoor unit and wall bracket are secure and have not been damaged Use a clean dry cloth to gently remove dust...

Страница 11: ...nected or has circuit breaker tripped Is power shut down System is not cooling or heating efficiently Is temperature setting correct Are either the air inlet or air outlet blocked on the outdoor or in...

Страница 12: ...stem an error code will replace the temperature setting displayed on the front cover of the indoor unit If more than one error has occurred the codes will alternate so that all codes are shown Make no...