For the unit with cooling capacity of 2300W
at least 3cm above the floor
Note:
installing the outdoor unit.
Make sure the support can withstand at least
four times of the unit weight.
The outdoor unit should be installed at least
joint. (for the model with heating tube, the
installation height should be no less than 20cm.)
~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10000W
~16000W, 10 expansion screws are needed.
Installation of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
1. Place the outdoor unit on the
support.
Fix the foot holes of outdoor unit
with bolts.
2.
2. Connect the drain hose into the drain vent.
foot holes
foot holes
chassis
outdoor drain joint
30
drain vent
Drain hose
Connect the outdoor drain joint into
the hole on the chassis, as shown in
the picture below.
Step two: install drain joint
(Only for some models)
1.
NOTE:
As for the shape of drainage joint,
please refer to the current product.
Do not install the drainage joint in the
severe cold area. Otherwise,it will be
frosted and then cause malfunction.