28
4.Put wiring cover back and then tighten the screw.
5.Close the panel.
Installation of indoor unit
Note:
●
All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
● For the air conditioner without plug, an
air switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
3. Remove the wire clip; connect the power
connection wire to the wiring terminal
according to the color; tighten the screw
with wire clip.
Note: the wiring board is for reference only,please refer to th
e actual one.
power connection
wire
cable-cross
hole
2. Make the power connection wire go
through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
N(1) 2
3
blue black brown yellow-
green
Outdoor unit connection
24K Cool only type:
outdoor unit connection
N(1) 2
blue black yellow-
green
09
、
12
、
18K Cool only type:
09
、
12K
、
18K Heat pump type:
N(1) 2
3
4
5
blue
violet orange
black brown
yellow-
green
Outdoor unit connection
24K Heat pump type:
N(1) 2
4
5
blue
violet orange
black
yellow-
green
Outdoor unit connection