background image

Page 3

ON

OFF

FIGURE 4

HONEYWELL VR8204 SERIES GAS VALVE

GAS VALVE SHOWN IN OFF POSITION

GAS VALVE

SELECTOR

ARM

IN OFF

POSITION

ROBERTSHAW 7200 GAS VALVE

FIGURE 5

 7- Wait fifteen (15) minutes to clear out any gas. If you

then smell gas, 

STOP

! Immediately call your gas supĆ

plier from a neighbor's phone. Follow the gas suppliĆ

er's  instructions.  If  you  do  not  smell  gas  go  to  next

step.

 8- On Robertshaw 7100D and Honeywell VR8204 gas

valves,  turn  knob  on  gas  valve  counterclockĆ
wise

 

 

to 

ON

.  Units with Robertshaw 7200 gas

valve, depress lever and move to 

ON

 position. Do

not force.

 9- Replace control access panel.
10- Turn on all electrical power to unit.
11- Set thermostat to desired setting.

NOTE-When  unit  is  first  started,  steps  1  through  11
may need to be repeated to purge air from pilot line.

12- If the appliance still will not operate, follow the inĆ

structions To Turn Off Gas To Unit" and call your

service technician or gas supplier.

To Turn Off Gas To Unit

 1- Set thermostat to lowest setting.
 2- Turn off all electrical power to unit if service is to be

performed.

 3- Remove control access panel.

 4- On Robertshaw 7100D and Honeywell VR8204 gas

valves, turn knob on gas valve clockwise

 to  

OFF

.

Units with Robertshaw 7200 gas valve, depress lever
and move to 

OFF

 position. Do not force.

 5- Replace control access panel.

FILTERS

G17 and G17X series units are equipped with permaĆ

nent internal filters which should be inspected monthly

and cleaned when necessary to assure proper furnace

operation. See table 1 for filter sizes. Use the following

procedure to clean filter. Refer to figure 6.

TABLE 1

MODEL NO.

FILTER SIZE

Q2-50, Q3-75, Q4X-75

Q3/4-100

Q5/6-100, Q5/6-125

16 X 25 X 1

20 X 25 X 1

SIDE RETURN BOTTOM RETURN

16 X 25 X 1

25 X 26 X 1

 1- Turn off electric power to furnace.
 2- Remove blower access panel.
 3- Disconnect retention springs using finger loops and

remove filter.

 4- Clean filter with cold water. Direct water through filĆ

ter in the opposite direction of air flow.

 5- Allow filter to dry.
 6- Replace  filter,  reconnect  springs,  replace  blower

access panel and restore power to unit.

FILTER RETENTION SPRING LOCATION FOR

BOTTOM RETURN AIR OPENING

FILTER RETENTION SPRING LOCATION

 FOR SIDE RETURN AIR OPENING

FIGURE 6

FINGER

LOOPS

FINGER

LOOP

FINGER

LOOP

CRIMP THIS END

OF SPRING

CRIMP THIS END

OF SPRING

Содержание HCF RTL G 17

Страница 1: ... other flammable vapors and liqĆ uids in the vicinity of this or any other appliance Installation and service must be performed by a qualified installer service agency or the gas suppliĆ er D Do not try to light any appliance D Open windows D Do not touch any electrical switch do not use any phone in your building D Immediately call your gas supplier from a neighbor s phone Follow the gas suppliĆ ...

Страница 2: ...cause cancer Fiberglass wool may also cause respiratory skin and eye irritation To reduce exposure to this substance or for furĆ ther information consult material safety data sheets available from address shown below or contact your supervisor Lennox Industries Inc P O Box 799900 Dallas TX 75379 9900 WARNING If overheating occurs or if gas supply fails to shut off shut off the manual gas valve to ...

Страница 3: ...osion may result causing property damage personal injury or loss of life BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified servi...

Страница 4: ...o be performed 3 Remove control access panel 4 On Robertshaw 7100D and Honeywell VR8204 gas valves turn knob on gas valve clockwise to OFF Units with Robertshaw 7200 gas valve depress lever and move to OFF position Do not force 5 Replace control access panel FILTERS G17 and G17X series units are equipped with permaĆ nent internal filters which should be inspected monthly and cleaned when necessary...

Страница 5: ...rs and pilot for corrosion deterioration or deposits of debris Remove any obstructions Contact your Lennox dealer for a periodic unit inspection by a qualified service technician BLOCKED VENT SHUT OFF SYSTEM Your Lennox furnace is equipped with a blocked vent shut off switch and a flame roll out safety switch The blocked vent shut off switch shuts off the gas supply to the furnace in the event of ...

Отзывы: