• 18 •
Application Guide / FLEXAIR-AGU-1505-E
As managing fresh air is becoming mandatory in most buildings
economiser is now
fi
tted as standard with the
FLEXAIR
.
Advanced control pack
Where a higher level of controllability is required to make the
FLEXAIR
even more
fl
exible, LENNOX have compiled a pack
that includes two advanced control features.
•
"Enthalpy control on economiser"
.
The eCLIMATIC and its humidity sensors (return air and fresh
air) ensures that the economiser does not use 100% fresh
air if the outside air has a higher enthalpy than the return air.
This feature is relevant in regions where the relative humidity
is high or when the desired room air condition is very dry.
•
"Humidity control"
The eCLIMATIC and its humidity sensors, analyze dry and
wet bulb temperatures to control dehumidi
fi
cation. Humidity
control is only available if ambient temperature is in cooling
or dead zone. The dehumidi
fi
cation algorithm can dry the air
by passing it through the coil in cooling mode.
A
speci
fi
c function in the program can be activated to control
the minimum supply air temperature, by maintaining it equal
to the heating set point, using auxiliary heaters (Electric, Hot
water coil or gas burner).
A proportional 0-10V contact is also available to control an
external humidi
fi
er.
Indoor air quality sensor
Indoor air quality is controlled from the eCLIMATIC main
controller. A VOC (Volatile Organic Component) sensor detects
the amount of CO2 in the ambient air between 0 and 2000PPM.
(This obviously varies depending upon space occupancy levels).
The VOC sensor sends a proportional signal (0-20mA) to the
eCLIMATIC controller which will then modulate the fresh air.
Low Noise Option
As rooftops are often installed in a noise sensitive area, LENNOX
proposes a low noise option on
FLEXAIR
. To achieve low noise
level,
FLEXAIR
receives a quieter fan, a compressor jacket and
is fully equipped with acoustic isolation in the refrigerating box.
Anti corrosion protection
When the units are installed in potentially aggressive
environments, which can often be the case for example in coastal
environments, it is often a requirement that the coils are specially
treated to protect them against the corrosive effects.
LenGuard™ anti-corrosion treatment is available for condensers,
evaporators and hot water coil.
2.6- REFRIGERATION OPTIONS
2.7- FRESH AIR OPTIONS
2- OPTIONS DESCRIPTION
Содержание FLEXAIR FAC 085
Страница 2: ......
Страница 4: ...2 Application Guide FLEXAIR AGU 1505 E...
Страница 58: ...56 FAC FAH FAG FAM 85 100 120 Application Guide FLEXAIR AGU 1505 E 11 DIMENSIONS G A A A G M A G 11 1 M...
Страница 59: ...57 FAC FAH FAG FAM 085 100 120 Application Guide FLEXAIR AGU 1505 E 11 DIMENSIONS G A A A G M A G...
Страница 60: ...58 FAC FAH FAG FAM 85 100 120 Application Guide FLEXAIR AGU 1505 E GENERAL ARRANGEMENTS DRAWINGS 11 DIMENSIONS...
Страница 61: ...59 FAC FAH FAG FAM 085 100 120 Application Guide FLEXAIR AGU 1505 E GENERAL ARRANGEMENTS DRAWINGS 11 DIMENSIONS...
Страница 62: ...60 FAC FAH FAG FAM 150 170 Application Guide FLEXAIR AGU 1505 E GENERAL ARRANGEMENTS DRAWINGS 11 DIMENSIONS...
Страница 63: ...61 FAC FAH FAG FAM 150 170 Application Guide FLEXAIR AGU 1505 E GENERAL ARRANGEMENTS DRAWINGS 11 DIMENSIONS...
Страница 64: ...62 FAC FAH FAG FAM 150 170 Application Guide FLEXAIR AGU 1505 E GENERAL ARRANGEMENTS DRAWINGS 11 DIMENSIONS...
Страница 65: ...63 FAC FAH FAG FAM 150 170 Application Guide FLEXAIR AGU 1505 E GENERAL ARRANGEMENTS DRAWINGS 11 DIMENSIONS...
Страница 66: ...64 FAC FAH FAG FAM 200 230 Application Guide FLEXAIR AGU 1505 E GENERAL ARRANGEMENTS DRAWINGS 11 DIMENSIONS...
Страница 67: ...65 FAC FAH FAG FAM 200 230 Application Guide FLEXAIR AGU 1505 E GENERAL ARRANGEMENTS DRAWINGS 11 DIMENSIONS...
Страница 68: ...66 FAC FAH FAG FAM 200 230 Application Guide FLEXAIR AGU 1505 E GENERAL ARRANGEMENTS DRAWINGS 11 DIMENSIONS...
Страница 69: ...67 FAC FAH FAG FAM 200 230 Application Guide FLEXAIR AGU 1505 E GENERAL ARRANGEMENTS DRAWINGS 11 DIMENSIONS...
Страница 79: ......