Page 2
SPECIFICATIONS
Model No.
F8AUH**−24−045
F8AUH**−24−045X
F8AUH**−24−060
F8AUH**−36−060
F8AUH**−36−060X
F8AUH**−24−075
F8AUH**−36−075
F8AUH**−36−075X
Input Btuh (kW)
45,000 (13.2)
60,000 (17.6)
60,000 (17.6)
75,000 (22.0)
75,000 (22.0)
Output Btuh (kW)
39,600 (10.8)
49,200 (14.4)
49,200 (14.4)
61,700 (18.1)
61,700 (18.1)
AFUE
80.1%
80.5%
80.5%
80.1%
80.0%
California Seasonal Efficiency
75.4%
76.4%
75.9%
76.8%
76.8%
Flue size connection dia. − in. (mm) round
3 (76)
3 (76)
3 (76)
4 (102)
4 (102)
Temperature rise range −
_
F (
_
C)
30 − 60 (17 − 33) 45 − 75 (25 − 42) 45 − 75 (25 − 42) 45 − 75 (25 − 42) 45 − 75 (25 − 42)
High static AGA/CGA cert. − in wg. (Pa)
.50 (125)
.50 (125)
.50 (125)
.50 (125)
.50 (125)
Gas Piping Size IPS Nat. or LPG/propane
1/2 (13)
1/2 (13)
1/2 (13)
1/2 (13)
1/2 (13)
Blower wheel nominal
in.
9 x 7
9 x 7
10 x 7
9 x 7
10 x 7
Blower wheel nominal
diameter x width
mm
229 x 178
229 x 178
254 x 178
229 x 178
254 x 178
Blower motor output − hp (W)
1/4 (187)
1/4 (187)
1/3 (224)
1/4 (187)
1/3 (224)
Nominal cooling
Tons
1, 1.5 or 2
1, 1.5 or 2
2, 2.5 or 3
1, 1.5 or 2
2, 2.5 or 3
Nominal cooling
that can be added
kW
3.5, 5.3 or 7.0
3.5, 5.3 or 7.0
7.0, 8.8 or 10.6
3.5, 5.3 or 7.0
7.0, 8.8 or 10.6
Shipping weight − lbs. (kg) 1 package
130 (59)
130 (59)
135 (61)
135 (61)
135 (61)
Electrical characteristics
120 volts − 60 hertz − 1 phase (less than 12 amps) All models
OPTIONAL ACCESSORIES − Must Be Ordered Extra
Hanging Bracket Kit
46J66
46J66
46J66
46J66
46J66
High Altitude Pressure Switch Kits
No Change
No Change
No Change
88J80
88J80
LPG/propane kit
38K84
38K84
38K84
38K84
38K84
Sidewall Power Venting Kit
79J15
79J15
79J15
79J15
79J15
Twinning Kit
15L38
15L38
15L38
15L38
15L38
Up−Flow/Horizontal Filter and Filter Rack Kits
No. & sizeoffilters− in. (mm)
32J02 (single)
66K64 (ten)
(1) 16 x 20 x 1
(406 x 508 x 25)
32J02 (single)
66K64 (ten)
(1) 16 x 20 x 1
(406 x 508 x 25)
32J02 (single)
66K64 (ten)
(1) 16 x 20 x 1
(406 x 508 x 25)
32J02 (single)
66K64 (ten)
(1) 16 x 20 x 1
(406 x 508 x 25)
32J02 (single)
66K64 (ten)
(1) 16 x 20 x 1
(406 x 508 x 25)
*Variable Field.
Annual Fuel Utilization Efficiency based on US DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating
for non−weatherized furnaces.
For proper operation at altitudes over 4500 ft. (1370 m).
Required for horizontal venting applications.