Energence
®
Packaged Electric / Electric 26 to 44 kW 50 Hz / Page 23
HUMIDITROL
®
DEHUMIDIFICATION SYSTEM RATINGS
35 KW - LCH120H4B with HUMIDITROL
®
DEHUMIDIFICATION
OPERATING (1ST STAGE)
Entering
Wet
Bulb
Temper-
ature
Total
Air
Volume
Outdoor Air Temperature Entering Outdoor Coil
18.3°C
23.8°C
29.4°C
35°C
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Dry Bulb
Dry Bulb
Dry Bulb
Dry Bulb
L/s
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
17.2°C
1510
13.2
2.3
0.50 0.73 0.97
11.3
2.6
0.40 0.68 0.97
9.4
2.9
0.23 0.63 0.98
7.4
3.1
0.01
0.49
1.00
1890
15.7
2.3
0.58 0.88 1.00
13.0
2.6
0.47 0.87 1.00
10.4
2.9
0.32 0.85 0.93
7.8
3.1
-0.01 0.80
0.97
2265
18.3
2.3
0.65 0.97 1.00
14.9
2.6
0.58 0.98 1.00
11.6
2.9
0.43 1.00 1.00
8.2
3.1
-0.02 0.97
0.80
19.4°C
1510
16.3
2.4
0.31 0.51 0.69
14.0
2.6
0.20 0.43 0.67
11.6
2.9
0.01 0.31 0.62
9.2
3.2
-0.06 0.08
0.53
1890
18.1
2.4
0.35 0.58 0.82
15.3
2.6
0.24 0.52 0.81
12.5
2.9
0.05 0.40 0.81
9.7
3.2
-0.12 0.16
0.78
2265
20.0
2.4
0.39 0.66 0.94
16.7
2.7
0.26 0.59 0.95
13.4
2.9
0.06 0.53 0.94
10.1
3.2
-0.18 0.30
0.98
21.7°C
1510
19.5
2.4
0.17 0.33 0.50
16.7
2.7
0.06 0.24 0.43
13.8
2.9
-0.12 0.11 0.36
11.1
3.2
-0.13 0.03
0.20
1890
20.5
2.4
0.17 0.36 0.57
17.6
2.7
0.05 0.29 0.53
14.6
3.0
-0.14 0.16 0.45
11.7
3.2
-0.24 -0.04 0.30
2265
21.7
2.4
0.20 0.41 0.65
18.5
2.7
0.06 0.33 0.60
15.4
3.0
-0.16 0.19 0.53
12.2
3.2
-0.34 -0.09 0.43
35 KW - LCH120H4B with HUMIDITROL
®
DEHUMIDIFICATION
OPERATING (2ND STAGE)
Entering
Wet
Bulb
Temper-
ature
Total
Air
Volume
Outdoor Air Temperature Entering Outdoor Coil
18.3°C
23.8°C
29.4°C
35°C
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Dry Bulb
Dry Bulb
Dry Bulb
Dry Bulb
L/s
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
17.2°C
1510
27.9
4.8
.63
.78
.86
25.4
5.4
.61
.79
.91
22.8
6.0
.58
.82
.95
20.1
6.6
.55
.82
1.00
1890
30.6
4.9
.66
.83
.93
27.6
5.5
.64
.81
.95
24.6
6.1
.63
.79
.98
21.7
6.7
.62
.79
1.00
2265
33.6
4.9
.69
.82
.99
30.0
5.5
.70
.82
1.00
26.5
6.1
.70
.82 1.00
22.8
6.7
.69
.82
1.00
19.4°C
1510
31.8
4.9
.47
.60
.74
29.0
5.5
.44
.59
.76
26.1
6.1
.41
.59
.79
23.3
6.7
.38
.58
.80
1890
34.2
5.0
.49
.64
.79
31.1
5.6
.46
.63
.80
28.1
6.2
.43
.62
.78
25.0
6.7
.41
.61
.76
2265
36.8
5.0
.50
.67
.80
33.3
5.6
.48
.66
.79
30.1
6.2
.45
.66
.78
26.9
6.8
.44
.65
.78
21.7°C
1510 35.4
5.0
.30 .42 .55 32.4
5.6
.26
.41
.54 29.4
6.2
.23 .38 .52 26.5
6.8
.21
.35
.51
1890 38.0
5.1
.31 .45 .59 34.8
5.7
.27
.43
.58 31.8
6.3
.23 .39 .56 28.8
6.8
.20
.38
.56
2265 40.3
5.1
.32 .47 .62 37.2
5.7
.27
.45
.61 34.1
6.3
.24 .41 .61 31.2
6.8
.20
.39
.60
44 KW - LCH150H4B with HUMIDITROL
®
DEHUMIDIFICATION
OPERATING (1ST STAGE)
Entering
Wet
Bulb
Temper-
ature
Total
Air
Volume
Outdoor Air Temperature Entering Outdoor Coil
18.3°C
23.8°C
29.4°C
35°C
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Dry Bulb
Dry Bulb
Dry Bulb
Dry Bulb
L/s
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
17.2°C
1795
14.9
3.0
0.50 0.74 0.96
12.3
3.3
0.41 0.69 0.96
9.7
3.6
0.26 0.64 0.97
7.3
3.9
0.35
0.54
0.99
2075
15.6
3.0
0.55 0.82 1.00
12.8
3.3
0.46 0.81 1.00
10.1
3.6
0.32 0.78 1.00
7.3
3.9
0.23
0.73
1.00
2360
16.4
3.1
0.59 0.90 1.00
13.4
3.4
0.53 0.91 1.00
10.4
3.6
0.34 0.76 0.90
7.5
3.9
0.11
0.90
1.00
19.4°C
1795
17.1
3.1
0.30 0.50 0.70
14.5
3.4
0.21 0.42 0.66
11.8
3.7
0.04 0.33 0.62
9.2
4.0
0.03
0.12
0.55
2075
17.9
3.1
0.33 0.53 0.78
15.1
3.4
0.22 0.48 0.76
12.2
3.7
0.05 0.38 0.73
9.4
4.0
-0.04 0.20
0.70
2360
18.7
3.2
0.34 0.57 0.85
15.6
3.4
0.25 0.53 0.84
12.7
3.7
0.08 0.44 0.84
9.7
4.0
-0.10 0.26
0.64
21.7°C
1795
19.4
3.2
0.15 0.32 0.49
16.7
3.5
0.05 0.24 0.44
13.8
3.8
-0.10 0.12 0.37
11.1
4.1
-0.28 -0.07 0.23
2075
20.1
3.2
0.16 0.34 0.53
17.2
3.5
0.05 0.25 0.47
14.4
3.8
-0.11 0.14 0.41
11.5
4.1
-0.30 -0.06 0.28
2360
20.8
3.3
0.16 0.36 0.58
17.9
3.5
0.05 0.29 0.53
15.0
3.8
-0.12 0.17 0.48
12.1
4.1
-0.30 -0.04 0.35
44 KW - LCH150H4B with HUMIDITROL
®
DEHUMIDIFICATION
OPERATING (2ND STAGE)
Entering
Wet
Bulb
Temper-
ature
Total
Air
Volume
Outdoor Air Temperature Entering Outdoor Coil
18.3°C
23.8°C
29.4°C
35°C
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Dry Bulb
Dry Bulb
Dry Bulb
Dry Bulb
L/s
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
17.2°C
1795
32.8
6.4
0.65 0.83 0.96
29.6
7.1
0.64 0.85 0.99
26.4
7.8
0.63 0.87 1.00
23.1
8.4
0.62
0.88
1.00
2075
34.0
6.4
0.69 0.87 0.97
30.5
7.1
0.69 0.88 1.00
27.1
7.8
0.69 0.87 1.00
23.8
8.5
0.68
0.85
1.00
2360
35.2
6.5
0.73 0.88 0.99
31.8
7.2
0.74 0.86 1.00
28.1
7.8
0.73 0.87 1.00
24.4
8.5
0.73
0.88
1.00
19.4°C
1795
36.9
6.6
0.49 0.64 0.80
33.4
7.3
0.44 0.63 0.81
29.8
7.9
0.43 0.64 0.83
26.4
8.6
0.42
0.62
0.85
2075
38.0
6.6
0.50 0.67 0.84
34.4
7.3
0.48 0.67 0.85
30.7
8.0
0.46 0.65 0.88
26.9
8.6
0.43
0.65
0.85
2360
39.3
6.7
0.52 0.69 0.87
35.3
7.3
0.50 0.70 0.87
31.4
8.0
0.49 0.69 0.85
27.6
8.7
0.46
0.69
0.85
21.7°C
1795
40.8
6.7
0.32 0.45 0.59
37.0
7.4
0.28 0.43 0.59
33.3
8.1
0.23 0.40 0.58
29.5
8.8
0.20
0.39
0.58
2075
42.0
6.8
0.32 0.47 0.63
37.9
7.5
0.28 0.45 0.62
34.2
8.2
0.24 0.43 0.62
30.4
8.8
0.20
0.40
0.63
2360
43.4
6.9
0.32 0.50 0.67
39.2
7.5
0.28 0.47 0.67
35.2
8.2
0.24 0.45 0.67
31.2
8.8
0.20
0.43
0.66
Содержание Energence LCH