background image

3

When the protection equipment starts, please shut down the 
manual power switch, and restart operation after problem is
solved.

NOTE

3.2 About power cut

If power is cut during operation, stop all the operation immediately.

Power comes again. The lamp on the display panel of indoor unit 

flashes. And then unit will auto-restart.

Mishandling in operation:

If mishandling happens because of lighting or mobile wireless, 

please shut off the manual power switch, and turn on again, then

push the ON/OFF button.

3.3 Heating capacity

The heating operation is a heat-pump process that heat will be 

absorbed from outdoor air and released in doors. Once the 

outdoor temperature is decreased, heating capacity decreased 

corredpindingly.

Other heating equipment is suggested to be used together when 

outdoor temperature is too low.

In some extreme cold upland that buy another inddoor unit 

equipped electrical heater will obtain better performance.(Refer 

to indoor unit owner’s manual for details)

NOTE

The motor in Indoor Unit will continue running for 20~30 seconds 

for to remove residual heat when the Indoor Unit recoeiving OFF

command during heating operation.

If the air conditioner malfunction occurs because of disturb, 

pleasereconnect the air conditioner to power, then turn on it 

again.

1.

2.

A protection feature prevents the air conditioner from being 

activated for approximately 5 minuites when it restarts 

immediately after operation.

The indoor unit of the intelligent inverter centralized air 

conditioner can be controlled solely, but the indoor unit in the 

same system can not run cooling and heating at the same time.

3.6 Features of heating operation

Warm air will not be blown out immediately at the beginning of 

the heating operation, 3~5 minutes ago (depends on the indoor 

and outdoor temperature), until the indoor heat exchanger 

become hot, then blows out warm air.

During operation, the fan motor in the outdoor unit may stop 

running under high temperature.

During Fan Operation, if other Indoor Units are running on 

Heating Mode, the fan may stop in order to prevent sending 

heat  wind.

3.7 Defrost in the heating operation

During heating operation, outdoor unit sometimes will frost. To 

increase efficiency, the unit will start defrosting automatically 

(about 2~10 minutes), and then water will be drained out from

outdoor unit.

During defrosting, both the fan motors in the outdoor unit and

indoor unit will stop running.

When the Cooling and Heating operation confront with each 

other, the Indoor Unit which are running on Cooling Mode would

stop and there will be Standby or No Priority displayed in the 

Control Panel. Those Indoor Units which are running on Heating

Mode will run continuously. 

If  the Air Conditioner Administrator has set running mode, 

then the air conditioner  can not run on modes other than the 

presetted.Standby or No Priority will be displayed in the 

Control Panel.

3.4 Five-minute protection feature

3.5 Cooling and heating operation

Содержание e-Lite LV-MO280

Страница 1: ...LV MO280 335 OM 20 04 E e Lite DC INVERTER FREE LV MO280 335 Installation Manual...

Страница 2: ......

Страница 3: ...m the air conditioner you purchased depend on model The actual shape shall prevail NOTE This air conditioner comprises an indoor unit outdoor unit and a connection pipe Outdoor unit Air outlet 1 2 3 4...

Страница 4: ...lt in injury or damage to the equipment Failure to observe a warning may result in death The appliance shall be installed in accordance with national wiring regulations Do not use the air conditioner...

Страница 5: ...ldren without supervision When capacity of indoor unit greater than the sum of 100 capacity of indoor unit will be attenuated When capacity of indoor unit greater than or equal to the sum of 120 in or...

Страница 6: ...nuites when it restarts immediately after operation The indoor unit of the intelligent inverter centralized air conditioner can be controlled solely but the indoor unit in the same system can not run...

Страница 7: ...overable Recoverable Irrecoverable Recoverable Recoverable Recoverable Recoverable Recoverable Recoverable Recoverable P8 F1 E1 High pressure protection M HOME for the indoor and outdoor units does no...

Страница 8: ...h sound is heard when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the syste...

Страница 9: ...tdoor unit and indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Out...

Страница 10: ...IMER ON indicator goes off after a lapse of certain time Check whether the timer operation is started when the TIMER ON is indicated on the display Up to the set time the air conditioner will automati...

Страница 11: ...he unit if the power fluctuations exceed the allowed range Frequent collisions and vibrations The air may contain dust salt harmful gas or oil such as sulphite and hydrogen sulphide Frequent on and of...

Страница 12: ...and dimensions are subject to change without notice and without incurring liability Improper installation adjustment alteration service or maintenance can cause property damage or personal injury Ins...

Отзывы: