Page 43
BLOWER DATA
SLP98UH070V36B BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Heating Input Range and Blower Volume - CFM
35%
40%
50%
60%
70%
80%
90%
100%
Increase (+15%) Heat CFM
489
538
636
735
833
931
1030
1128
Increase (+7.5%) Heat CFM
450
496
588
680
772
864
956
1048
Default Heat CFM
410
453
539
624
710
796
881
967
Decrease (-7.5% ) Heat CFM
380
419
498
578
657
736
815
895
Decrease (-15% ) Heat CFM
349
385
458
531
604
676
749
822
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Blower Speed Selections
First Stage Cool Speed - cfm
Second Stage Cool Speed - cfm
Low
Medium-
Low
Medium
High
High
(Default)
Low
Medium-
Low
Medium
High
High
(Default)
Increase (+10%) Cool CFM
600
740
840
970
860
1060
1215
1365
Default Cool CFM
555
665
770
855
810
960
1130
1265
Decrease (-10%) Cool CFM
500
600
680
790
705
840
1005
1140
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
icomfort Touch™ Communicating Thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times
- 35%, 60%, 80%, 100% (four-stage) with time delays in-between
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage COOL speed position
minimum 300 cfm.
Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 250 cfm.
SLP98UH090V36C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Heating Input Range and Blower Volume - CFM
35%
40%
50%
60%
70%
80%
90%
100%
Increase (+15%) Heat CFM
687
734
827
921
1014
1108
1201
1295
Increase (+7.5%) Heat CFM
654
697
782
867
953
1038
1123
1209
Default Heat CFM
621
660
737
814
891
968
1045
1122
Decrease (-7.5% ) Heat CFM
581
616
687
757
828
899
970
1041
Decrease (-15% ) Heat CFM
540
572
637
701
766
830
895
959
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Blower Speed Selections
First Stage Cool Speed - cfm
Second Stage Cool Speed - cfm
Low
Medium-
Low
Medium
High
High
(Default)
Low
Medium-
Low
Medium
High
High
(Default)
Increase (+10%) Cool CFM
625
710
830
950
875
1040
1210
1360
Default Cool CFM
565
670
760
860
800
945
1100
1240
Decrease (-10%) Cool CFM
520
610
685
785
720
840
970
1115