background image

Page 1

INTRODUCTION

 The CompleteHeat

TM

Combination Heating System

Congratulations on the purchase of your Lennox CompleteHeat system.
Lennox takes pride in manufacturing high quality products that keep you
comfortable while saving you energy and money.

The  CompleteHeat  system  is  a  highĆefficiency  combination  waterĆ  and
spaceĆheating system. The system consists of an air module (AM30) and a
heating module (HM30). The two units work together to provide warm air like
a furnace and hot potable water like a hot water heater. The CompleteHeat sysĆ
tem takes care of these needs while being up to 40% more efficient than stanĆ
dard furnaces and water heaters.

This booklet explains how the CompleteHeat system operates, how to identify
the unit model number, how to operate a typical thermostat and how to mainĆ
tain the system for optimum performance. Keep this booklet and the warranty
shipped with the CompleteHeat system for future reference.

Thank you again for choosing Lennox.

All manuals and user guides at all-guides.com

Содержание CompleteHeat

Страница 1: ...N HEATING SYSTEM PRODUCT LITERATURE 1997 Lennox Industries Inc Litho U S A SYSTEM OPERATION MAINTENANCE SAFETY CONSIDERATIONS 503 718M 6 98 Supersedes 8 97 All manuals and user guides at all guides co...

Страница 2: ...30 The two units work together to provide warm air like a furnace and hot potable water like a hot water heater The CompleteHeat sys tem takes care of these needs while being up to 40 more efficient t...

Страница 3: ...at dial Combustion products travel out of the heat exchanger condensate water is drained and exhaust gases are vented safely to the outdoors Hot water is directed from the HM30 to faucets shower heads...

Страница 4: ...and 4 out of children s reach Vapors 1 cannot be seen 2 are heavier than air 3 go a long way on the floor and 4 can be carried from other rooms to the heater by air currents FOR YOUR SAFETY Do not sto...

Страница 5: ...t force 6 Turn on all electrical power to system 7 Set room thermostat and water temperature dial to desired settings NOTE When unit is initially started steps 1 through 7 may need to be repeated to p...

Страница 6: ...tat does not have ON or CONT settings and the continuous fan option is desired ask your dealer about an optional continuous fan switch In high humidity areas the continuous fan operation tends to incr...

Страница 7: ...ves These valves help reduce the risk of scalding KEEPING YOUR SYSTEM IN TOP FORM HM30 Tank Draining Procedure It is recommended that 5 to 10 gallons of water from the HM30 tank be drained every six m...

Страница 8: ...is in the air module it may be inside the unit behind an access panel or located on the side of the unit in an external filter rack If replacement is necessary always replace it with the same type of...

Страница 9: ...me caution when discharging valve Re placement of T P valve should be done by a trained professional or a licensed plumb ing contractor T P valve testing should be done annual ly Remove HM30 top acces...

Страница 10: ...d be in the ON position 4 Replace any blown fuses or reset circuit breakers 5 Air filter should be clean To keep your heating and cooling system running in peak operating condition year after year con...

Отзывы: