background image

Page 6

506071−01 02/08

Displaying Outside Temperature

Pressing the ENTER (Outside) button at the HOME
screen displays the outside temperature (see figure 15) for
several seconds, then returns to room temperature.

88

Fan

Settings

Hold

Enter

(Outside)

Figure 15. Check Outside Temperature

SETTINGS − Filter/Maintenance Reminders

The L3722C thermostat is designed to remind you when
the filter needs changing or when routine maintenance is
required, as (and if) defined, by you. These optional re-
minders are not enabled until you activate them. To do so,
press the SETTINGS button once or twice for the desired
reminder as shown in figure 16 and as described in table 1.

FILTER

OFF

MAINTENANCE

For FILTER, press SETTINGS
button 1 time

For MAINTENANCE, press
SETTINGS button 2 times

Figure 16. Reminder Settings Display

The default setting for the reminders is OFF (disabled).
Press Up/Down arrow buttons to select the desired re-
minder intervals.

Table 1. Filter and Maintenance Reminders

Buttons to

Use

Reminder

Available Settings and
How to Use

Settings

(1st press)

FILTER

Total fan run time expressed in
months (Off 1 3 6 12); for

(1st press)

then 

Arrows

to scroll

months (Off, 1, 3, 6, 12); for
example, if fan runs 12 hours a day,
1 month reminder displays in 2

to scroll

selections

1 month reminder displays in 2
calendar months.

Settings

(2nd press)

then 

Arrows

MAINTE-

NANCE

Elapsed chronological time in
months (Off, 6, 12). Use this, for
example, to remind yourself when to

then 

Arrows

to scroll

selections

example, to remind yourself when to
perform routine checks or when to
call a technician for perodic

selections

call a technician for perodic
preventive maintenance.

Enter

Stores settings.

NOTE − The HOME screen will reappear about 15 seconds
after the final arrow button press. OR, press the ENTER
button at any time to store any changes and exit to the
HOME screen.

After either programmed interval has elapsed, the remind-
er will be displayed as shown in figure 17.

COOL

OFF

AUTO

EMG.

HEAT

I0:26

PROG  
A B C D

HOLD

FAN 

ON

AUTO

FILTER  SERVICE
MAINTENANCE

76

ROOM

°

MO

AM

PM

COOL

OFF

AUTO

EMG.

HEAT

FAN 

ON

AUTO

FILTER  SERVICE
MAINTENANCE

76

Service

Indicator

Flashing

ROOM

°

Filter &

Maintenance

Indicators

Figure 17. Reminders

After the filter has been changed or maintenance per-
formed, reset the reminder by pressing the SETTINGS
button for 4 seconds at the corresponding reminder set-
tings screen. The screen will blink for a few moments to in-
dicate that the timer has been reset.

Service Indicator

When abnormal equipment operation is detected, the
SERVICE indicator will flash on the screen (see figure 17).
This indicates that the equipment requires service from a
qualified service technician.

Thermostat RESET

Under some abnormal conditions, it may be necessary to
reset" the thermostat to its default condition. Such a RE-
SET would delete all programming and settings and there-
fore should only be used on rare occasions when the the
thermostat fails to function as designed and/or as pro-
grammed. Such an instance can occur as a result of a pow-
er surge or similar electrical disturbance (e.g. after an elec-
trical storm or power outage). The RESET button can be
used to recover from this situation.

CAUTION

When the RESET button is pressed, ALL settings re-
vert back to the defaults, including the default pro-
gram (see tables 3 and 4).

The RESET button is an unlabeled, recessed button lo-
cated behind the door on the right−hand side of the thermo-
stat, below the SETTINGS button (see figure 3). Use a pa-
per clip or small pencil to press the RESET button; ALL
thermostat settings will be reset to the defaults listed in the
Default Thermostat Settings section.

Содержание ComfortSense L3722C

Страница 1: ...rogram 6 FAN Controlling Fan Operation 5 Displaying Outside Temperature 6 SETTINGS Filter Maintenance Reminder 6 Service Indicator 6 Thermostat RESET 6 Removing Installing Thermostat 7 Default Thermostat Settings 7 Thermostat Output Table 7 Technical Specifications 7 General These instructions are intended as a general guide and do not supersede local codes in any way Consult authorities having ju...

Страница 2: ...seconds or the HOME screen will re turn Heat Prog Fan Settings Cool Day Time Hold Enter DOOR OPEN Auto Copy Outside Figure 3 Thermostat Buttons When an Arrow HOLD HEAT or COOL button is pressed SETPOINT and the temperature setting appears for 15 seconds If desired start making changes within 15 sec onds or the HOME screen will return The backlight will turn off 15 seconds after the HOME screen rea...

Страница 3: ...during a demand NOTE Heating equipment is activated for at least 3 min utes if no buttons are pressed during the demand interval COOL Using the Cool Mode Enabling and Disabling Cool Mode Use the COOL button to enable or disable cool mode as desired If the thermostat is in heat or off mode cool mode is enabled when the COOL button is pressed This is indi cated by COOL on the right side of the displ...

Страница 4: ...oint is displayed to the right of the actual room temperature Each button press adjusts the setpoint up or down by 1 degree After the desired setpoint is reached the HOME screen will reappear after about 15 seconds Permanent Hold Mode At any time the program is running from the HOME screen set a permanent hold program override by press ing the HOLD button see figure 9 The thermostat now functions ...

Страница 5: ...g to repeat the same program for other days A Press the PROG button then press the COPY button The display clears the screen except for Copy from MO with MO flashing Press the COPY button again to copy Monday s program B The display changes to Copy to MO Use the ar row buttons to scroll to the desired day where you want the same program as Monday Press the COPY button C Repeat steps A and B for as...

Страница 6: ...onds after the final arrow button press OR press the ENTER button at any time to store any changes and exit to the HOME screen After either programmed interval has elapsed the remind er will be displayed as shown in figure 17 COOL OFF AUTO EMG HEAT I0 26 PROG A B C D HOLD FAN ON AUTO FILTER SERVICE MAINTENANCE 76 ROOM MO AM PM COOL OFF AUTO EMG HEAT FAN ON AUTO FILTER SERVICE MAINTENANCE 76 Servic...

Страница 7: ... is above setpoint 0 5F but below setpoint 1 5F AND 30 minute upstage timer HAS NOT expired With a LARGE cool demand temperature is above setpoint 1 5F OR 30 minute upstage timer HAS expired Default Thermostat Settings Default thermostat settings are in table 3 and the default program is shown in table 4 Table 3 Default Thermostat Settings Mode Heat Perm Hold Heat Setpoint Perm Hold 70 F or 21 C C...

Страница 8: ...me elapsed time between any furnace activation next furnace activation 6 minutes Minimum elapsed time between any compressor activa tion and the next compressor activation 6 minutes NOTE All protection timers except the compressor OFF timer can be over ridden if a heating or cooling demand is initiated or terminated using the UP DOWN HEAT or COOL buttons Equipment Protection Override Both the mini...

Отзывы: