WARNING: Read this manual before carrying out installation, repair or maintenance work.

TABLE OF CONTENTS

POINTS TO BEAR IN MIND 

 

        PAGE 

2

DATA PAGE FOR COMMISSIONING OF THE UNIT                                 

 

 

PAGE 3

1.- GENERAL CHARACTERISTICS 

  

                  

 

 

             

 PAGE

1.1.- PHYSICAL DATA
1.2.- ELECTRICAL DATA 
1.3.- FAN PERFORMANCE
1.4.- UNIT DIMENSIONS

2.- 

2.- 

INSTALLATION 

          

PAGE

2.1.- INSTALLATION GUIDELINES
2.2.- OPTIONAL TASK PRIOR TO UNIT INSTALLATION:
        REGULATING AIRFLOW IN THE FANS
2.3.- SERVICE SPACE
2.4.- DRAINAGE
2.5.- REFRIGERANT CONNECTIONS
2.6.- ELECTRICAL CONNECTIONS
2.7.- INSTALLATION OF OPTIONS

3.- COMMISSIONING AND OPERATION             

 

 

 

 

 

 PAGE

3.1.- PRELIMINARY CHECKS

4.- MAINTENANCE      

  

 

 

 

 

 

 

 

 

 PAGE

4.1.- PREVENTIVE MAINTENANCE
4.2.- FAULT DIAGNOSIS 

Lennox have been providing environmental solutions since 1895. Our COMPACTAIR / AIRCOOLAIR range continues 

to meet the standards that have made LENNOX a household name; flexible design solutions to meet your needs and 

uncompromising attention to detail; engineered to last, simple to maintain and quality that comes as standard. For 

information on local contacts go to www.lennoxeurope.com.

All the technical and technological information contained in this manual, including any drawings and technical descrip-

tions provided by us, remain the property of Lennox and must not be utilised (except in the operation of this product), 

reproduced, issued to or made available to third parties without the prior written agreement of Lennox.

Содержание CIC 020S

Страница 1: ...lennoxemeia com AIRCOOLAIR COMPACTAIR CIC CIH Installation operating and maintenance Indoor unit MIL121E 0613 06 2013 Translation of original manual...

Страница 2: ...E 3 1 PRELIMINARY CHECKS 4 MAINTENANCE PAGE 4 1 PREVENTIVE MAINTENANCE 4 2 FAULT DIAGNOSIS Lennox have been providing environmental solutions since 1895 Our COMPACTAIR AIRCOOLAIR range continues to me...

Страница 3: ...arizing the user with the equipment reproduced photocopied transferred or transmitted to third parties without prior written authorization from Lennox Data published in the operating instructions are...

Страница 4: ...ATA INPUT COLD CYCLE HEATING CYCLE ELECTRIC POWER CONSUMPTION Amps Fan indoor section Options Installed Comments Fan indoor section UNIT INSTALLER TEL INSTALLER CONTROL PANEL IDENTIFICATION CODE INSTA...

Страница 5: ...3 10 14 3 10 14 3 15 21 5 15 21 5 15 21 5 15 21 5 15 21 5 20 28 6 20 28 6 20 28 6 20 28 6 20 28 6 27 39 27 39 M 400V 3 50 1 GENERAL CHARACTERISTICS 1 1 PHYSICAL DATA Type of unit COMPACTAIR AIRCOOLAIR...

Страница 6: ...136 105 75 45 070S 070D rpm 937 888 838 788 738 m3 h 12450 237 200 163 128 95 13550 183 145 109 73 14650 124 85 48 15090 115 75 36 085D rpm 937 888 838 788 738 m3 h 14000 202 163 125 87 51 15125 182 1...

Страница 7: ...17350 323 279 236 196 157 18875 310 264 221 180 140 20400 296 248 204 162 121 22450 178 133 90 120D rpm 837 792 748 704 659 m3 h 19300 295 249 206 163 123 21000 278 231 186 142 101 22700 258 209 163 1...

Страница 8: ...7 391 329 268 208 15090 450 383 320 258 196 085D rpm 1172 1109 1047 985 923 m3 h 14000 452 390 328 268 211 15125 438 371 307 245 183 16250 418 349 282 215 150 16725 408 338 270 202 135 100D rpm 937 88...

Страница 9: ...14650 641 561 484 408 336 15090 636 555 477 400 328 085D rpm 1339 1268 1197 1126 1055 m3 h 14000 636 557 478 406 336 15125 623 542 464 387 315 16250 609 526 445 367 289 16725 602 518 436 357 279 100D...

Страница 10: ...1 380 380 725 343 340 337 330 684 305 300 297 287 644 268 263 257 245 603 232 227 220 205 21000 22700 24750 766 380 380 373 725 340 337 330 684 300 297 287 644 263 257 245 603 227 220 205 r p m m3 h 1...

Страница 11: ...ccess to motor Drainage outside thread 3 4 VERTICAL DISCHARGE OPTIONAL Refrigerant connections Electrical power supply HORIZONTAL DISCHARGE STANDARD Access to motor Air filter VERTICAL DISCHARGE OPTIO...

Страница 12: ...it should be Elastic Joints Avoid the use of BYPASS joints between the extraction air and input air in both the outdoor and indoor sections The structure where the unit is placed must be able to suppo...

Страница 13: ...M n 80mm Inspection and cleaning cap 2 5 REFRIGERANT CONNECTIONS The unit is supplied with gas and liquid lines sealed with copper caps THE UNITS ARE SUPPLIED WITH NITROGEN GAS THIS MUST BE REMOVED B...

Страница 14: ...IRCUIT BREAKERS ARE OPEN IN ORDER TO CARRY OUT THE ELECTRICAL CONNECTIONS FOLLOW THE ELECTRICAL DIAGRAM SUPPIED WITH THE UNIT CONNECTION OF CONTROL ELEMENTS VOLTAGE OPERATING LIMITS 342 462V To connec...

Страница 15: ...igh points in the system In order to drain the system check that drain valves have been installed at all low points of the system MS INDOOR UNIT EF IU MS IU RS MS IU EF EF Exhaust fan MS Mixing sectio...

Страница 16: ...Shielded 2x1 Shielded 5x1 Shielded ELECTRICAL BOX DS Discharge sensor OS Outdoor sensor AS Remote ambient sensor RS Duct sensor RS HR T Duct remote sensor CO2 CO2 Air quality probe DPT Air differentia...

Страница 17: ...INDOOR UNIT RETURN AIR DUCT DISCHARGE AIR RETURN SECTION AIR FILTER 5x1 Shielded 2x1 Shielded 2x1 Shielded 5x1 Shielded 3x1 Shielded 3x1 Shielded 2x1 Shielded ELECTRICAL BOX MIXING SECTION DM Damper...

Страница 18: ...95 L B F G H I 1 2 2 N D E M 35 24 2 INSTALLATION MODELS 060S 070S 055D 070D 085D INDOOR UNIT SECTION OF FLEXIBLE DUCT TO BE INSTALLED BY THE CUSTOMER 2100 x 698mm2 OUTDOOR AIR DAMPER MIXING SECTION D...

Страница 19: ...IT OUTDOOR AIR DAMPER MIXING SECTION DISCHARGE FRAME 803x1008x40 EXHAUST FAN OPTION RETURN AIR INDOOR UNIT OUTDOOR AIR DAMPER RETURN DAMPER RETURN AIR SECTION OF FLEXIBLE DUCT TO BE INSTALLED BY THE C...

Страница 20: ...S 100D 120D 140D DIMENSIONS FREE COOLING WITH RETURN FAN INDOOR UNIT SECTION OF FLEXIBLE DUCT TO BE INSTALLED BY THE CUSTOMER 2275 x 1010 mm2 SECTION OF FLEXIBLE DUCT TO BE INSTALLED BY THE CUSTOMER 2...

Страница 21: ...PREVENTIVE MAINTENANCE HELPS TO AVOID COSTLY REPAIRS SO PERIODIC INSPECTIONS ARE REQUIRED GENERAL CONDITION OF THE HOUSING Fittings paintwork damage from knocks rust spots levelling and supporting con...

Страница 22: ...y the detector activates an alarm but only if the fan is ON SMOKE DETECTOR In this case it would initiate shutdown sequence the unit fully close the return air damper and open the fresh air dam per up...

Страница 23: ...22 NOTES...

Страница 24: ...MBOURG FRANCE GERMANY ITALY NETHERLANDS POLAND PORTUGAL Due to Lennox s ongoing commitment to quality the specifications ratings and dimensions are subject to change without notice and without incurri...