Page 7
Table 2. CBX25UHV‐018 Air Handler Performance (0 through 0.80 in. w.g. External Static Pressure Range)
ADJUST
Jumper
Setting
BDC3 Jumper Speed Position
HEAT Speed
First-Stage COOL Speed
Second-Stage COOL Speed
1
2
3
4
1
2
3
4
1
2
3
4
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
+
470
670
890
1080
350
470
620
760
470
675
890
1090
NORM
440
615
810
1000
350
450
560
700
435
610
815
1020
-
400
560
730
910
350
420
520
650
400
575
725
915
NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First-stage cooling air volume is approximately 70% of the second-stage COOL speed setting.
. . . . . . . .
Continuous fan speed is approximately 50% of second-stage COOL speed setting.
. . . . . . . .
Lennox Harmony III
®
Zone Control Applications - Minimum air handler speed is approximately 250 cfm .
. . . . . . . .
Table 3. CBX25UHV‐024 Air Handler Performance (0 through 0.80 in. w.g. External Static Pressure Range)
ADJUST
Jumper
Setting
BDC3 Jumper Speed Positions
HEAT Speed
First-Stage COOL Speed
Second-Stage COOL Speed
1
2
3
4
1
2
3
4
1
2
3
4
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
+
470
690
900
1120
350
470
625
775
480
670
890
1125
NORM
430
640
810
1020
330
450
580
720
430
605
820
1020
-
410
550
720
900
300
405
505
650
390
545
740
930
NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First-stage cooling air volume is approximately 70% of the second-stage COOL speed setting.
. . . . . . . .
Continuous fan speed is approximately 50% of second-stage COOL speed setting.
. . . . . . . .
Lennox Harmony III
®
Zone Control Applications - Minimum air handler speed is approximately 250 cfm.
. . . . . . . .
Table 4. CBX25UHV‐030 Air Handler Performance (0 through 0.80 in. w.g. External Static Pressure Range)
ADJUST
Jumper
Setting
BDC3 Jumper Speed Positions
HEAT Speed
First-Stage COOL Speed
Second-Stage COOL Speed
1
2
3
4
1
2
3
4
1
2
3
4
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
+
650
900
1100
1320
430
600
740
920
650
875
1100
1330
NORM
590
795
1000
1200
390
550
680
830
580
800
1000
1200
-
520
730
895
1075
340
475
620
750
500
700
900
1090
NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First-stage cooling air volume is approximately 70% of the second-stage COOL speed setting.
. . . . . . . .
Continuous fan speed is approximately 50% of second-stage COOL speed setting.
. . . . . . . .
Lennox Harmony III
®
Zone Control Applications - Minimum air handler speed is approximately 250 cfm.
. . . . . . . .
Table 5. CBX25UHV‐036 Air Handler Performance (0 through 0.80 in. w.g. External Static Pressure Range)
ADJUST
Jumper
Setting
BDC3 Jumper Speed Positions
HEAT Speed
First-Stage COOL Speed
Second-Stage COOL Speed
1
2
3
4
1
2
3
4
1
2
3
4
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
+
880
1115
1345
1435
615
770
930
1090
880
1110
1340
1435
NORM
800
1010
1215
1425
555
695
845
990
795
1005
1215
1420
-
715
905
1095
1275
505
625
755
885
715
905
1090
1280
NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First-stage cooling air volume is approximately 70% of the second-stage COOL speed setting.
. . . . . . . .
Continuous fan speed is approximately 50% of second-stage COOL speed setting.
. . . . . . . .
Lennox Harmony III
®
Zone Control Applications - Minimum air handler speed is approximately 250 cfm.
. . . . . . . .
Table 6. CBX25UHV‐042 Air Handler Performance (0 through 0.80 in. w.g. External Static Pressure Range)
ADJUST
Jumper
Setting
BDC3 Jumper Speed Positions
HEAT Speed
First-Stage COOL Speed
Second-Stage COOL Speed
1
2
3
4
1
2
3
4
1
2
3
4
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm
+
1115
1345
1560
1800
800
960
1120
1265
1130
1360
1580
1800
NORM
1025
1215
1415
1630
730
870
1020
1150
1040
1240
1450
1640
-
925
1110
1280
1460
650
790
915
1050
950
1120
1290
1470
NOTES - The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First-stage cooling air volume is approximately 70% of the second-stage COOL speed setting.
. . . . . . . .
Continuous fan speed is approximately 50% of second-stage COOL speed setting.
. . . . . . . .
Lennox Harmony III
®
Zone Control Applications - Minimum air handler speed is approximately 450 cfm.
. . . . . . . .