  7

3.2.9  Smoking – Causes and Troubleshooting 

To reduce the likelihood of smoking when opening the door, set the combustion air controls 
to the left before opening the door.  Your fireplace has been designed and tested to provide 
smoke free operation.  Occasionally, there may be a small amount of smoking upon lighting 
the fire, until the chimney heats up but this should not continue.  If the fireplace continues to 
smoke it is probably for one of the following reasons: 

 
A.  Negative pressure in the house 

 

As the fire burns, air goes up the chimney.  This air must be replaced through leakage 
into the house or through the outside air duct.  When operating the BRENTWOOD, open 
a nearby window temporarily to check if there is adequate air supply replacement. 

 

B.  Fans operating (e.g.: range hood) 

 

These fans draw air out of the house and may actually cause a negative pressure in the 
house.  Turn off all fans and open a nearby window to determine if this is the cause of the 
problem. 

 

C.  Wet wood  

 

Wet or tarred wood will smoulder and smoke instead of burn properly. 

 

D.  Dirty or blocked chimney 

 

Check to make sure the chimney is clear and clean. 

 

E.  Chimney not long enough 

 

The minimum chimney height is 12 ft. not including the fireplace height.  The chimney 
must extend at least 3 feet (915 mm) above its point of contact with the roof and at least 2 
feet (610 mm) higher than any roof or wall within 10 feet (3 m) of it.  When installed 
with offsets, the minimum chimney height is 15 ft.  Additional height will increase 
draught and will decrease the tendency to smoke. 

 

F.  Poor chimney draft 

 

With no fire, there should be sufficient draught to exhaust cigarette smoke introduced 
under the baffle.  Chimneys installed against an outside wall without protection may 
generate back draught problems which will cause start-up problems.  To prevent this, 
open a nearby window, roll up a piece of paper and light it.  Then, hold it in the upper 
part of the firebox to warm up the chimney.  Wait until the draught is sufficient, then start 
the fire. 

 

G.  Blower for central forced air kit operating 

 

Make sure that the blower is at the "off" position when you open the fireplace door for 
reloading. 

Содержание BRENTWOOD

Страница 1: ...y modification or alteration of construction may void the warranty listings and approvals of this system In that case Lennox Heart product will not be responsible for damages Install the fireplace onl...

Страница 2: ...inish Door Casing Care 3 3 6 Ashes 3 3 7 Refractory Installation 3 3 8 Door Installation 3 3 9 Door Adjustment 3 3 10 Glass Care Replacement 3 3 11 Glass Care Cleaning 3 3 12 Gasket Replacement 3 4 FI...

Страница 3: ...locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled Caution Never use gasoline kerosene charcoal lighter fluid or similar liquids to start or re...

Страница 4: ...2 2 CERTIFICATION LABEL...

Страница 5: ...cribed in these instructions and using only Lennox Hearth Products components The BRENTWOOD is not intended for use with a gas log Failure to follow these instructions will void the certification and...

Страница 6: ...the fireplace make sure to remove the plastic wrapping on the door Remove all remaining glue with mild soap The first 5 or 6 fires should be small fires of short duration about 30 to 60 minutes This...

Страница 7: ...lished the control can be pushed forward to shut down the air boost allowing for a longer burn time The combustion air control should be in the closed position primary air and air boost when the firep...

Страница 8: ...or This method of burning should be used only after operating the BRENTWOOD with the air control opened to produce a hot fire for about an hour or at medium pace for at least 3 hours Slow combustion c...

Страница 9: ...t wood Wet or tarred wood will smoulder and smoke instead of burn properly D Dirty or blocked chimney Check to make sure the chimney is clear and clean E Chimney not long enough The minimum chimney he...

Страница 10: ...mulation is large a creosote fire in the chimney can damage the chimney and overheat the surrounding wood framing Creosote formation in a chimney can be minimized by making sure there is always visibl...

Страница 11: ...tion air controls 2 Alert your family of the possible danger 3 If you require assistance alert your fire department 4 If possible use a dry chemical fire extinguisher baking soda or sand to control th...

Страница 12: ...left side refractory 4 Remove the right side refractory 5 Remove the back refractory 6 Remove the front ceramic baffle 7 Remove the rear ceramic baffle To install the new refractories follow the abov...

Страница 13: ...rols closed the glass will tend to get dirty unless the fuel firebox and glass are maintained at hot temperatures see Refuelling For Best Performance To clean the glass there are a number of specially...

Страница 14: ...is needed for the fireplace The adequacy of the floor can be checked by first estimating the weight of the fireplace system Weights are given in the appendix Next measure the area occupied by the fire...

Страница 15: ...unning from floor to ceiling see figure 8 If combustible facing is to be used position the studs back from the front edge of the fireplace a space the thickness of the facing material so that the faci...

Страница 16: ...14 INSULATED CHASE CONSTRUCTION Figure 10...

Страница 17: ...on the fireplace i e the steel fa ade of the fireplace figure 11 2 Non combustible materials such as brick stone or ceramic tile may project in front of and onto the fireplace facing figure 12 Mantel...

Страница 18: ...ing 2 30 deg elbows back to back on the fireplace See components list page 30 The only fan that can be used with the gravity kit is the UZY3 The gravity kit allows you to block the upper louver of the...

Страница 19: ...extend the single outlet it is necessary to install the insulation strip provided with the system A maximum of 3 89 mm of extension is provided by the single outlet system see figure 16 When installi...

Страница 20: ...or mantel 5 When traversing a combustible wall or floor a firestop must be installed at the wall or floor penetration The hole size must be 13 X 13 330 mm x 330 mm 6 Do not connect the hot air ducts...

Страница 21: ...house The air intake must not draw air from the attic from the basement or garage D The air intake should be installed where it is not likely to be blocked by snow or exposed to extreme wind and away...

Страница 22: ...contained in the following kit ACZIB 1 Install the outside air kit box and collar on the top of the unit Install the flex 4 adaptor on the top of the outside air kit box 2 Install the outside air reg...

Страница 23: ...eight is 12 ft 3 7 m In altitude add 18 450 mm to the chimney for every 2000 feet 600 m above sea level 5 All chimney installations must include at least one support The maximum length of chimney that...

Страница 24: ...place turn of a turn clockwise Continue installing chimney lengths making sure to lock each length in place 4 Every time the chimney passes through a ceiling or a wall install the appropriate firestop...

Страница 25: ...23 AC CHIMNEY INSTALLATION AIR COOLED GALVALUME CHIMNEY Figure 24...

Страница 26: ...26 Table 2 ROOF DOWN SLOPE HOLE SIZE SLOPE AC Roof Pitch 6 0 15 380 mm 2 12 15 3 8 390 mm 4 12 16 1 8 410 mm 6 12 16 7 8 430 mm 8 12 18 1 4 465 mm 10 12 19 5 8 500 mm 12 12 21 3 8 545 mm CROSS SLOPE H...

Страница 27: ...to the elbow to the surrounding frame using nails or drywall screws 2 Install the necessary chimney lengths to achieve the required offset Lock the chimney lengths together If penetrating a wall use a...

Страница 28: ...26 Table 4...

Страница 29: ...ed firestop or wall radiation shield must be installed Only one is required In cold climate locations we recommend that you use the insulated wall radiation shield since it will maintain the home s th...

Страница 30: ...all this support may be used on the wall to support the chimney The maximum heights are given in Table 6 For offset support installation refer to the instructions provided with the support CHIMNEY MOD...

Страница 31: ...29 Figure 29...

Страница 32: ...H0480 Support section AC 6SL H0481 Roof support XST H0482 Roof brace XBS2 H0483 Wall band XBM H0484 Firestop Telescopic attic radiation shield ACRST H0498 Firestop AC BF H0485 Radiation shield AC RS...

Страница 33: ...6 lengths 1 decorative brass frame and 1 brass louver 7B26ZKSB 1 H0503 Black grill with support 7B30ZO H0504 Brass grill for 7B30ZK 7B30ZGB H0505 1 brass louver 1 decorative brass frame 7B26ZKSLB H05...

Страница 34: ...ireplace with any material Except the wood framing See page 13 Figure 8 Chimney 2 50 mm Mantel 45 1143 mm measured from the base of the fireplace REPLACEMENT PARTS Baffle refractory 2 pieces PR ISO220...

Отзывы: