 6 -

White Rodgers 36E Gas Valve - 

Switch gas valve lever

to 

OFF

. See figure 2.

Honeywell VR8205 Gas Valve - 

Turn knob on gas valve

clockwise

 to  

OFF

. Do not force. See figure 3.

WHITE RODGERS 36E SERIES GAS VALVE

GAS VALVE SHOWN IN OFF POSITION

FIGURE 2

ON

OFF

HONEYWELL VR8205 SERIES GAS VALVE

GAS VALVE SHOWN IN OFF POSITION

FIGURE 3

 7 - Wait five (5) minutes to clear out any gas. If you then

smell  gas, 

STOP

!  Immediately  call  your  gas  supplier

from  a  neighbor's  phone.  Follow  the  gas  supplier's

instructions. If you do not smell gas go to next step.

 8 -

White Rodgers 36E Gas Valve - 

Switch gas valve lever

to 

ON

.

Honeywell  VR8205  Gas  Valve  - 

Turn  knob  on  gas

valve counterclockwise

 

 

to 

ON

.  Do not force.

 9 - Replace the access panel.
10 - Turn on all electrical power to unit.
11 - Set thermostat to desired setting.

NOTE – When unit is initially started, steps 1 through 11
may need to be repeated to purge air from gas line.

12 - If  the  appliance  still  will  not  operate,  follow  the

instructions To Turn Off Gas To Unit" and call your

service technician or gas supplier.

To Turn Off Gas To Unit

 1 - Set thermostat to lowest setting.
 2 - Turn off all electrical power to unit if service is to be

performed.

 3 - Remove the access panel.
 4 - Switch lever on White Rodgers gas valve to 

OFF

; turn

knob on Honeywell valve clockwise

 to  

OFF

. Do not

force.

 5 - Replace the access panel.

Filters

80MGF series units are equipped with external filters

which  should  be  inspected  monthly  and  replaced

when necessary to assure proper furnace operation.

See table 1 for filter sizes. Replacement filters used

with 80MGF-40/60/75 units must have a minimum veĆ

locity  rating  of  400  FPM.  Replacement  filters  used

with  80MGF-100/120/140  units  require  a  minimum

velocity rating of 625 FPM. Figures 4, 5, and 6 show

possible filter locations.

TABLE 1

FILTER SIZE

MODEL NUMBER

UPFLOW

DOWNFLOW

1 FILTER

2 FILTERS

80MGF-45/60/75

16 in. X 20 in. X 1 in. 16 in. X 20 in. X 1 in.

80MGF-100/120/140

20 in. X 20 in. X 1 in. 16 in. X 20 in. X 1 in.

UPFLOW FURNACE

BOTTOM RETURN AIR

FIGURE 4