Page 2
SPECIFICATIONS
General
Data
Model No.
13ACD−018 13ACD−024 13ACD−030 13ACD−036 13ACD−042 13ACD−048
(−1, −2 units)
13ACD−060
Nominal Tonnage
1.5
2
2.5
3
3.5
4
5
Connections
(
t)
Liquid line o.d. − in.
3/8
3/8
3/8
3/8
3/8
3/8
3/8
(sweat)
Suction line o.d. − in.
3/4
3/4
3/4
7/8
7/8
7/8
1-1/8
1
Refrigerant (R-22) furnished
4 lbs. 0 oz.
4 lbs. 8 oz.
5 lbs. 5 oz. 6 lbs. 15 oz. 6 lbs. 15 oz. 9 lbs. 8 oz.
(12 lbs 12oz)
13 lbs. 6 oz.
Outdoor
C il
Net face area
ft
Outer coil
13.22
15.11
13.22
13.22
15.11
18.67
(24.50)
24.50
Coil
- sq. ft.
Inner coil
− − −
− − −
12.60
12.60
14.40
17.96
(23.56)
23.56
Tube diameter − in.
5/16
5/16
5/16
5/16
5/16
5/16
5/16
Number of rows
1
1
2
2
2
2
2
Fins per inch
22
22
22
22
22
22
22
Outdoor
F
Diameter − in.
18
18
18
18
18
22
22
Fan
Number of blades
3
3
4
4
4
4
4
Motor hp
1/5
1/5
1/5
1/5
1/3
1/4
1/4
Cfm
2500
2500
2450
2450
2930
3670
(3830)
3830
Rpm
1100
1100
1100
1100
1100
825
825
Watts
200
200
200
200
310
315
(330)
330
Shipping Data
− lbs. 1 package
122
129
150
150
177
191
(233)
236
ELECTRICAL DATA
Line voltage data − 60 hz − 1ph
208/230V
208/230V
208/230V
208/230V
208/230V
208/230V
208/230V
2
Maximum overcurrent protection (amps)
15
20
30
30
45
40
60
3
Minimum circuit ampacity
10.7
14.1
18.7
19.1
25.9
25.7
33.3
Compressor
Rated load amps
7.7
10.4
14.1
14.4
19.2
19.2
26.1
p
Power factor
.98
.96
.96
.96
.98
.94
.96
Locked rotor amps
40.0
54.0
67.0
77.0
104.0
97.0
141.0
Condenser
F
M t
Full load amps
1.0
1.0
1.0
1.0
1.9
1.7
1.7
Fan Motor
Locked rotor amps
1.9
1.9
1.9
1.9
4.1
3.1
3.1
OPTIONAL ACCESSORIES − must be ordered extra
Compressor Crankcase
H
t
93M04
p
Heater
93M05
Compressor Hard Start Kit
10J42
p
81J69
Compressor Low Ambient Cut−Off 45F08
Compressor Sound Cover
69J03
Compressor Time−Off Control 47J27
Freezestat
3/8 in. tubing
93G35
5/8 in. tubing
50A93
Hail Guards
92M88
92M89
12W21
92M94
High Pressure Switch Kit
94J46
Indoor Blower Off Delay
Relay
58M81
Loss of Charge Switch Kit
84M23
Low Ambient Kit
24H77
Mounting Base
69J06
g
69J07
Refrigerant
Line Sets
L15−41−20, L15−41−30,
L15−41−40, L15−41−50
L15−65−30, L15−65−40,
L15−65−50
Field Fabricate
Unit Stand−Off Kit
94J45
NOTE Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Refrigerant charge sufficient for 15 ft. length of refrigerant lines.
2
HACR type circuit breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.