ALCOVE DIMENSIONS -  DIMENSIONS – ALCOVE

MAXIMUM DEPTH / PROFONDEUR MAXIMUM 35”(889mm)

MINIMUM WIDTH / LARGEUR MAXIMUM 51”(1295mm)

MINIMUM HEIGHT / HAUTEUR MAXIMUM 46”(1168mm)

SEE OWNER’S MANUAL FOR OTHER ALCOVE 

CLEARANCE CONFIGURATIONS.

RÉFÉREZ VOUS AU MANUEL D’INSTALLATION 

POUR TOUT AUTRE DÉGAGEMENT REQUIS.

HEARTH PROTECTION

SEE INSTRUCTION MANUAL.

PROTECTIONS AU PLANCHER : RÉFÉREZ 

VOUS AU MANUEL D’INSTALLATION.

* 16.5” (1295Mm) to sidewall in an alcove 

* Dégagement des matériaux 

  Combustible pour les murs de côté 

  Dans une alcôve est 16.5 Po (1295mm)

  De chaque côté.

MINIMUM CLEARANCES TO COMBUSTIBLES IN INCHES

DÉGAGEMENTS AUX COMBUSTIBLES - POUCES

2"

(51mm)

*15"

(381mm)

Co

m

bu

sti

ble

 W

all

Mur Combustible

VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL

MAY BE INSTALLED IN RESIDENTIAL BEDROOMS AND MANUFACTURED (MOBILE) HOMES.

TESTED TO ANSI Z21.88-2005/CSA 2.33-2005 “VENTED GAS FIREPLACE HEATERS”, UL307b, CSA P.4.1-02, AND CGA 2.17-M91.

THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY.  IF NOT, FOLLOW THE CURRENT ANSI 

Z223.1/NFPA 54-LATEST EDITION (USA) OR CAN/CGA  B149.1-LATEST EDITION (CANADA)

 AND SAFETY STANDARD, TITLE 24 CFR, 

PART 3280 FOR MOBILE HOMES.  ALSO, APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S 

INSTALLATION INSTRUCTIONS.

THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN 

AN AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL CODES. 

SEE OWNER’S MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES, UNLESS A 

CERTIFIED KIT IS USED.

DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.

IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. 

IF NOT, FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22-1-LATEST 

EDITION (CANADA).

VENTING: THIS APPLIANCE  MUST  BE  PROPERLY  CONNECTED  TO A  VENTING  SYSTEM  IN ACCORDANCE  WITH  THE 

MANUFACTURER’S INSTRUCTIONS. SEE MANUFACTURER’S INSTALLATION INSTRUCTIONS FOR APPROVED PIPE BRANDS 

AND PIPE SEALING PROCEDURES.

FOR ALTITUDES ABOVE 2,000 FT/610M (IN CANADA 4500 FT/1370M) DE-RATE THE APPLIANCE BY FOUR (4)% FOR EVERY 1,000 

FT (405 M).
THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS.

Part No./ No. Pièce #36242 Rev. B, 2/08 

 

DO NOT REMOVE OR COVER THIS LABEL 

MADE IN U.S.A.

CAUTION:

  HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP 

CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS 

AWAY. KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING 

INSTRUCTIONS ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS 

APPLIANCE ONLY. DO NOT OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. 

REPLACEMENT OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN 

CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED 

WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED 

INSTALLER, SERVICE AGENCY OR GAS SUPPLIER.

ALCOVE OR PARALLEL / 

POSITION PARALLÈLE OU 

POSITION DE L'ALCÔVE

CORNER / 

POSITION

EN COIN

MANUFACTURED BY / FABRIQUÉ PAR:

LENNOX HEARTH PRODUCTS

PO BOX 987

AUBURN, WA., USA 98071

MODEL 

  VISION™ 35

MODÈLE

Report No. / Número de Rapport

050-S-16b-5

SERIAL

 NO.

FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.

CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT 

CETTE ÉTIQUETTE, C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.

RATINGS

Model VISION 35

Model VISION 25

NATURAL GAS

LP GAS

NATURAL GAS

LP GAS

MAX/MIN INPUT BTUH 0-2,000 FT (0-610 M)*

35,000/23,000

35,000/23,500

25,000/17,500

25,000/18,000

MANIFOLD PRESSURE (IN. WC)

3.5

10.0

3.5

10.0

MIN. INLET PRESSURE (IN. WC)

5.0

11

5.0

11

ORIFICE (DMS) 0-2,000 FT (0-610 M)*

#34/.111 IN.

#50/.070 IN.

#42/.093 IN.

#53/.059 IN.

*UNIT FACTORY EQUIPPED FOR 0-2000 FT/0-610 M, IN CANADA 0-4500 FT/0-1370 M

ELECTRICAL RATING: 120 VAC, 60 HZ, LESS THAN 2 AMPS

DATE OF MANUFACTURE / DATE DE FABRICATION

2008

2010

2011

2009

JANV

JAN

FEVR

FEB

MARS

MAR

AVR

APR

MAI

MAY

JUIN

JUN

JUIL

JUL

AOÛT

AUG

SEPT

SEP

OCT

OCT

NOV

NOV

DEC

DEC

90°

    5-5/8”

(143mm)

10”

(254mm)

10”

(254mm)

8-7/8”

 (225mm)

Co

mb

ust

ible

 Wa

ll

Mur C

omb

ustib

le

HOMOLOGUÉ FOYER RADIANT PRÉFABRIQUÉ AU 

GAZ -NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE

MAY BE INSTALLED IN RESIDENTIAL BEDROOMS AND MANUFACTURED (MOBILE) HOMES.
TESTÉ SELON LA NORME ANSI Z21.88-2005/CSA 2.33-2005 «FOYER RADIANT AU GAZ», UL307B, CSA P.4.1-02, ET CGA 2.17-M91.
CET APPAREIL DOIT ÊTRE INSTALLÉ CONFORMÉMENT AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION 

ANSI NFPA 54-DERNIÈRE ÉDITION (ETATS-UNIS), OU CAN/CGA-B149.1-DERNIÈRE ÉDITION (CANADA)

 

POUR LES MAISON MOBILE 

LE STANDARD DE SÉCURITÉ EST TITLE 24CFR, PART 3280 .  CET APPAREIL DOIT ÊTRE INSTALLER SELON LES SPÉCIFICATIONS 

DU MANUFACTURIER.
CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TYPE DE GAZ INDIQUÉ SUR LA PLAQUE SIGNALÉTIQUE ET PEUT ÊTRE INSTALLÉ 

DANS UNE MAISON PRÉUSINÉE OU DANS UNE MAISON MOBILE FIXE, LÀ OÙ LES CODES RÉGIONAUX LE PERMETTENT. VOIR LE 

MANUEL D’ENTRETIEN POUR PLUS DE DÉTAILS. CET APPAREIL NE PEUT PAS ÊTRE CONVERTI POUR L’USAGE AVEC D’AUTRES 

TYPES DE GAZ À MOINS D’UTILISER UNE TROUSSE DE CONVERSION HOMOLOGUÉE.
DANGER: RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHEZ L’APPAREIL AVANT D’EN FAIRE L’ENTRETIEN.
SI L’APPAREIL REQUIERT UN BRANCHEMENT ÉLETRIQUE, LES RACCORDEMENTS ET LA MISE À LA TERRE DOIVENT ÉTRE 

CONFORMES AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI/NFPA 70 OU CSA C22-1.

CONDUIT:  CET  APPAREIL  DOIT  ÊTRE  INSTALLER  SEULEMENT  AVEC  UN  CONDUIT  D’ÉVACUATION 

RECOMMANDÉ PAR LE MANUFACTURIER.  TOUJOURS SE RÉFÉRER AU MANUEL D’INSTALLATION.
EN ALTITUDE, AU-DELÀ DE 2000 PI/610 M, (AU CANADA 0-4500 PI/0-1370M) LA CAPACITÉ ÉNERGÉTIQUE DE 

L’APPAREIL DIMINUE DE QUATRE (4)% POUR CHAQUE 1000 PI (405 M).
CE FOYER RADIANT AU GAZ À ÉVACUATION N’EST PAS CONÇU POUR ÊTRE UTILISÉ AVEC DES FILTRES À AIR.

DANGER:

 CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE 

INSTALLÉ À L’ÉCART DES ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX. 

SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS LA PIÈCE. GARDEZ LA ZONE AUTOUR DU 

FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES VAPEURS ET LIQUIDES 

INFLAMMABLES. MAINTENEZ LE BRÛLEUR ET LE BOÎTIER DES COMMANDES PROPRE EN TOUT 

TEMPS. VOIR LES MANUELS D’INSTALLATION ET D’ENTRETIEN QUI ACCOMPAGNENT L’APPAREIL. 

SEUL LE PANNEAU VITRÉ FOURNI PAR LE MANUFACTURIER PEUT ÊTRE UTILISÉ AVEC CET APPAREIL. 

EN AUCUN CAS, L’APPAREIL NE PEUT ÊTRE UTILISÉ SANS LA VITRE OU AVEC LA VITRE BRISÉE. LE 

REMPLACEMENT DE LA VITRE DOIT ÊTRE EFFECTUÉ PAR UN TECHNICIEN DE SERVICE QUALIFIÉ.
AVERTISSEMENT: UNE  INSTALLATION  INADÉQUATE  DE  MÊME  QU’UN  AJUSTEMENT,  UNE 

MODIFICATION,  UNE  RÉPARATION  OU  UN  ENTRETIEN  INCORRECTS  PEUVENT  CAUSER  DES 

BLESSURES OU DOMMAGES À LA PROPRIÉTÉ. RÉFÉREZ-VOUS AU MANUEL D’ENTRETIEN LIVRÉ AVEC 

CET APPAREIL. POUR DE L’ASSISTANCE, CONSULTEZ UN INSTALLATEUR QUALIFIÉ, UNE ENTREPRISE 

DE SERVICE OU UN FOURNISSEUR DE GAZ.

SPÉCIFICATIONS

Modèle VISION 35

Modèle VISION 25

GAZ NATUREL

GAZ PROPANE

GAZ NATUREL

GAZ PROPANE

ENTRÉE MAX/MIN BTU/HR 0-4500 pi (0-1370 

M)*

35000/23000 35000/23500 25000/17500

25000/18000

PRESSION À LA SORTIE  (IN. WC/C.E.)

3.5

10.0

3.5

10.0

PRESSION MINIMUM D’ENTRÉE DU GAZ 

(IN. WC/C.E.)

5.0

11

5.0

11

ORIFICE (DMS) 0-4500 pi (0-1370 M)*

#34/.111"

#50/.070"

#42/.093"

#53/.059"

* L’APPAREIL PRÉUSINÉ EST MUNI D’ÉQUIPEMENT POUR 0-2000 PIEDS (0-610 M). AU CANADA 0-4500 PIEDS (0-1370M).

SPÉCIFICATIONS ÉLECTRIQUE 120 VCA, 60 HZ, MOINS DE 2 AMPÈRES 

NE PAS RETIRER CETTE ÉTIQUETTE         

Fabriqué aux  U.S.A. 

IGN  08-0710

Poêle

Poêle

Stove

Stove

SAFETY / LISTING LABEL - VISN-25/35 AND SDVSS-25/35

2011     2012    2013     2014

US

Portland

Содержание VISION SDVSS-25

Страница 1: ...vez les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz AVERTISSEMENT Assurez vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d incindie ou d explosion ...

Страница 2: ...3 Residential and Mobile Home Installations 13 Vent Considerations 13 Vent Parts List 14 Horizontal Vent Installation 14 Vertical Vent Installation 15 Flue Restrictors 15 Horizontal Terminations 16 Vertical Terminations 16 Horizontal Vent Termination Locations 17 Gas Line Installation 18 Gas Pressure Requirements 18 LP and Natural Gas Supplies 18 Installer Attaching Safety In Operation Warnings 19...

Страница 3: ...taller service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to this appliance and or its operating controls is danger ous WARNING Clothing or other flammable material should not be placed on or near the appliance AVERTISSEMENT On ne devrait pas placer de vêtem...

Страница 4: ...o a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance is only for use with the type of gas indicated on rating plate This appliance is not convertible for use with other gases unless a certified kit is used Cet appareil doit être utilisé uniquement avec les types de gaz in...

Страница 5: ...stato de pared quecontrolalachimenea verifiquequeelinterruptor opera la chimenea encendiéndola y apagándola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared Figura B Seleccione el idioma que más se habla en la casa 2 Si se usa un control remoto para controla...

Страница 6: ...se with either natural gas or propane Is not for use with solid fuels Is approved for sitting rooms and or bedrooms THE GAS STOVE ORIFICE SIZE ALTITUDE ADJUSTMENT For altitudes above 2 000 feet In Canada 4 500 FT 1370 M the orifice should be de rated by 4 for every 1 000 feet to maintain the proper ratio of gas to air Improper orifice sizing may result in damage and unsafe conditions Changingtheor...

Страница 7: ...unded and wired in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition or the Canadian Electrical Code CSA C22 1 latest edition NEW YORK CITY NEW YORK MEA COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS Massachusetts Approval G3 0806 6 These appliances are approved for installation in the US state of Mas sachusetts if the following ...

Страница 8: ...the minimum clearance to combustibles from the rear of the unit to the wall It is also important to note the thickness of the wall Before cutting the vent hole through the wall make sure that ALL vent and termination clearances see Page 17 will be met Electrical The standard fan motor requires 120 Volts AC for operation The stove is not dependent on the fan or an outside electrical supply to opera...

Страница 9: ...rth Products warranty will be voided if one of the fol lowing occurs Installation of any damaged stove or vent system component Unauthorized modification of the direct vent system Installation other than as instructed by Lennox Hearth Products Security Chimneys or Simpson Dura Vent Installation of any stove or vent system component not manufac turedorapprovedbyLennoxHearthProducts SecurityChimneys...

Страница 10: ...inches millimeters Corner Installation Alcove dimensions The minimum width between the alcove side walls is 51 1295mm The minimum height of the alcove is 46 1168mm and the maximum depth is 35 889mm Floor Protection A non combustible hearth pad is not required This stove may be installed on a combustible surface as long as the combustible material such as carpeting does not extend 1 1 2 38 mm verti...

Страница 11: ...ts or they will snap the studs off To install the spring handle first close the door and screw the handle into the receiving nut Then spray a household glass cleaner or water on the shaft of the handle to act as a lubricant Next twist the spring handle counterclockwise onto the shaft Use a household glass cleaner or alcohol to remove any fingerprints prior to firing the stove INSTALLATION Conversi...

Страница 12: ...he logs are not properly installed your appliance will not function correctly Parts list rear log right log left log center log brick panel packaged separately 1 Remove the logs from the box and carefully unwrap them The logs are fragile so handle them with care 2 Remove the brick retainer bracket from the upper left corner inside the stove Log Inserts 5 Place ember material rockwool over ports Th...

Страница 13: ...on of the direct vent system Installation of any vent component part not approved or manufactured by the approved vent manufacturer Installation other than as instructed by Lennox Hearth Products and vent manufacturers instructions Residential and Mobile Home Installations These are the minimum pieces required Other parts may be required for your particular installation Minimum Components for Hori...

Страница 14: ...tion Venting terminals may not be recessed into a wall or siding 1 Set the unit in the desired location Check whether or not wall studs are in the way when the venting system is attached If wall studs are in the way you may want to adjust the location of the unit 2 Assemble the desired combination of pipe and elbow to the appliance adaptor with pipe seams facing down Offsetting the pipe seams as d...

Страница 15: ...wing page and note which restrictor setting is recommended The flue restrictor is shipped in the firebox of your stove To install the restrictor see Figure 18 Remove the two 5 32 allen head screws A below Using pliers repeatedly bend the unwanted portion of the flue restrictor and discard Install the flue restrictor using the two 5 32 allen head screws according to the diagram below Install the fl...

Страница 16: ...SS 35 LP 0 3 horizontal 14 Snorkel Required No Light Obstructor VISN 35 SDVSS 35 NG 0 3 horizontal 14 Snorkel Required No Light Obstructor Offsets must remain within maximum and minimum lines To install the stove with pipe directly out the back a snorkel is not required for VISN 25 SDVSS 25 gas stoves A snorkel is required for the VISN 35 SDVSS 35 gas stoves See Pages 14 and 15 for snorkel install...

Страница 17: ...ded above meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly I Clearance to service regulator vent outlet 3 feet 91 cm 3 feet 91 cm J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 6 in 15 2 cm for appliances 10 000...

Страница 18: ...ght of the inlet tap To check manifold pressure with the appliance burning at the high burn setting insert a small flat bladed screwdriver into the tap and turn a half turn counterclockwise Cover the tap with the line from the manometer and check the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution retighten if n...

Страница 19: ...ôle le fonctionnement du foyer en le faisant basculerdeMarcheàArrêt etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour éliminer la poussière et les traces de graisse ou d huile Collez l étiquette sur la surface de la plaque de l interrupteur mural qui contrôle le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principaleme...

Страница 20: ...ice technician Force or attempted repair may result in a fire or explosion D DO NOT use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety information on this page before proceeding 2 If appli...

Страница 21: ...cause the flames to turn orange sooner may result in poor combustion sooting and a hazardous situation See the drawing to the right showing proper flame appearance When testing for proper operation If an optional thermostat is installed adjust it to its highest temperature setting Visually determine that main burner gas is burning properly i e no floating lifting or flashback Adjust the primary ai...

Страница 22: ...e sound of rush ing air may be heard The blower sounds may be reduced by adjusting the speed control located on the blower assembly Also a slight clicking soundmaybeheardasthegasvalveorblowerswitchisturnedonandoff Paint Curing This stove has been painted with Stove Bright high temperature metallic paint It leaves the factory dry to the touch but completes the curing process as the stove is used To...

Страница 23: ...sing the thermostat or remote control and set the thermostat or remote control to the lowest temperature when you wish to use the rocker switch only otherwise one may override the other Millivolt Control System This stove operates on a millivolt control system As such no additional power supply is needed for the stove to heat The pilot assembly contains a thermocouple that when heated by the pilot...

Страница 24: ...mopile and thermocouple and extend across the main burner tube ports Be careful not to back the screw out of its threads o Check that the area around the stove is kept clear and is free of combustible materials gasoline and other flammable vapors and liquids o Check the millivolt system as per the table on this page Millivolt and System Checks Check Test To Test Connect Meter Leads to Terminals Th...

Страница 25: ...eaner with ammonia on the door and glass gasket as it may dis solve the gasket glue Repair If the glass is broken in the glass door the entire door metal frame gasket and glass should be replaced as a unit This replacement glass door is available from your Lennox Hearth Products dealer Do not use substitute parts or materials The glass is neo ceramic and alterna tive types must not be used NOTE BE...

Страница 26: ...rocess 2 Remove the log set see Log Installation 3 Remove the two phillips head screws from the back of the burner 4 Lift the right end of the burner and slide if off the orifice and shutter tube Remove the burner from the firebox 5 Remove the labeled cover through which the valve control knobs protrude by removing the two screws securing it and slide it off the valve knobs 6 Mark and disconnect w...

Страница 27: ...in pilot position for 1 2 minutes and light Check for spark at electrode and pilot if no spark and electrode wire is properly connected replace igniter See Lighting Instructions Pilot will not stay lit after carefully following lighting instructions Pilot flame is not sur rounding thermocouple Thermocouple not generating sufficient voltage Air in gas supply line Check pilot flame adjustment see Ma...

Страница 28: ... l entretien des commandes étiquetez tous les fils avant de les débrancher Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux POWER CORD SNAP SWITCH GRN 6 SPEED CONTROL SWITCH BLOWER BLK 6 RED 12 RED 7 RED 8 BLK 16 8 MALE SPADE 1 4 FEMALE SPADE 1 4 RING LUG CRIMP FEMALE SPADE 1 4 STRIP OUTER JACKET 6 W H T 6 2 PL FEMALE SPADE 1 4 FEMALE SPADE 1 4 MALE SPADE 1 4 FEMAL...

Страница 29: ...so requires 75265 conversion kit H6034 Burner Assembly H5922 Pilot Assembly NG or LP H5942 Gas Control Valve NG if LP also requires H5945 LP Regulator H5943 Regulator NG H5945 Regulator LP H5966 Orifice Main Burner 42 NG 25 000 BTU H5967 Orifice Main Burner 34 NG 35 000 BTU H5964 Orifice Main Burner LP 53 25 000 BTU H5970 Orifice Main Burner LP 50 35 000 BTU H3071 Blower H5875 Blower Snap Switch H...

Страница 30: ...ch Up Paint Kit H8159 TSPK B Touch Up Paint Metallic Black 12 oz aerosol Controls H4635 DWTK Wall Thermostat Digital H0251 RCL STAT Remote Control Deluxe Thermostat DC ref form 750129M 70005 RT AC Remote Control Thermostat AC ref form 775280M Wall Thermostat Remote Control Product Reference Information Cat No Description Ship Weight Ship Volume 55107C VISN 25 35 Direct Vent Freestanding Gas Stove ...

Страница 31: ...0 23 500 25 000 17 500 25 000 18 000 MANIFOLD PRESSURE IN WC 3 5 10 0 3 5 10 0 MIN INLET PRESSURE IN WC 5 0 11 5 0 11 ORIFICE DMS 0 2 000 FT 0 610 M 34 111 IN 50 070 IN 42 093 IN 53 059 IN UNIT FACTORY EQUIPPED FOR 0 2000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS DATE OF MANUFACTURE DATE DE FABRICATION 2008 2010 2011 2009 JANV JAN FEVR FEB MARS MAR AV...

Страница 32: ...urnisseur de gaz Si vous opérez cet appareil sans qu il ne soit correctement raccordé à un conduit d évacuation vous pourriez risquer d être empoisonné au monoxyde de carbone CO ce qui pourrait entraîner des conséquences grave ou la mort POUR COUPER L ALIMENTATION EN GAZ DE L APPAREIL 1 Pour arrêter le brûleur mettre l interrupteur à la position OFF ou ajustez le thermostat à une température en de...

Страница 33: ...33 NOTES ...

Страница 34: ...s for future refer ence Product reference information We recommend that you record the following important information aboutyourappliance PleasecontactyourLennoxHearthProductsdealer for any questions or concerns For the number of your nearest Lennox Hearth Products dealer please call 1 800 9 LENNOX Replacement parts See Page 29 for a complete replacement parts list Use only parts sup plied from th...

Отзывы: