Lennox Hearth Products VISION SDVSS-25 Скачать руководство пользователя страница 1

INSTALLER:  Leave this manual with the appliance.

CONSUMER:  Retain this manual for future reference.

INSTALLATEUR:  Laissez cette notice avec l'appareil.

CONSOMMATEUR:  Conservez cette notice pour consul-

tation ultérieure.

- Do not store or use gasoline or other flammable vapors and 

liquids in the vicinity of this or any other appliance.

- WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 

•  Do  not  touch  any  electrical  switch;  do  not  use  any 

phone in your building. 

• Immediately call your gas supplier from a neighbor’s 

phone.  Follow the gas supplier’s instructions. 

•  If  you  cannot  reach  your  gas  supplier,  call  the  fire 

department.

-   Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

WARNING:  If the information in these instructions is 

not followed exactly, a fire or explosion may result 

causing property damage, personal injury or death.

- Ne  pas  entreposer  ni  utilizer  d’essence  ni  d’autres 

vapeurs ou liquides inflammables dans le voisinage 

de cet appareil ou de tout autre appareil.

- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

• Ne pas tenter d’allumer d’appareil.

• Ne touchez à aucan interrupteur. Ne pas vous servir 

des téléphones se trouvant dans le bâtiment où vous 

trouvez. 

•  Appelez  immédiatement  votre  fournisseur  de  gaz 

depuis un voisin. Suivez les instructions du fournis-

seur. 

• Si vous ne pouvez rejoindre le fournisseur de gaz, 

appelez le service des incindies.

- L’installation et l’entretien doivent être assurés par un 

installateur ou un service d’entretien qualifié ou par 

le fournisseur de gaz.

AVERTISSEMENT:  Assurez-vous de bien suivre les 

instructions données dans cette notice pour réduire 

au minimum le risque d’incindie ou d’explosion ou 

pour éviter tout dommage matériel, toute blessure 

ou la mort.

INSTALLATION AND OPERATION

Ce manuel d’installation est disponible en francais, s  implement en faire 
la demande. Numéro de la pièce 775222CF.

MODELS

US

Portland

P/N 775222M  REV. F  09/2011

DIRECT

-

VENT

VISION™

This appliance may be installed in an aftermarket permanently located, manufactured  home (USA only) or mobile 

home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating 

plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

WARNING AVERTISSEMENT

UNE SURFACE VITRÉE CHAUDE PEUT 

CAUSER DES BRÛLURES.

LAISSER REFROIDIR LA SURFACE 

VITRÉE AVANT D'Y TOUCHER.

NE PERMETTEZ JAMAIS À UN ENFANT 

DE TOUCHER LA SURFACE VITRÉE.

HOT GLASS WILL

 CAUSE BURNS.

DO NOT TOUCH GLASS

 UNTIL COOLED.

NEVER ALLOW CHILDREN TO 

TOUCH GLASS.

VISN-25/35   

SDVSS-25/35

This Gas Stove is factory equipped for 35,000 BTU input and can be converted to 

25,000 using a smaller orifice (provided in optional orifice kit P/N H5966).

OTL Report No. 050-S-16b-5

Содержание VISION SDVSS-25

Страница 1: ...vez les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz AVERTISSEMENT Assurez vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d incindie ou d explosion ...

Страница 2: ...3 Residential and Mobile Home Installations 13 Vent Considerations 13 Vent Parts List 14 Horizontal Vent Installation 14 Vertical Vent Installation 15 Flue Restrictors 15 Horizontal Terminations 16 Vertical Terminations 16 Horizontal Vent Termination Locations 17 Gas Line Installation 18 Gas Pressure Requirements 18 LP and Natural Gas Supplies 18 Installer Attaching Safety In Operation Warnings 19...

Страница 3: ...taller service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to this appliance and or its operating controls is danger ous WARNING Clothing or other flammable material should not be placed on or near the appliance AVERTISSEMENT On ne devrait pas placer de vêtem...

Страница 4: ...o a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance is only for use with the type of gas indicated on rating plate This appliance is not convertible for use with other gases unless a certified kit is used Cet appareil doit être utilisé uniquement avec les types de gaz in...

Страница 5: ...stato de pared quecontrolalachimenea verifiquequeelinterruptor opera la chimenea encendiéndola y apagándola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared Figura B Seleccione el idioma que más se habla en la casa 2 Si se usa un control remoto para controla...

Страница 6: ...se with either natural gas or propane Is not for use with solid fuels Is approved for sitting rooms and or bedrooms THE GAS STOVE ORIFICE SIZE ALTITUDE ADJUSTMENT For altitudes above 2 000 feet In Canada 4 500 FT 1370 M the orifice should be de rated by 4 for every 1 000 feet to maintain the proper ratio of gas to air Improper orifice sizing may result in damage and unsafe conditions Changingtheor...

Страница 7: ...unded and wired in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition or the Canadian Electrical Code CSA C22 1 latest edition NEW YORK CITY NEW YORK MEA COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS Massachusetts Approval G3 0806 6 These appliances are approved for installation in the US state of Mas sachusetts if the following ...

Страница 8: ...the minimum clearance to combustibles from the rear of the unit to the wall It is also important to note the thickness of the wall Before cutting the vent hole through the wall make sure that ALL vent and termination clearances see Page 17 will be met Electrical The standard fan motor requires 120 Volts AC for operation The stove is not dependent on the fan or an outside electrical supply to opera...

Страница 9: ...rth Products warranty will be voided if one of the fol lowing occurs Installation of any damaged stove or vent system component Unauthorized modification of the direct vent system Installation other than as instructed by Lennox Hearth Products Security Chimneys or Simpson Dura Vent Installation of any stove or vent system component not manufac turedorapprovedbyLennoxHearthProducts SecurityChimneys...

Страница 10: ...inches millimeters Corner Installation Alcove dimensions The minimum width between the alcove side walls is 51 1295mm The minimum height of the alcove is 46 1168mm and the maximum depth is 35 889mm Floor Protection A non combustible hearth pad is not required This stove may be installed on a combustible surface as long as the combustible material such as carpeting does not extend 1 1 2 38 mm verti...

Страница 11: ...ts or they will snap the studs off To install the spring handle first close the door and screw the handle into the receiving nut Then spray a household glass cleaner or water on the shaft of the handle to act as a lubricant Next twist the spring handle counterclockwise onto the shaft Use a household glass cleaner or alcohol to remove any fingerprints prior to firing the stove INSTALLATION Conversi...

Страница 12: ...he logs are not properly installed your appliance will not function correctly Parts list rear log right log left log center log brick panel packaged separately 1 Remove the logs from the box and carefully unwrap them The logs are fragile so handle them with care 2 Remove the brick retainer bracket from the upper left corner inside the stove Log Inserts 5 Place ember material rockwool over ports Th...

Страница 13: ...on of the direct vent system Installation of any vent component part not approved or manufactured by the approved vent manufacturer Installation other than as instructed by Lennox Hearth Products and vent manufacturers instructions Residential and Mobile Home Installations These are the minimum pieces required Other parts may be required for your particular installation Minimum Components for Hori...

Страница 14: ...tion Venting terminals may not be recessed into a wall or siding 1 Set the unit in the desired location Check whether or not wall studs are in the way when the venting system is attached If wall studs are in the way you may want to adjust the location of the unit 2 Assemble the desired combination of pipe and elbow to the appliance adaptor with pipe seams facing down Offsetting the pipe seams as d...

Страница 15: ...wing page and note which restrictor setting is recommended The flue restrictor is shipped in the firebox of your stove To install the restrictor see Figure 18 Remove the two 5 32 allen head screws A below Using pliers repeatedly bend the unwanted portion of the flue restrictor and discard Install the flue restrictor using the two 5 32 allen head screws according to the diagram below Install the fl...

Страница 16: ...SS 35 LP 0 3 horizontal 14 Snorkel Required No Light Obstructor VISN 35 SDVSS 35 NG 0 3 horizontal 14 Snorkel Required No Light Obstructor Offsets must remain within maximum and minimum lines To install the stove with pipe directly out the back a snorkel is not required for VISN 25 SDVSS 25 gas stoves A snorkel is required for the VISN 35 SDVSS 35 gas stoves See Pages 14 and 15 for snorkel install...

Страница 17: ...ded above meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly I Clearance to service regulator vent outlet 3 feet 91 cm 3 feet 91 cm J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 6 in 15 2 cm for appliances 10 000...

Страница 18: ...ght of the inlet tap To check manifold pressure with the appliance burning at the high burn setting insert a small flat bladed screwdriver into the tap and turn a half turn counterclockwise Cover the tap with the line from the manometer and check the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution retighten if n...

Страница 19: ...ôle le fonctionnement du foyer en le faisant basculerdeMarcheàArrêt etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour éliminer la poussière et les traces de graisse ou d huile Collez l étiquette sur la surface de la plaque de l interrupteur mural qui contrôle le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principaleme...

Страница 20: ...ice technician Force or attempted repair may result in a fire or explosion D DO NOT use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety information on this page before proceeding 2 If appli...

Страница 21: ...cause the flames to turn orange sooner may result in poor combustion sooting and a hazardous situation See the drawing to the right showing proper flame appearance When testing for proper operation If an optional thermostat is installed adjust it to its highest temperature setting Visually determine that main burner gas is burning properly i e no floating lifting or flashback Adjust the primary ai...

Страница 22: ...e sound of rush ing air may be heard The blower sounds may be reduced by adjusting the speed control located on the blower assembly Also a slight clicking soundmaybeheardasthegasvalveorblowerswitchisturnedonandoff Paint Curing This stove has been painted with Stove Bright high temperature metallic paint It leaves the factory dry to the touch but completes the curing process as the stove is used To...

Страница 23: ...sing the thermostat or remote control and set the thermostat or remote control to the lowest temperature when you wish to use the rocker switch only otherwise one may override the other Millivolt Control System This stove operates on a millivolt control system As such no additional power supply is needed for the stove to heat The pilot assembly contains a thermocouple that when heated by the pilot...

Страница 24: ...mopile and thermocouple and extend across the main burner tube ports Be careful not to back the screw out of its threads o Check that the area around the stove is kept clear and is free of combustible materials gasoline and other flammable vapors and liquids o Check the millivolt system as per the table on this page Millivolt and System Checks Check Test To Test Connect Meter Leads to Terminals Th...

Страница 25: ...eaner with ammonia on the door and glass gasket as it may dis solve the gasket glue Repair If the glass is broken in the glass door the entire door metal frame gasket and glass should be replaced as a unit This replacement glass door is available from your Lennox Hearth Products dealer Do not use substitute parts or materials The glass is neo ceramic and alterna tive types must not be used NOTE BE...

Страница 26: ...rocess 2 Remove the log set see Log Installation 3 Remove the two phillips head screws from the back of the burner 4 Lift the right end of the burner and slide if off the orifice and shutter tube Remove the burner from the firebox 5 Remove the labeled cover through which the valve control knobs protrude by removing the two screws securing it and slide it off the valve knobs 6 Mark and disconnect w...

Страница 27: ...in pilot position for 1 2 minutes and light Check for spark at electrode and pilot if no spark and electrode wire is properly connected replace igniter See Lighting Instructions Pilot will not stay lit after carefully following lighting instructions Pilot flame is not sur rounding thermocouple Thermocouple not generating sufficient voltage Air in gas supply line Check pilot flame adjustment see Ma...

Страница 28: ... l entretien des commandes étiquetez tous les fils avant de les débrancher Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux POWER CORD SNAP SWITCH GRN 6 SPEED CONTROL SWITCH BLOWER BLK 6 RED 12 RED 7 RED 8 BLK 16 8 MALE SPADE 1 4 FEMALE SPADE 1 4 RING LUG CRIMP FEMALE SPADE 1 4 STRIP OUTER JACKET 6 W H T 6 2 PL FEMALE SPADE 1 4 FEMALE SPADE 1 4 MALE SPADE 1 4 FEMAL...

Страница 29: ...so requires 75265 conversion kit H6034 Burner Assembly H5922 Pilot Assembly NG or LP H5942 Gas Control Valve NG if LP also requires H5945 LP Regulator H5943 Regulator NG H5945 Regulator LP H5966 Orifice Main Burner 42 NG 25 000 BTU H5967 Orifice Main Burner 34 NG 35 000 BTU H5964 Orifice Main Burner LP 53 25 000 BTU H5970 Orifice Main Burner LP 50 35 000 BTU H3071 Blower H5875 Blower Snap Switch H...

Страница 30: ...ch Up Paint Kit H8159 TSPK B Touch Up Paint Metallic Black 12 oz aerosol Controls H4635 DWTK Wall Thermostat Digital H0251 RCL STAT Remote Control Deluxe Thermostat DC ref form 750129M 70005 RT AC Remote Control Thermostat AC ref form 775280M Wall Thermostat Remote Control Product Reference Information Cat No Description Ship Weight Ship Volume 55107C VISN 25 35 Direct Vent Freestanding Gas Stove ...

Страница 31: ...0 23 500 25 000 17 500 25 000 18 000 MANIFOLD PRESSURE IN WC 3 5 10 0 3 5 10 0 MIN INLET PRESSURE IN WC 5 0 11 5 0 11 ORIFICE DMS 0 2 000 FT 0 610 M 34 111 IN 50 070 IN 42 093 IN 53 059 IN UNIT FACTORY EQUIPPED FOR 0 2000 FT 0 610 M IN CANADA 0 4500 FT 0 1370 M ELECTRICAL RATING 120 VAC 60 HZ LESS THAN 2 AMPS DATE OF MANUFACTURE DATE DE FABRICATION 2008 2010 2011 2009 JANV JAN FEVR FEB MARS MAR AV...

Страница 32: ...urnisseur de gaz Si vous opérez cet appareil sans qu il ne soit correctement raccordé à un conduit d évacuation vous pourriez risquer d être empoisonné au monoxyde de carbone CO ce qui pourrait entraîner des conséquences grave ou la mort POUR COUPER L ALIMENTATION EN GAZ DE L APPAREIL 1 Pour arrêter le brûleur mettre l interrupteur à la position OFF ou ajustez le thermostat à une température en de...

Страница 33: ...33 NOTES ...

Страница 34: ...s for future refer ence Product reference information We recommend that you record the following important information aboutyourappliance PleasecontactyourLennoxHearthProductsdealer for any questions or concerns For the number of your nearest Lennox Hearth Products dealer please call 1 800 9 LENNOX Replacement parts See Page 29 for a complete replacement parts list Use only parts sup plied from th...