12
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Step 14. HOOD INSTALLATION
All of these appliances must have a hood
installed prior to operating on the side with
a glass enclosure panel.
On all clean face units, slide the hood into
the slot on the lower edge of the radiant panel
(see Figure 30).
On louvered face units, slide the hood into
the slots on the lower edge of the cabinet top
(
see Figure 31).
Figure 27
Step 13. SPILLAGE TEST
After appliance installation, perform this spill-
age test to verify that proper venting condi-
tions exist:
1 - Place unit in its normally-operated con-
dition, that is, with the glass enclosure panel
in place.
2 - Close all doors and windows in the
room. Turn on all exhaust fans in the house.
3 - Light the appliance.
4 - Wait 15 minutes.
5 - To check for venting action, start by
holding a smoke producing device within an
inch of one edge (side edge, not top or
bottom edge) of one glass enclosure panel.
The smoke should be drawn toward the edge
of the glass enclosure panel. Continue the
test by moving the smoke producing device
along the entire length of both side-edges of
the glass door.
6 - If the smoke is not drawn towards the
edges of the glass door turn off the appli-
ance and call a qualified service technican.
Manually-Reset Safety Limit Switch
This appliance is equipped with a manually-
reset blocked flue safety limit switch. Refer to
Figure 28 for its location. If, during appliance
operation, the flame goes out (independently
of the burner on/off wall switch), it may be
due to the operation of this safety limit switch.
First allow the appliance to cool. Remove
top louver panel. Then reset the safety limit
switch by pushing the red reset button, lo-
cated between the wire terminals, on the back
of the switch. See
Detail A of Figure 28 for
location.
The appliance should then relight and remain
lit. Reinstall top louver panel. If the appliance
does not relight, turn off the appliance and
call for a qualified service technician.
To replace the blocked flue safety limit switch
refer to
Figure 28 (Details B and C):
NOTE - This procedure should only be per-
formed by a qualified service technician.
Important - Turn electrical power off before
beginning this procedure.
1 - Lower the bottom control compartment
access panel. Remove the glass enclo-
sure panel: open the latch (located in
the center of the unit front opening,
under the firebox floor) securing the
glass enclosure panel. Remove the
panel by tilting it outward at the bottom
and lifting it up. Set the door aside
protecting it from inadvertent damage.
See Figure 26 on page 11.
2 - Remove the lintel securing screws (3)
and then remove the lintel. One of the
lintel cabinet top holes is shown in
Figure 28 (Detail B).
3 - Remove the scoop securing screws
(3) and then remove the scoop. See
Figure 28 (Detail B).
4 - Remove the safety switch bracket secur-
ing screws (2), and pull the switch/bracket
assembly, with low voltage wires at-
tached, through the side panel slot into
the firebox. See
Figure 28 (Detail C).
5 - Replace the switch.
6 - Reinstall the switch/bracket assembly.
7 - Reinstall the scoop and lintel.
8 - Reinstall the glass enclosure panel.
9 - Raise the bottom control compartment
access panel.
10 - The appliance should then relight and
remain lit. If this does not occur, check
unit for a blocked flue condition.
Figure 28
Blocked Flue Safety Limit Location
Inside View of Firebox -
Top/Right Side Intersection
Air Shutter
Venturi
Set Screw - Factory Located in the
Natural Gas Position; Relocate Set
Screw for LP/Propane Gas in the
Alternate Position. See Table below
for Air Shutter Openings for these
Set Screw Locations.
s
l
e
d
o
M
s
a
G
e
p
y
T
R
I
A
Y
R
O
T
C
A
F
G
N
I
T
T
E
S
R
E
T
T
U
H
S
)
m
m
(
s
e
h
c
n
i
0
0
5
-
B
.
t
a
N
n
e
p
o
)
9
5
.
1
(
6
1
/
1
.
p
o
r
P
4
/
1
n
e
p
o
)
5
3
.
6
(
0
0
6
-
B
.
t
a
N
n
e
p
o
)
9
5
.
1
(
6
1
/
1
.
p
o
r
P
6
1
/
5
n
e
p
o
)
4
9
.
7
(
0
0
8
-
B
.
t
a
N
d
e
s
o
l
c
y
ll
u
F
.
p
o
r
P
2
3
/
7
n
e
p
o
)
5
5
.
5
(
Detail A
Wire
Termianls
Back Of
Limit
Switch
Cabinet
Corner
Door
Frame
Fire Box Top
Limit
Limit/Bracket
Securing Screws
Lintel Securing-Screw
Hole in Cabinet Top
View Without Scoop
Scoop
Scoop Securing Screws
Fire Box Top
Lintel Securing Screw
Hole in Cabinet Top
Detail C
Detail B
f i r e - p a r t s . c o m