Step 14. HOOD INSTALLATION

All of these appliances must have a hood
installed prior to operating on the side with
a glass enclosure panel.

On all clean face units, slide the hood into
the slot on the lower edge of the radiant panel
(see Figure  30).

On louvered face units, slide the hood into
the slots on the lower edge of the cabinet top
(

see Figure 31).

Figure 27

Step 13. SPILLAGE TEST

After appliance installation, perform this spill-
age test to verify that proper venting condi-
tions exist:

1 - Place unit in its normally-operated con-
dition, that is, with the glass enclosure panel
in place.
- Close all doors and windows in the
room. Turn on all exhaust fans in the house.
3 - Light the appliance.
4 - Wait 15 minutes.
5 - To check for venting action, start by
holding a smoke producing device within an
inch of one edge (side edge, not top or
bottom edge) of one glass enclosure panel.
The smoke should be drawn toward the edge
of the glass enclosure panel. Continue the
test by moving the smoke producing device
along the entire length of both side-edges of
the glass door.
6 - If the smoke is not drawn towards the
edges of the glass door turn off the appli-
ance and call a qualified service technican.

Manually-Reset Safety Limit Switch

This appliance is equipped with a manually-
reset blocked flue safety limit switch. Refer to
Figure 28  for its location. If, during appliance
operation, the flame goes out (independently
of the burner on/off wall switch), it may be
due to the operation of this safety limit switch.
First allow the appliance to cool.  Remove
top louver panel.  Then reset the safety limit
switch by pushing the red reset button, lo-
cated between the wire terminals,  on the back
of the switch.  See 

Detail A of Figure 28 for

location.

The appliance should then relight and remain
lit.  Reinstall top louver panel.  If the appliance
does not relight, turn off the appliance and
call for a qualified service technician
.

To replace the blocked flue safety limit switch
refer to

 Figure 28 (Details B and C):

NOTE - This procedure should only be per-
formed by a qualified service technician.

Important - Turn electrical power off before
beginning this procedure.

- Lower the bottom control compartment

access panel.  Remove the glass enclo-
sure panel: open the latch (located in
the center of the unit front opening,
under the firebox floor) securing the
glass enclosure panel. Remove the
panel by tilting it outward at the bottom
and lifting it up. Set the door aside
protecting it from inadvertent damage.
See Figure 26 on page 11.

2 - Remove the lintel securing screws (3)

and then remove the lintel. One of the
lintel cabinet top holes is shown in
Figure 28 (Detail B).

3 - Remove the scoop securing screws

(3) and then remove the scoop. See
Figure 28 (Detail B).

4 - Remove the safety switch bracket secur-

ing screws (2), and pull the switch/bracket
assembly, with low voltage wires at-
tached, through the side panel slot into
the firebox.  See 

Figure 28 (Detail C).

5 - Replace the switch.
6 - Reinstall the switch/bracket assembly.
- Reinstall the scoop and lintel.
- Reinstall the glass enclosure panel.
- Raise the bottom control compartment

access panel.

10 - The appliance should then relight and

remain lit. If this does not occur, check
unit for a blocked flue condition.

Figure 28

Blocked Flue Safety Limit Location

Inside View of Firebox -

Top/Right Side Intersection

Air Shutter

Venturi

Set Screw - Factory Located in the
Natural Gas Position; Relocate Set
Screw for LP/Propane Gas in the
Alternate Position. See Table below
for Air Shutter Openings for these
Set Screw Locations.

s

l

e

d

o

M

s

a

G

e

p

y

T

R

I

A

Y

R

O

T

C

A

F

G

N

I

T

T

E

S

R

E

T

T

U

H

S

)

m

m

(

s

e

h

c

n

i

0

0

5

-

B

.

t

a

N

n

e

p

o

)

9

5

.

1

(

6

1

/

1

.

p

o

r

P

4

/

1

n

e

p

o

)

5

3

.

6

(

0

0

6

-

B

.

t

a

N

n

e

p

o

)

9

5

.

1

(

6

1

/

1

.

p

o

r

P

6

1

/

5

n

e

p

o

)

4

9

.

7

(

0

0

8

-

B

.

t

a

N

d

e

s

o

l

c

y

ll

u

F

.

p

o

r

P

2

3

/

7

n

e

p

o

)

5

5

.

5

(

Detail A

Wire
Termianls

Back Of
Limit
Switch

Cabinet
Corner

Door
Frame

Fire Box Top

Limit

Limit/Bracket

Securing Screws

Lintel Securing-Screw

 Hole in Cabinet Top

View Without Scoop

Scoop

Scoop Securing Screws

Fire Box Top

Lintel Securing Screw
Hole in Cabinet Top

Detail C

Detail B

f i r e - p a r t s . c o m

Содержание SUPERIOR B-VENT 500 Series

Страница 1: ...vous trouvez Evacuez la piéce le bâtiment ou la zone Appeflez immédiatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service dos incendies L installationetservicedoitêtreexécutéparunqualifié installer agence de service ou le fournisseur de gaz AVERTISSEMENT ASSUREZ VOUS DE BIEN SUIVRE LESINSTRUCTIO...

Страница 2: ...er s manual installation instructions log set supplement and warranty envelope is lo cated in the control area Figure 1 INTRODUCTION Themillivoltappliancesaredesignedtooperate on either natural or propane gas A millivolt gas control valve with piezo ignition system pro vides safe efficient operation Theelectronicappliancesaredesignedtooper ate on either natural or propane gas An elec tronic interm...

Страница 3: ...djacent to the outlet to the main burner Minimum inlet gas pressure to the appliance is 5 0 inches water column 1 24 kPa for natural gas and 11 inches water column 2 74 kPa for propane for the purpose of input adjustment Maximum inlet gas supply pressure to the appliance is 10 5 inches water column 2 61kPa for natural gas and 13 0 inches water column 3 23 kPa for propane The appliance must be isol...

Страница 4: ...s may not be installed in bedrooms in Canada WARNING CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZ ARDS OF HIGH SURFACE TEMPERA TURES USE CAUTION AROUND THE APPLIANCE TO AVOID BURNS OR CLOTHING IGNITION YOUNG CHIL DREN SHOULD BE CAREFULLY SUPER VISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE WARNING DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIALS ON OR NEAR THIS APPLIANCE These applian...

Страница 5: ...OUT 16 406 13 3 76 1 35 140 5 9 238 2 53 Right Side View 140 5 9 238 1 35 Left Side View GAS INLET See Also Right Side View ELECTRICAL INLET See Also Right Side View 3 76 OUTSIDE AIR SHUTTER 8 227 7 187 ELECTRICAL INLET Optional Venting Gas Vent Rule Gas vent caps are not permit ted within 8 feet 2 4 mm of a vertical wall or similar obstruction Gas vent caps that are located 8 or more from a porti...

Страница 6: ...led Figure 8 TYPICAL INSTALLATION SEQUENCE The typical sequence of installation follows however each installation is unique resulting in variations to those described See the page numbers references in the follow ing steps for detailed procedures Step 1 page 7 Construct the appliance framing Step 2 page 7 Route gas supply line to appliance location Step 3 page 7 Position the appliance within the f...

Страница 7: ...d to the rear wall then the 16 in 406 mm must be measured from the drywall surface It is important that this dimension be exact If the appliance is to be elevated above floor level a solid continuous platform must be constructed The header may rest on the top metal spacers but must not be notched to fit around them Consult all local codes Step 2 Route Gas Supply Line Route gas line see Figure 10 u...

Страница 8: ...ting of several units is contemplated it should be discussed with an architect and the local Building Department Do not place insulation materials within 1 in of the gas vent system Step 5 FIELD WIRING Refer to Section A for millivolt appliances and Section B for electronic appliances The gas valve is set in place and pre wired at the factory on both models A SIT and Honeywell Millivolt Wiring See...

Страница 9: ...igure 18 Secure all joints tightly using appropri ate tools and sealing compounds en sure propane resistant compounds are used in propane applications Make gas line connections All codes require a shut off valve mounted in the supply line Figure 19 illustrates two methods for con necting the gas supply The flex line method is acceptable in the U S however Canadian re quirementsvarydependingonlocal...

Страница 10: ...wlspace not considered part of the living area of the home Note Do not terminate outside air kit in attic space under any circumstances CAUTION NEVER LOCATE INLET WHERE IT CAN BE BLOCKED BY SHRUBS SNOW DRIFTS ETC NEVER LOCATE INLET IN GA RAGE OR ANY AREA WHERE THERE IS AN OTHERFUELBURNINGAPPLIANCEORPROD UCTSEMITTINGCOMBUSTIBLEGASESSUCH AS PAINT GASOLINE ETC IN COLD CLI MATES IT IS RECOMMENDED THE ...

Страница 11: ...r frame draws shut Fasten the latch located underneath the fire box floor to the door s vee flange Close the latch securely WARNING HANDLE THIS GLASS WITH EXTREME CARE THE GLASS PANEL IS SUSCEPTIBLE TO DAMAGE DO NOT SCRATCHWHILEHANDLINGORWHILE RE INSTALLING THE GLASS DOOR FRAME Thepackagedlogsarelocatedwithinthefirebox The decorative volcanic stone and glowing em bers are packaged separately in pl...

Страница 12: ...afetylimitswitch refer to Figure 28 Details B and C NOTE This procedure should only be per formed by a qualified service technician Important Turn electrical power off before beginning this procedure 1 Lower the bottom control compartment access panel Remove the glass enclo sure panel open the latch located in the center of the unit front opening under the firebox floor securing the glass enclosur...

Страница 13: ... non combustible materials may be installed at any height above the appliance opening however do not allow anything to hang below the hood COLD CLIMATE INSULATION Ifyouliveinacoldclimate sealallcracksaround your appliance with noncombustible material and wherever cold air could enter the room It is especially important to insulate outside chase cavity between studs and under floor on which applian...

Страница 14: ... OF LIFE THE INSTALLATION IS NOT PROPER AND COM PLETEUNTILTHEOPERATIONOFTHECONVERTED APPLIANCE IS CHECKED AS SPECIFIED IN THE OWNERINSTRUCTIONSSUPPLIEDWITHTHEKIT THE QUALIFIED SERVICE AGENCY PERFORMING THIS INSTALLATION ASSUMES RESPONSIBILITY FOR THIS CONVERSION AVERTISSEMENT CET ÉQUIPEMENT DE CONVERSION SERAINSTALLÉPARUNEAGENCEQUALIFIÉEDESERVICE CONFORMÉMENTAUXINSTRUCTIONSDUFABRICANTET TOUTES EXI...

Страница 15: ... a 7 16 open end wrench and turn the pilot hex fitting counter clockwise 1 4 turn See Figure 35 Figure 34 Pilot for Honeywell Millivolt Gas Valve Loosening of Hex Fitting For Orifice Strip Tab Positioning Pilot for Honeywell Millivolt Gas Valve Figure 37 Note The orifice strip tab may be randomly located on any side of the hex fitting d Push the orifice strip tab all the way against the hex fittin...

Страница 16: ...ith the one provided with the kit See the following table for orifice sizes for natural and propane models Figure 40 illustrated the orifice Figure 38 Step 6 Electronic Appliances Honeywell Systems SeeFigure38andtheinstructionsprovidedwith the kit Remove the slotted cap screw o ring pressure regulatingadjustingscrewandspring Retainallpartsforpossiblelateruse Installnew components from the kit Blac...

Отзывы: