background image

Report No.116-L-49-5

INSTALLATION AND OPERATION INSTRUCTIONS

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
•  DO NOT light any appliance.

•  DO NOT touch any electrical switches.

•  Do not use any phone in your building.

•  Immediately call your gas supplier from a neighbor’s phone. Follow your gas supplier's instructions.

•  If your gas supplier cannot be reached, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier

.

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property 

damage, personal injury or loss of life.

Vent-Free Millivolt

Dual-Listed Gas Log Sets

Installer: Leave This Manual With The Appliance.

Consumer: Retain This Manual For Future Reference.

Shadowdance™ Series

P/N 850,051M  Rev. A, 08/2007

I

n the Commonwealth of Massachusetts:

  • Installation must be performed by a licensed plumber or gas fitter

    • See Table of Contents for location of additional 

       Commonwealth of Massachusetts requirements

Gas Train Models:

LSVFSD-NG

LSVFSD-LP

Log Sets Sold Separately

Log Set Models:

LSVFSD-18 Logs

LSVFSD-24 Logs

     

WARNINGS

 

Hot! Do not touch!  This appliance will be hot during operation and will retain heat for a while after 

shutting off the appliance.   Severe burns may result. 

• 

 

Carefully supervise children in the same room as appliance.

 

Improper installation, adjustment, alteration, service or maintenance can cause injury or property 

damage. Refer to this manual. For assistance or additional information consult a qualified installer, 

service agency or the gas supplier. 

 

Do not build a wood fire. Do not burn wood or other material in these appliances.

 

Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fire-

place size requirement.  Do not install the appliance in the fireplace, unless the fireplace meets the minimum 

dimensions required for the installations (see 

Page 3)

.

 

This is an unvented gas log appliance.  It uses air (oxygen) from the room in which it is installed. Provisions for adequate 

combustion and ventilation air must be provided.  Refer to Combustion and Ventilation Air Section on 

Page 5

.

 

Important: Read and understand these instructions completely before installing your unvented room heaters.

 

This appliance is only for use with the type of gas indicated on the rating plate.  This appliance is not convertible 

for use with other gases. If the gas supply differs, DO NOT INSTALL the appliance. Contact your dealer to obtain 

the correct appliance.

 

This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where 

not prohibited by local codes.

 

Lennox™ vent-free gas logs are designed for use as a supplemental heater.   They are not intended for continuous use 

as a primary heat source.

TM

DR

AF

T

8-2

4-2

00

7

US

Содержание Shadowdance LSVFSD-18

Страница 1: ...fter shutting off the appliance Severe burns may result Carefully supervise children in the same room as appliance Improper installation adjustment alteration service or maintenance can cause injury o...

Страница 2: ...NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs WARNINGS Allow the appliance to cool befo...

Страница 3: ...We extend our continued support to help you achieve the maximum benefit and enjoy ment available from your new gas log heater It is our goal at Lennox Hearth Products to provide you our valued custom...

Страница 4: ...op must be installed to prevent full closure of the fireplace damper and provide a minimum 29 square inch flue opening at all times This appliance is for installation in a solid fuel burning fireplace...

Страница 5: ...th 248 CMR 3 05 the following requirements must be satisfied 1 A permit shall be obtained from the head of the fire department and the local or state gas inspector having jurisdiction for the installa...

Страница 6: ...ible side wall Figure 2 4 Compare the maximum BTU Hr the space can support with the actual amount of BTU Hr used __________ BTU Hr max the space can support __________ BTU Hr actual amount of BTU Hr u...

Страница 7: ...mantel profile is unsafe you may either Raise the mantel to an acceptable height or Remove the mantel Example Thebottomofthemantelmayprojectfromthewallamaximum of 2 1 2 at a minimum of 28 above the o...

Страница 8: ...fvalveandunionmustbeinstalledupstream of the appliance within the fireplace cavity when rigid pipe is used Important Hold appliance regulator with a wrench to prevent movement when connecting to inlet...

Страница 9: ...n the gas control knob off pilot on to the OFF position Either tighten or refasten the leaking connection then retest as described above C When the gas lines are tested and leak free be sure to rinse...

Страница 10: ...pin and the rear ember bed locating pin as shown in Figure 13 Middle Log Locating Pins 4 Place left and right front logs onto front grate locating pins as shown in Figure 14 Figure 12 Install Rear Lo...

Страница 11: ...er Top Log Locating Pins Right Top Log Locating Pins 8 Place Left Top Twig 24 model only onto corresponding notch on rear log as shown in Figure 18A The front of the Left Top Twig should be up against...

Страница 12: ...couple to cool When the thermocouple cools the log set will shut off If pilot flame pattern is incorrect or if log set shuts off contact your service technician Propane Pilot Shown Propane Pilot Shown...

Страница 13: ...the control knob occasionally Do not use cleaning fluids to clean the logs or any other part of the appliance Remove the log set gently handling at each end Use a vacuum cleaner to remove loose partic...

Страница 14: ...xe Remote Control System Model RC STAT TheModelRCL T Deluxe RemoteControlSystem has all of the features of the standard system along with an added easy to read LCD screen which presents access to many...

Страница 15: ...LSVFSD LP only 18 Gas Log Set 24 Gas Log Set Charred Ember Kit Cat No Model No Description H6894 LSVFSD CEK Charred Ember Kit Charred Ember Kit An optional 2 piece Charred Ember Kit is available to en...

Страница 16: ...e Setting Gas Inlet Pressure Valve Operation Orifice Size Top Orifice Size Bottom Air Shutter Opening LSVFSD NG 37 000 24 500 Natural Piezo 1 6 3 5 W C Max 10 5 W C Min 5 0 W C Millivolt 094 071 1 8 L...

Страница 17: ...ht any appliance Do not touch any electrical switches TO TURN OFF GAS TO APPLIANCE 1 Turn remote wall switch OFF The pilot will remain lit for normal service 2 For complete shutdown turn remote wall s...

Страница 18: ...tting is not correct Replace gas regulator 6 ODS pilot lights but flame goes out when control knob is released A Control knob not fully pressed in Press in control knob fully B Control knob not presse...

Страница 19: ...p Burner H3913 6 Piezo Igniter 10K86 7 ODS Pilot Assembly Millivolt Natural H4113 8 ODS Pilot Assembly Millivolt Propane L P G H4170 9 Knob Extension Pilot On Off 60J74 10 Knob Extension Hi Lo 60J95 1...

Страница 20: ...hout notice in design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2007 by Lennox Hearth P...

Отзывы: