background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

16

REPLACEMENT PARTS

ITEM

NO.

DESCRIPTION

MPE-36R

CAT. NO.

QTY

1

Bulb Kit, (10 Each 35w Halogen)

H1623

1

2

Side Frames, 1 Left And 1 Right

H1624

1

3

Circuit Board

H1625

1

4

Nailing Flange Kit, (4 Each)

H1626

1

5

Glass Brick Panel 

H1627

1

6

Glass Retaining Bracket Kit: Left, Right, & Top 

H1628

1

7

Grate Assembly 

H1629

1

8a

Blower, Heating Element & Access Panel Assembly

H1630

1

8b

Fuse Plate Assembly (5 each)

H5043

1

9

Flame Cylinder Assembly

H1631

1

10

Flame Motor

H1632

1

11

Lennox Logo Kit (1 Each)

12L15

1

12

Log / Ember Bed Assembly

H1634

1

13

Panel, Bottom, Front

H1635

1

14

Panel, Flame Cover

H1636

1

15

Panel, Louver, Upper Front

H1637

1

16

Panel, Upper Frame Top

H1638

1

17

Electrical Outlet Cover Plate

H1639

1

18

Screen Set, Pull

H1640

1

19

Switch, Toggle (1 Each)

H1641

1

20

Transformer Assembly

H1642

1

21

Wire Harness

H1643

1

22

Remote Control, Electric

H1644

1

23

Power Cord (110 V only)

H1645

1

Note: If touch-up paint is needed, use Rust-oleum

®

, Painter’s Touch, Flat Black (part number 1976) available at most stores which sell 

aerosol touch-up paint.

Содержание MPE-36R

Страница 1: ...n an unsafe and potentially dangerous installation IMPORTANT IFOPTIONALGLASSDOORSAREPURCHASED TO ASSURE PROPER ALIGNMENT INSTALL THIS FIREPLACE IN A SQUAREANDPLUMBCONDITION USINGSHIMSASNECESSARY AT SI...

Страница 2: ...alids and whenever the heater is left oper ating and unattended DO NOT USE THIS APPLIANCE OUT DOORS DO NOT EXPOSE FIREPLACE TO THE ELEMENTS SUCH AS RAIN ETC THIS APPLIANCE IS NOT INTENDED FOR USE IN B...

Страница 3: ...le 1 240 Volt 60 Hz 3000 Watt ref Page 11 Use three conductor non metallic sheath cable with ground wire total four wires for the incoming power supply The wire used must conform to local and national...

Страница 4: ...ss 13 3 4 350 mm 5 1 4 134 mm 24 1 2 622 mm 27 1 2 700 mm 21 1 8 537 mm Electrical Access Cover Power Cord FIREPLACE SPECIFICATIONS Front View Side View 37 1 2 945 mm 26 1 2 38 5 8 668 mm 981 mm 52 3...

Страница 5: ...applicable regulations to reduce the risk of fire electrical shock and injury to individuals IMPORTANT Any electrical re wiring of this appliance must be done by a qualified electrician WARNING Do not...

Страница 6: ...nd down covering the outlet or glass enclosure panel optional kit There are a wide variety of finished looks for these fireplaces from formal wall decor with elaborate mantels to rustic wood paneling...

Страница 7: ...t then press the display button C to activate the lights Note If the flame does not come on imme diately adjust brightness and intensity buttons E K 4 Toincreasethebrightness pressandrelease the light...

Страница 8: ...eaners on the glass panel Do not spray liquids directly onto any surface of the fireplace 3 Open the screens remove glass panel enclosure if applicable 4 OPTIONAL To ensure that the brick panel isn t...

Страница 9: ...s provided in kit 4 Remove the 2 screws on the front of the grate see Figure 12 Also see item 7 on Page 17 Remove Grate 5 Lift out log ember assembly by tilting for ward and firmly pulling on back of...

Страница 10: ...n Page 3 N L1 GROUND YELLOW AND GREEN ORANGE BLACK BLUE BLUE WHITE N L1 N1 N2 L2 120 V 1600 W 120 V AC GROUND G IF THE APPLIANCE IS TO BE HARD WIRED IN THE POWER CORD MUST BE REMOVED SEE INSTRUCTION 2...

Страница 11: ...perature Sensor Remote Sensor PTC Heater 1 L Heater 2 L Fan Motor L Flame Motor L Light L L R1 L R2 L FAN L M P L L LIGHT L1 L2 N1 N2 N MAIN POWER L1 L2 N N FLAME L FLAME SIP4 K P SIP2 REMOTE SIP3 K H...

Страница 12: ...MS optional kits see Page 18 When using the manual control panel power on off switch the outside power on off switch optional wall switch kit must be in the OFF position When using the outside power o...

Страница 13: ...the following information 1 Turn off circuit breaker 2 Remove cover plate located on the left side of appliance 3 Locate the the black and white wires and pull out the length needed to reach wall ther...

Страница 14: ...witch per instructions provided with kit and per the following information 1 Turn off circuit breaker 2 Remove cover plate located on the left side of appliance 3 Locate the 2 red wires and pull out t...

Страница 15: ...ce the flame motor 3 Dimorpoorlyvisibleflameorlog set and ember is not glowing Light bulb s burnt out or wiring is loose Homeowner Inspect all wiring for loose connec tions and repair or replace if ne...

Страница 16: ...5043 1 9 Flame Cylinder Assembly H1631 1 10 Flame Motor H1632 1 11 Lennox Logo Kit 1 Each 12L15 1 12 Log Ember Bed Assembly H1634 1 13 Panel Bottom Front H1635 1 14 Panel Flame Cover H1636 1 15 Panel...

Страница 17: ...CALE 17 REPLACEMENT PARTS COMPONENT DIAGRAMS MPE 36R 8b 23 14 16 11 1 4 2 5 6 6 7 8a 12 13 15 19 17 Front View POWER ON OFF DISPLAY ON OFF Dimmer Brighter EMBERS HEATER ON OFF TEMP CONTROL HIGH MED LO...

Страница 18: ...control for optimum comfort Cat No Model Description 89L36 WTK Wall Thermostat Kit Wall Switch Kit Trim Kit Glass Enclosure Kit A 41 1041 mm B 31 7 8 810 mm C 34 3 8 872 mm D 36 914 mm E 2 1 2 64 mm...

Страница 19: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 19 NOTES...

Страница 20: ...The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distribut...

Отзывы: