background image

10

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

42-1/2”

(1080 mm)

17-1/8”

(435 mm)

28-5/16”

(719 mm)

42”

(1067 mm)

43”

(1092 mm)

43”

(1092 mm)

27-1/2”

(699 mm)

10-5/8”

(270 mm)

36”

(914 mm)

33”

(838mm)

21-1/4

(540 mm)

Knock-Out

for Ducting

Knock-Out

for Ducting

Outside Air

Intake

FRAMING DIMENSIONS

Fireplace Opening Width

A

42-1/2"

1080 mm

B

43-1/4"

1099 mm

C

33"

838 mm

D

16-1/2"

419 mm

E

85"

2159 mm

F

42-1/2"

1080 mm

G

27"

686 mm

H

26"

660 mm

J

60-1/8"

1527 mm

K

8"

203 mm

L

1"

25 mm

F

J

21-1/2”

(546mm)

E

D

 

 

OUTSIDE CHASE

G

H

C

L

*

Back Wall of Chase/Enclosure

Including Finising Materials if any

 

 

Rough Framing Face (Unfinished Shown)

* Zero Clearance From Back Spacer to Wall 

Corner Installation

Figure 10  - Framing Dimensions

Notes

Due to Lennox Hearth Products ongoing 

commitment to quality, all specifications, 

ratings  and  dimensions  are  subject  to 

change without notice.
All  framing  dimensions  calculated  for 

1/2"  dry  wall  at  the  fireplace  face.    If 

sheathing  the  chase  or  finishing  with 

other thickness materials, calculations 

will  need to be made.
* The fireplace must not be in contact with 

any insulation or loose filling material. 

Cover the insulation with Drywall panels 

around the fireplace.
Combustible  materials  can  NOT  be 

used  in  the  space  directly  above  the 

fireplace.  Do not fill the space above 

the fireplace with any material (Except 

the wood framing)

7' MIN.

2" X 3"

MIN.

A

G

B

Rough Framing Face 

(unfinished shown)

(593mm)

23-11/32”

K

Combustion

Air Kit

Combustible materials can NOT be 

used in the space directly above the 

fireplace.  Do not fill the space above 

the fireplace with any material (Except 

the wood framing)

1/2” Plywood

Содержание ELITE ME43BK SP

Страница 1: ...h Products wood burning fireplaces are designed for use as a supplemental heater They are not intended for continuous use as a primary heat source INSTALLATION AND OPERATION INSTRUCTIONS WARNINGS Hot...

Страница 2: ...ive pillows at least 48 1219 mm from the front fireplace opening WARNING Neverleavechildrenunattended when there is a fire burning in the fireplace WARNING Never leave your fireplace unat tended while...

Страница 3: ...he retractable doors and firescreens Page 5 How to use the outside air kit Page 5 Fireplace Installation Pre installation Page 5 Tools and building supplies Page 6 Precautions Page 6 Installation proc...

Страница 4: ...spected by a qualified chimney sweep or a fire department inspector Door Frame Care Use a glass cleaner and a soft cloth to polish the frame Do not use abrasives such as steel wool or steel pads for t...

Страница 5: ...fully and light the newspaper Once the kindling fire is well established cordwood can be added The unit will burn best with a minimum of two piecesofcordwoodspaced1 to2 apartandal lowingairtogetunder...

Страница 6: ...ve Building supplies 2 x 3 or heavier lumber Drywall panel or equivalent Silicone caulking non combustible Overlay material for fireplace fa ade Hearth extension non combustible precautions The most i...

Страница 7: ...than the rest of the building below the attic CEILING FLOOR SEPARATION MUST HAVE THE SAME INSULATION LOCAL CODE REGULATION FOR CEILING MUST BE APPLIED TO THE CEILING FLOOR SEPARATION I E FIRESTOP ETC...

Страница 8: ...r Cold Climate Installations Climates where temperatures will fall below 32 F 0 C The heating performance of the appliance will vary depending upon the level of insulation house design how the applian...

Страница 9: ...ster at floor level However if you must raisetheairregisterabovethefireplacelevel you will have to make a loop to the floor with the flexible pipe to prevent from causing a draft in the outside air re...

Страница 10: ...mensions Notes Due to Lennox Hearth Products ongoing commitmenttoquality allspecifications ratings and dimensions are subject to change without notice All framing dimensions calculated for 1 2 dry wal...

Страница 11: ...hermostat in the room where the fireplace is located Acoolingthermostatcanbeinstalledinthe same room as the unit This thermostat will turn on the blower when the room where the fireplace is located be...

Страница 12: ...with combustible materials or damage the chimney Figure 14 Insulate Joists Same As Ceiling Draft Stops Firestop CTDT Termination Note Non Combustible Chase Flashing Must Be Used To Cover Chase Openin...

Страница 13: ...ach the desired height Every time the chimney passes through a roof or a wall install the appropriate firestop When you reach the desired height install the roof support see instructions included with...

Страница 14: ...hing Flashing Collar Rain Cap Support Radiation Shield AC Air Cooled Chimney Start ing Piece Note The Outside Air Kit is Mandatory Outside Combustion Air Kit UZI AC Model Air Cooled Insulated Galvalum...

Страница 15: ...E SLOPE ASHT S 2100 AC 8 8 8 14 3 8 365mm 16 406mm 15 380mm 2 12 14 5 8 371mm 16 1 4 413mm 15 3 8 390mm 4 12 15 1 4 387mm 16 7 8 429mm 16 1 8 410mm 6 12 16 1 8 410mm 17 7 8 454mm 16 7 8 430mm 8 12 17...

Страница 16: ...d previously 5 From below install a radiation shield see Figure 17B 6 Continue with the regular installa tion Note When using AC chimney an AC8SB starter section must be used before installing an elbo...

Страница 17: ...13 16 122mm 6 1 8 156mm 11 280mm 14 1 8 359mm 16 7 8 429mm 18 7 16 468mm 23 584mm 26 3 16 665mm B 27 11 16 703mm 33 1 2 851mm 50 7 8 1292mm 62 1 2 1588mm 72 5 8 1845mm 78 7 16 1992mm 95 3 4 2432mm 107...

Страница 18: ...installation for Canada only In cold climate locations we recommend that youusetheinsulatedwallradiationshieldsince it will maintain the home s thermal barrier Figure 22 ANGLE WALL RADIATION SHIELD I...

Страница 19: ...e a wall this support may be used on the wall to support the chimney The maximum heights are given in Table 7 For offset support installation refer to the instructions provided with the support Figure...

Страница 20: ...at elevations above 4000 feet or in cold climates where temperatures are likely to fall below 32 F 0 C When using AC chimney an AC8SB starter section must be used before installing an elbow When an of...

Страница 21: ...to Convert Fireplace for Use with AC Chimney Starter Section adaptor 8 AC AC8SB H3801 Starter 30 Elbow 8 AC AC8SB30 H3802 Outside Air Kit Required for AC Chimney Installations Chimney Outside Air Kit...

Страница 22: ...PR SR2798 Touch up Paint Aerosol Black Metallic SBMB6309 70K99 Replacement parts LIST ME43 CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation Side...

Страница 23: ...NOTES 23...

Страница 24: ...r a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your Lennox Hearth Products distributor or dealer Parts will be shipped...

Отзывы: