Lennox Hearth Products Elite EDVI25 Скачать руководство пользователя страница 2

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

2

Installation must conform to local codes. In 
the absence of local codes, installation must 
comply with the current National Fuel Gas 
Code, ANSI Z223.1. (In Canada, the current 
CAN-1 B149 installation code.)  Electrical 
wiring must comply with the National Electri-
cal Code ANSI/ NFPA 70 - latest edition.  In 
Canada, the current CSA C22-1 Canadian 
Electrical Code - latest edition.

TABLE OF CONTENTS 

Packaging ......................................page  2
Introduction ...................................page  2
General Information .......................page  3
Questions/Building Offi cials ...........page  4
High Altitude ..................................page  4
Fireplace Requirements ..................page  4
Specifi cations .................................page  5
Clearance to Combustibles .............page  7

Step 1 Clean Fireplace ........................page  8
Step 2 Preparation ...........................page 8
Step 3 Unpack the insert. ...................page  8
Step 4 Lift Insert into Position ...........page  8
Step 5 Remove Glass Door ................page  8
Step 6 Remove Firebox Contents ......page  9
Step 7 Install LP Conv. (if necessary) page  9
Step 8 Install Venting .........................page  9
Step 9 Connect Gas Line ....................page  11
Step 10 Purge Air ...............................page  11

Step 11 Install Log Set .......................page  11
Step 12 Perform Leak Test .................page  14
Step 13 Install Opt. Surround or 
Control Kit ...........................................page  14
Step 14 Install Thermostat/Remote ...page  14
Step 15 Check Appliance Operation ...page  14
Step 16 Reinstall Front Glass Door ....page  14
Step 17 Check Blower Operation .......page  14
Step 18 Adjust Burner  .......................page  15
Step 19 Install Optional Accessories ..page  15
Rating Plates .......................................page  16

Please read and understand these 
instructions before beginning your 
installation.

This installation manual will help you obtain 
a safe, effi cient, dependable installation for 
your appliance and vent system. 

CONGRATULATIONS ON THE PURCHASE OF YOUR NEW GAS APPLIANCE MANU-
FACTURED BY LENNOX HEARTH PRODUCTS.

 

When you purchased your new gas fi red heater, you joined the ranks of thousands of 

concerned individuals whose answer to their home heating needs refl ects their concern for 
aesthetics, effi ciency and our environment. We extend our continued support to help you 
achieve the maximum benefi t and enjoyment available from your new gas fi red heater. It 
is our goal at Lennox Hearth Products to provide you, our valued customer, with an appli-
ance that will ensure you years of trouble free warmth and pleasure. 
 

Thank you for selecting a Lennox Hearth Products gas fi red heater as the answer to 

your home heating needs.

Sincerely, 
All of us at Lennox Hearth Products

These Millivolt appliances are listed by 
OMNI-Test Laboratories Inc. for instal-
lation in bedrooms and manufactured 
(mobile) homes.

PACKAGING LIST

The assembled vented gas insert heater is 
packaged with:
1 -  One accessory package containing a 
literature package (installation and operation 
instruction manuals) is located on top of the 
appliance.
2 -  One log set, one bag of embers, one bag 
of vermiculite, one propane conversion kit (if 
needed to run on LP gas).
3 -  One Warranty Certifi cate.
4 -  One Fireplace Warning Label.

When installed in a manufactured home (mobile 
home), these appliances must be installed 
in accordance with the current Standard for 
Mobile Homes, CAN/CSA Z240 MH, or with the 
Manufactured Home Construction and Safety 
Standard, Title 24 CFR, Part 3280, or when 
such a standard is not applicable, the current 
Standard for Fire Safety Criteria for Manufactured 
Home Installations, Sites and Communities, 
ANSI/NFPA 501A.

These millivolt appliances are designed to 
operate on natural or propane gas only.

 Units 

are factory set for use with Natural Gas and will 
require  fi eld conversion for use with Propane 
(a propane conversion kit is located inside the 
fi rebox).  The use of other fuels or combination 
of fuels will degrade the performance of this 
system and may be dangerous. 

These appliances comply with National 
Safety Standards and are tested and listed 
by OMNI-Test Laboratories Inc.; Beaverton, 
Oregon (Report No. 116-F-14-5) to ANSI 
Z21.88 (in Canada, CSA-2.33), and CAN/
CGA-2.17-M91 in both USA and Canada, as 
vented gas heaters.  

These heaters are designed to be installed into 
an existing masonry fi replace (built to UBC 37  
or   ULC S628 standards) or factory built solid 
fuel, wood, burning fi replace (listed to UL 127 
or ULC S610) only. All exhaust gases must be 
vented outside the structure.  Combustion air 
is drawn from outside the structure. 

These appliances use a millivolt type control 
system consisting of a gas control valve with 
regulator (control to adjust for fl ame appear-
ance and heat output), a standing pilot burner 
assembly, a thermopile, thermocouple, a piezo 
igniter, and ON/OFF switch. 

THE GAS BURNER 

SYSTEM ON THESE APPLIANCES DO NOT 
REQUIRE 120 VOLT POWER TO OPERATE.

These appliances are designed as supple-
mental heaters. Therefore, it is advisable to 
have an alternate heat source when installed 
in a dwelling. 

SURROUND ASSEMBLY SOLD 
SEPARATELY 

Model: EDVI25

SKS-25 Surround Kit, Small 
 

(40 1/4" W x 26 1/4" H)

SKM-25, Surround Kit, Medium 
 

(44 1/8" W x 28 1/8" H)

Model: EDVI30

SKS-30, Surround Kit, Small 
 

(40 1/4" W x 27 1/2" H)

SKM-30, Surround Kit, Medium 
 

(45 3/4" W x 30 1/4" H)

SKL-30, Surround Kit, Large 
 

(49 1/4"" W x 32" H)

Model: EDVI35

SKM-35, Surround Kit, Medium 
 

 

(48 1/16" W x 34 1/16")

DO NOT ATTEMPT TO ALTER OR MODIFY 
THE CONSTRUCTION OF THE APPLIANCE OR ITS 
COMPONENTS. ANY MODIFICATION OR ALTERA-
TION MAY VOID THE WARRANTY, CERTIFICATION 
AND LISTINGS OF THIS UNIT.

INTRODUCTION

  

The Insert models covered in this manual are 
Direct-Vent sealed combustion gas heaters 
designed for residential application for installion 
into an existing masonry or factory built solid 
fuel burning fi replace. The required liners for 
the air intake and exhaust are as follows:
• 

Air Intake: U

se 3” diameter UL 1181 or UL 

1777 listed liner only.

• 

Exhaust: Use 3” diameter UL1777 listed 

gas vent liner only.

  DO NOT USE UL 1181 

LISTED LINER.

These vent systems must be routed through 
the existing fi replace fl ue system to the vent 
termination.

Содержание Elite EDVI25

Страница 1: ...USINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY Do not store or use gasoline or other flammable s or liquids in the vicinity of this or any other appliance FOR YOUR SAFETY What to...

Страница 2: ...ropane conversion kit if needed to run on LP gas 3 One Warranty Certificate 4 One Fireplace Warning Label Wheninstalledinamanufacturedhome mobile home these appliances must be installed in accordance...

Страница 3: ...TO THE FLU WITH HEAD ACHES DIZZINESS AND OR NAUSEA IF YOU HAVE THESE SIGNS OBTAIN FRESH AIR IMMEDIATELY TURN OFF THE GAS SUPPLY TO THE APPLIANCE AND HAVE IT SERVICED BY A QUALIFIED PROFES SIONAL AS IT...

Страница 4: ...or Regional Gas Codes National Fuel Gas Code 2 Local amendments 3 Recognized testing lab OMNI Test Labo ratories Inc Beaverton Oregon 4 Is a permit required cost 5 Insomestatesormunicipalities alicen...

Страница 5: ...DVI25 Steady State Efficiency 65 NG 66 LP 86 NG 89 LP 110 cfm 5 127 mm 19 1 2 483 mm 1 15 16 49 mm 10 9 16 268 mm 9 5 8 224 mm 1 1 4 32 mm 26 5 8 676 mm 20 1 2 521 mm 14 356 mm N B A D E F C J 17 1 4...

Страница 6: ...BTU hr Input LP 22 000 to 28 000 26 000 to 34 000 Co linear DV Vent Size 3 Dia Liner exhaust intake 3 Dia Liner exhaust intake Room Blower CFM EFFICIENCIES EDVI30 EDVI35 Steady State Efficiency 87 NG...

Страница 7: ...in Min Min Min Min Min MAX MAX Min Max See Fig 3 4a 0 0 mm 0 0 mm 16 406 mm 16 406 mm 49 1245 mm 48 1219 mm 50 1270 mm 49 1245 mm 36 914 mm 36 914 mm 8 203 mm 8 203 mm 64 1626 mm 64 1626 mm See Fig 3...

Страница 8: ...om of Door outward Figure 11 WARNING NEVER OPERATE UNIT WITH OUT THE FRONT GLASS DOOR PANEL IN PLACE AND SECURE DETAILED INSTALLATION STEPS Step 2 PREPARATION Plan and install gas line These appliance...

Страница 9: ...ec tor Plate Screw Guide Hose Clamps After liners are secured to collars slide liner con nector plate forward and secure with screw Flex Liner Installation Air Inlet Liner for combus tion air When ter...

Страница 10: ...ure 15 Roof Flashing See Direct Vent System Components on Page 9 Use 3 diameter listed liner UL1181 or UL1777 for the AIR INTAKE Use 3 diameter listed liner UL1777 ONLY for the EXHAUST Use 3 diameter...

Страница 11: ...NSTALLING LOGS VERMICU LITE AND EMBERS Thepackagedlogset vermiculiteandembers are located within the firebox of the insert Note The EDVI25 EDVI30 log set is shown in figures 20 28 and the EDVI35 log s...

Страница 12: ...ins and or log stoppers This will ensure a proper flame and safe combustion 1 Place the largest log onto the 2 corresponding locating pins at the back of the firebox as shown in Figure 20 Figure 20 2...

Страница 13: ...entations on Front Center Log and front right twig as shown in Figure 26 Figure 26 Front Center Log Top Right Log Figure 27 Figure 28 Embers Vermiculite Carefully install the seven piece log set into...

Страница 14: ...wn in Figure 34 One package of ember material has been included with this log set You will not need to use the entire bag IMPORTANT The quantity and placement of the ember material can affect stove pe...

Страница 15: ...TLET DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG IT MUST BE ROUTED TO AVOID CONTACT DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE With gas line installed run initial system checko...

Страница 16: ...not soot the shutter opening must be adjusted between these two extremes No smoke or soot should be present Repo sition the logs if flames impinge on any of them If the logs are properly positioned a...

Страница 17: ...N 9 1467B SERIAL NUMBER NOMBRE DE SERIE XXX XXX IIIIIIIIIIIIIIIIIIII XXX P N 9 1467B DU DESSUS DE L APPAREIL 12 203mm 305mm Cat No H0921 MAX MAX MODEL NO EDVI30 MANUFACTURED AT Union City TN FOR USE W...

Страница 18: ...EL FOR INSTALLATION IN SOLID FUEL FIREPLACES THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS FOYER AU GAZ CHAUFFANT AVEC EVACUATION NE DOIT PAS ETRE UTILISE AVEC UN COMBUSTIBLE SOLIDE...

Страница 19: ...19 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTE THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 20: ...P N 775 156M REV G 3 2005 Lennox reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult you...

Отзывы: