background image

3

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning are similar to
the flu with headaches, dizziness and/or
nausea. If you have these signs, obtain
fresh air immediately. Turn off the gas sup-
ply to the appliance and have it serviced by
a qualified professional, as it may not be
operating correctly.

Figure 1

WARNING:  FAILURE TO COMPLY
WITH THE INSTALLATION AND OPER-
ATING INSTRUCTIONS PROVIDED IN
THIS DOCUMENT WILL RESULT IN AN
IMPROPERLY INSTALLED AND OP-
ERATING APPLIANCE, VOIDING ITS
WARRANTY. ANY CHANGE TO THIS
APPLIANCE AND/OR ITS OPERATING
CONTROLS IS DANGEROUS.  IM-
PROPER INSTALLATION OR USE OF
THIS APPLIANCE CAN CAUSE SERI-
OUS INJURY OR DEATH FROM FIRE,
BURNS, EXPLOSION OR CARBON
MONOXIDE POISONING.

WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE HAZ-
ARDS OF HIGH SURFACE TEMPERA-
TURES. USE CAUTION AROUND THE
APPLIANCE TO AVOID BURNS OR
CLOTHING IGNITION. YOUNG CHIL-
DREN SHOULD BE CAREFULLY SUPER-
VISED WHEN THEY ARE IN THE SAME
ROOM AS THE APPLIANCE.

AVERTISSEMENT: SURVEILLER LES
ENFANTS.  GARDER LES VÊTEMENTS,
LES MEUBLES, L'ESSENCE OU AUTRES
LIQUIDES  À VAPEUR INFLAMMABLES
LOIN DE L'APPAREIL.

Any safety guard or screen removed for ser-
vicing the appliance must be replaced prior to
operating the appliance.

Table 1

Tables 1 shows the units' gas orifice size
for the elevations indicated.

The appliance and its individual shut-off valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at pressures in excess of 1/2 psig
(3.5 kPa).

Access

Cover

Control
Valve

Refractory

Cover

The appliance must be isolated from the gas
supply piping system (by closing its individual
manual shut-off valve) during any pressure test-
ing of the gas supply piping system at test pres-
sures equal to or less than 1/2 psig (3.5 kPa).

WARNING: DO NOT PLACE CLOTHING
OR OTHER FLAMMABLE MATERIALS
ON OR NEAR THIS APPLIANCE.

Units are tested and approved for elevations
of 0 to 4500 feet (0 to 1372 meters).

For elevations above 4500 feet (1372
meters), install the unit according to the
regulations of the local authorities having
jurisdiction and, in the USA, the latest
edition of the National Fuel Gas Code (ANSI
Z223.1) or, in Canada, the latest edition of
the CAN1-B149.1 and .2 codes.

Maximum manifold pressure is 3.5 in. w.c.
(0.87 kPa) for natural gas and 10 in. w.c. (2.49
kPa) for LP/Propane gas.

The minimum manifold pressure on low is 2.2
in. w.c. (0.55 kPa) for natural gas and 6.3 in.
w.c. (1.57 kPa) for LP/Propane gas.

Do not use these appliances if any part has
been under water. Immediately call a qualified,
professional service technician to inspect the
appliance and to replace any parts of the
control system and any gas control which
have been under water.

Ne pas se servir de cet appareil s'il a été plongé
dans l'eau, complètement ou en partie.  Appeler
un technicien qualifié pour inspecter l'appareil
et remplacer toute partie du système de
contrôle et toute commande qui ont été plongés
dans l'leau.

Test gage connections are provided on the
front of the electronic gas control valve (iden-
tified OUT for the manifold side and IN for inlet
pressure.  A 1/8" NPT test gage connection is
provided on the electronic gas control valve
adjacent to the outlet to the main burner.

Minimum inlet gas pressure to these appli-
ances is 5.0  inches water column (1.24 kPa)
for natural gas and 11 inches water column
(2.74 kPa) for propane for the purpose of input
adjustment.

Maximum inlet gas supply pressure to these
appliances is 10.5 inches water column (2.61
kPa) for natural gas and 13.0 inches water
column (3.23 kPa) for propane.

Model

No.

Orifice size

Elevation

Feet

(meters)

Natural

Gas

Propane

E36ODG

0.1405"

(#28)

0.0785"

(#47)

0-4500

(0-1372)

E42ODG

0.1405"

(#28)

0.0785"

(#47)

Содержание ELITE E36ODGNE

Страница 1: ...ivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service dos incendies L installationetservicedoitêtreexécutéparunqualifié installeur agencedeserviceoulefournisseurdegaz A French manual is available upon request Order Form Number 875 032CF Ce manuel d installation est disponible en francais simplement en faire la demande Numéro de la pièce 875 032CF...

Страница 2: ... DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUPPLIER These appliances comply with National Safety Standards and are tested and listed by Omni Test Laboratories Report No 116 F 41 5 to CSA 4 96 in Canada CR97 003 and CAN CGA 2 17 M91 in both USA and Canada as an outdoor gas fireplace The Installation must conform to l...

Страница 3: ... system at test pres sures equal to or less than 1 2 psig 3 5 kPa WARNING DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIALS ON OR NEAR THIS APPLIANCE Units are tested and approved for elevations of 0 to 4500 feet 0 to 1372 meters For elevations above 4500 feet 1372 meters install the unit according to the regulations of the local authorities having jurisdiction and in the USA the latest edition o...

Страница 4: ...ntAccess The gas controls can be found beneath the bottom refractory Remove the bottom refrac tory by lifting it up Remove the access cover refer to Figure 1 All Models To light these appliances refer to the detailed lighting instructions found in both English and French on pages 14 and 15 of these instruc tions respectively The appliance lighting in structions may also be found on the pull out li...

Страница 5: ...ck Ember Materials Replace Spent Batteries Qualified Service Technician Qualified Service Technician Qualified Service Technician Homeowner Qualified Services Technician Homeowner Inspect valve and ensure it is properly operat ing Check piping for leaks Vacuum the controlcompartment fireplacelogsandburner area Refer to Figure 7 Dexen on page 8 Remove anysurfacebuild uponpilotandburnerassem bly Wip...

Страница 6: ... air shutter opening on the main burner tube should be adjusted Keep in mind that this is an outdoor appliance Wind and air currents cannot be strictly controlled If the flame acts too erratically we recommend that the screens be closed Burner Adjustment CAUTION THE SHUTTER AND NEARBY AP PLIANCE SURFACES ARE HOT EXERCISE CAUTION TO AVOID INJURY WHILE ADJUST ING FLAME APPEARANCE Toadjusttheflame tu...

Страница 7: ...omponents in place Use two 2 bags of lava rock to fill the bottom of the burner tray to completely cover the burner tube Level the rock evenly Place the rear log approximately centered as shown in Figure 5 Place the base log approximately as shown in Figure 6 The remaining logs can be placed across the rear and base log approximately as shown in Figure 7 The exact position of these logs is not cri...

Страница 8: ...ption H4645 36LBFOD BS 36 Otdr B F Door Brshd SS H4646 42LBFOD BS 42 Otdr B F Door Brshd SS Outdoor Weather Cover This attractive Outdoor Weather Cover is easy to install and protects the firebox interior from adverse weather Outdoor Weather Cover Cat No Model Description H4647 36 EODC 36 SS Otdr Weather Cover H4648 42 EODC 42 SS Otdr Weather Cover Hood Kit This attractive Hood Kit is easy to inst...

Страница 9: ...800 9 LENNOX Your Fireplace s Model Number _______________________________________ Your Fireplace s Serial Number ________________________________________ The Date On Which Your Fireplace Was Installed __________________________ The Type of Gas Your Fireplace Uses ___________________________________ Your Dealer s Name_________________________________________________ When ordering repair parts alwa...

Страница 10: ... if service e is to be performed or for extended shutdown TO TURN OFF GAS TO APPLIANCE LIGHTING INSTRUCTIONS 1 STOP Read the safety information above on this page 2 Turn remote wall switch to OFF 3 This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand 4 Allow sufficient length of time minimum 5 minutes for any gas in the combu...

Страница 11: ...a position arrêt OFF ou placez le thermostat à la plus basse température 2 Coupez l alimentation électrique du foyer et retirez les batteries de sécurité si vous prévoyez faire le service de l appareil ou si vous ne l utilisez pas à long terme 1 ARRÊTEZ Lisez les consignes de sécurité au verso de cette plaque 2 Tournez l interrupteur mural à distance à la position arrêt off ou placez le thermostat...

Страница 12: ...nings Reset the limit switch Check the burner pan for the proper application of lava rock A Dead batteries B Low voltage or bad lead wires C Damaged igniter wire D Damaged pilot assembly A No fuel supply B Loose sensor wire C Lose wires to valve D Loose wires to ignition module E Air in the gas line F Low voltage A Gas supply is turned OFF B Loose wire connection on valve or ignition module C Flam...

Страница 13: ...13 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES ...

Страница 14: ...8 s a G l a r u t a N y l b m e s s A n i a r T s a G 1 4 9 4 H 1 1 4 9 4 H 1 B 8 s a G e n a p o r P y l b m e s s A n i a r T s a G 2 4 9 4 H 1 2 4 9 4 H 1 9 y l b m e s s A r e v o C e v l a V 7 4 9 4 H 1 7 4 9 4 H 1 0 1 e m a r F p o T 3 3 9 4 H 1 4 3 9 4 H 1 1 1 e m a r F m o t t o B 5 3 9 4 H 1 6 3 9 4 H 1 2 1 H L t s o P r e n r o C 7 3 9 4 H 1 7 3 9 4 H 1 3 1 H R t s o P r e n r o C 8 3 9 ...

Страница 15: ...15 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS 13 12 4 17 18 3 14 5 6 11 3H 16 15 1 2 1H 2H 7 RIGHT SIDE RIGHT SIDE 8A 9 10 8B 21 19 20 22 ...

Страница 16: ...75 032M REV C 09 2008 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1110 West Taft Avenue Orange CA 92865 ...

Отзывы: