TROUBLESHOOTING 

 

PAGE 18 

OVERFIRING DAMAGE 

If the heater or chimney connector glows, you are overfir-
ing. Other symptoms may include: Cracking, warping or 
burning out of components, stove glass may develop a 
haze, which will not come off with cleaning. 
 
Overfiring of a stove is a condition where excessive tem-
peratures are reached, beyond the design capabilities of 
the appliance. The damage that occurs from overfiring is 
not covered under the manufacturer’s limited warranty. 
 
The following are a few conditions that should be evalu-
ated and (corrected if necessary) if an overfiring condi-
tion is suspected: 

 
Overfiring Caused From Improper Installation

 - En-

sure that all installation requirements have been met as 
outlined in the installation manual. The chimney should 
be clean and in good repair. A draft test should be per-
formed to determine if the draft requirements of the ap-
pliance are being met. A draft gauge should read be-
tween .05 and .07 inches water column (" W.C.). Exces-
sive draft (above .07 " W.C.) will allow too much combus-
tion air to be pulled in which results in hotter burns. Too 
little draft (below .05 " W.C.) will not allow enough com-
bustion air delivery to maintain a fire (this may result in 
improper operation of appliance, i.e. won't maintain fire 
unless fuel door is left open. See 

Care and Operation

 

section). 

Overfiring Caused From Improper Operation

 - Oper-

ate this appliance only as outlined in this manual. Never 
burn the appliance with the fuel door open or ajar. Do not 
operate this stove with the Air Control in the "open" posi-
tion (pulled out) for extended periods.  This wastes fuel 
and can cause dangerous overfiring conditions. NEVER 
leave the stove unattended on high settings. 
 

Overfiring Caused From Improper Maintenance

 - 

Strictly adhere to all maintenance requirements at fre-
quent intervals as prescribed in this manual including 
cleaning of flue and stove. Should the fuel door gasket or 
glass gasket become worn or damaged, it should be re-
placed. 
 

Overfiring Caused From Improper Fuel

 - This appli-

ance is approved for use with natural dry well seasoned 
wood only (ask your authorized dealer what are ap-
proved fuels for your area). Do not burn garbage, parti-
cleboard scraps, or pressed logs using bonding agents 
because they can produce conditions that will deteriorate 
metal. Do not overload or use kindling wood or mill ends 
as primary fuel as this may cause overfiring. 

Содержание EARTHSTOVE 1400HT

Страница 1: ...NUAL THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER READ ENTIRE MANUAL THOROUGHLY BEFORE INSTALLATION P MODEL 1400HT P N 775000M Rev G 12 03 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE EPA CERTIFIED WOOD BURNING STOVE ...

Страница 2: ... use gasoline gasoline type lantern fuel kerosene charcoal lighter fluid or similar liq uids to start or freshen up a fire in this heater Keep all such liquids well away from the heater while it is in use 10 DO NOT OVERFIRE If heater or chimney con nector glows you are overfiring Overfiring this appliance could cause a house fire Overfiring is a condition where the appliance is operated at tempera...

Страница 3: ...d your new woodstove you joined the ranks of thousands of concerned indi viduals whose answer to their home heating needs reflects their concern for aesthetics efficiency and our environment We extend our continued support to help you achieve the maximum benefit and en joyment available from your new wood stove It is our goal at Lennox Hearth Products to provide you our valued customer with an app...

Страница 4: ...ing department for requirements in your area NOTE This appliance is NOT approved for installa tion into a Manufactured Mobile Home in Canada SELECTING A LOCATION The design of your home and where you place your stove will determine its value as a source of heat A wood stove depends primarily on air circulation con vection to disperse its heat and therefore a central location is often best There ar...

Страница 5: ...learance Using Approved L Vent only Approved brands are Dura Vent Security Pro Vent and Ameri Tek Manu factured Mobile Home installations must use a rain cap with a spark arrester Clearances inches millimeters A 10 267 C 15 381 E 9 241 B 20 508 D 8 203 F 5 127 CORNER INSTALLATION PARALLEL INSTALLATION ALCOVE CLEARANCE Required pipe Type L Vent pipe to top of stove Ap proved brands are Dura Vent Pr...

Страница 6: ... USA Requirements 16 406 mm min to the front of the fuel door glass 8 203 mm min beyond the sides of the fuel door opening Canada Requirements 18 457 mm min to the front of the fuel door glass 8 203 mm min beyond the sides of the stove body STANDARD PARALLEL HEARTH PAD SHOWN PROTECTED WALL CLEARANCE Some local codes will allow reduced clearances when the stove is installed adjacent to a protected ...

Страница 7: ...e legs Mark holes then remove the stove Drill the 4 four holes with a 1 4 7 mm drill bit Drill down through the floor protector and the manufactured mobile home floor Use 1 4 7 mm lag bolts and secure to the manufactured mobile home floor NOTE If the composition of the manufactured mobile home floor is of light particleboard construction you will be required to secure the stove with regular hex he...

Страница 8: ...Built Chimney This space heater is to be connected to a factory built chimney conforming to CAN ULC S629 Standard for 650 C Factory Built Chimneys For Reduced Residential Clearances Type L and listed double wall connector pipe is acceptable Install any factory built brand of pipe according to the manu facturer s instructions Vapor Barrier at Chimney Penetration Install all venting components per t...

Страница 9: ...adjacent structures addi tional chimney height or a special chimney cap may be required to ensure optimum performance The 2 by 10 Rule for Vent Termination For Manufactured Mobile Homes Only Portions of the chimney and termination that exceed an elevation of 13 feet above ground level may be designed to be removed for transporting the manufactured mobile home Requires A Listed Termination Cap 2 61...

Страница 10: ...ipe per the draft gauge manufacturers instructions to create a draft test port Note Hole location should be a minimum of 1 foot above flue outlet collar 4 Start a fire See How To Start And Maintain A Fire on page 16 5 After the fire is well established 20 25 minutes and burning at a low setting perform the draft test per the gauge manufacturer instructions The draft gauge should read between 05 an...

Страница 11: ...e IMPORTANT NOTES Minimize the use of elbows 30 45 or 90 Offsets in the venting system are very restrictive and will inhibit the draft i e You will lose approximately 5 feet of effective draft for every 90 degrees of direction change This appliance requires 12 to 15 feet of effective draft for optimum performance see Draft Requirements on page 10 First section of pipe must be vertical Use as much ...

Страница 12: ...lation from the outer surface of the wall thimble to wall combustibles Support the wall thimble and cover its opening with a 24 gage minimum sheet metal support Maintain the 6 152 4 mm space There should also be a support sized to fit and hold the metal chimney connector See that the supports are fastened securely to wall surfaces on all sides Make sure fasteners used to secure the metal chimney c...

Страница 13: ...RESS ON HINGE AREA OF DOOR AND HINGE PINS AND MAY RESULT IN BREAKAGE DOOR OPERATION The door handle assembly opens and securely latches the fuel door closed To open the door rotate the coil handle to the 9 00 position until door releases To close and latch hold the coil handle in the 9 00 position close the door then rotate the handle to the 6 00 position See illustration above GLASS The Glass is ...

Страница 14: ...ter in color Eventually the entire surface will become an even color Once the paint has been softened and cooled two or three times it will harden Do not turn on a blower during the curing process Do not place anything on the stove surface until the paint is completely cured Do not attempt to repaint the stove until the paint is completely cured If the surface later becomes stained or marred it ma...

Страница 15: ... 12 months to 24 months Logs that are 5 127 mm diameter across or larger should be split in half three pieces if over 8 inches 203 mm and four pieces when over a foot 305 mm across If the tree fell 2 to 4 years ago it still needs to be cut split and sea soned for 6 to 24 months depending on the wood WOOD STORAGE Wood to be seasoned should be stacked in an area open enough to ensure good air circul...

Страница 16: ... in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an ex tremely hot fire Also creosote deposits tend to form in long runs of venting where gases become too cool prior to exhausting Note Single wall pipe cools rapidly there fore installations using this type of flue are more suscep tible to creoso...

Страница 17: ...r switch 4 The area to heat is too large square foot heating esti mates are based on average climates and home de sign 5 There is an obstruction in the chimney The chimney or chimney cap is restricted by creosote preventing enough draw to sustain a high heat output rate DOES NOT MAINTAIN A FIRE 1 Soft wood does not burn as long or as well as seasoned hardwood resulting in a short burn time 2 Wood ...

Страница 18: ...le draft below 05 W C will not allow enough com bustion air delivery to maintain a fire this may result in improper operation of appliance i e won t maintain fire unless fuel door is left open See Care and Operation section Overfiring Caused From Improper Operation Oper ate this appliance only as outlined in this manual Never burn the appliance with the fuel door open or ajar Do not operate this s...

Страница 19: ...eet 564 cubic mm Maximum Burn Rate BTU 58 730 EPA BTU Range 11 700 37 000 EPA Efficiency 63 Emissions Rate grams hour 6 6 gph Loading Front Approx weight with brick 285 lbs 130 kg Blower Optional 160 CFM 9 amp W speed control Rheostat 75v 110v Note Dimensions shown are approximations only 6 4 mm Square feet square meters heating capacity and burn time are approximations only They will vary dependi...

Страница 20: ...26M28 Module Assembly Draft flame height control Firebox Parts see firebrick diagram page 20 note all firebrick are 1 thick FB 1 Firebrick 9 x 4 1 2 FB 2 Firebrick 9 x 4 1 2 w notch 10545 Firebrick 9 x 4 1 2 w notch baffle brick are a special denser brick Do not substitute with FB 2 FB11 Firebrick 4 1 2 x 4 3 8 FB5 Firebrick 9 x 2 1 2 w hole Fan System Parts if optional kit s installed 14440 Dial ...

Страница 21: ...BLY HANDLE ASSEMBLY P N LB 102214 PRIMARY AIR DRAFT MODULE FB 1 FB 1 FB 1 FB 1 FB 1 FB11 FB 1 FB 2 FB 2 FB 2 FB 2 FB 2 FB 2 Must Chip Approximately 1 x 1 Notches to Fit FB 2 FB 2 FB 2 FB5 FB 2 Baffle Brick 5 ea P n 10545 Torque Plate Nut Washers Handle Rod Coil Handle ...

Страница 22: ...r can be delivered for combustion air by utilizing this floor penetration duct Duct penetration measures 3 76 mm diameter round Blower Kit A Blower Kit includes rheostat for variable speed control is available for increased heat circulation Variable Speed Control Dial A Temp Stove Stat Kit Turns blower on when stove is hot and turns blower off when stove is cool Plug Dial A Temp into Wall Outlet P...

Страница 23: ...SAFETY LISTING LABEL PAGE 23 ...

Страница 24: ...EPA LABEL PAGE 24 ...

Страница 25: ...e 25 OWNERSHIP RECORDS Dealer s Name Dealer s Address City State Zip Code Serial Number Date of Purchase Date Installed Notes SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Description ...

Страница 26: ...1110 West Taft Avenue Orange CA 92865 ...

Отзывы: