Lennox Hearth Products CANYON C310 Скачать руководство пользователя страница 11

11

Install the two 3” (76 mm) long bolts (with the head up) through the 
nuts attached to the insert on the lower rear corner of each side. This will 
allow you to level the insert when placed into the fireplace. Measure from 
the front of the top surround mount to the center of the flue. Determine 
if there is an alignment problem in connecting a liner from the chimney 
to the insert’s flue. If there is an alignment problem, connection can be 
made using a short piece of stainless flex or a stainless steel offset box 
(available from your dealer). Before installing the liner, make any attach-
ment brackets or drill any holes in the liner, offset box, or insert. Once 
installed, it may be difficult or impossible to drill additional holes.

If additional support is necessary, factory punched holes in the front 
corners of the bottom air chamber will accept leveling legs. Carefully 
measure the distance from the hearth protection to the bottom of the 
stove. Use 3/8” diameter bolts that are 1/2” (13 mm) longer that the 
distance just measured. Thread a nut onto the the bolt approximately 1” 
(25 mm). Lift the stove slightly and insert a bolt into each hole and then 
thread the nut up the bolt until the front is securely supported. Install 
another nut onto the bolt through the air space in the stove and tighten 
securely. If desired an insert front support, Cat. No. H5296, is available 
to fill the space between the insert and the hearth protection.

Install the brick and baffle as per 

Page 6

.

INSERT PRE-INSTALLATION PREPARATION

Place the insert into the fireplace, making sure to center it side to side. 
Slide the insert in until the surround mounts are approximately 1/2” (13 
mm) from the face of the fireplace where the surround panels cover.

Lower the chimney and make attachment to the insert. Level the stove 
by using a 3/4” socket and a long extension and adjusting the bolts on 
either side of the insert.

Install the side surround panels with the screws supplied. Push the insert 
in until there is approximately a 1/4” (6 mm) gap between the back of the 
surround panels and the face of the fireplace. Before installing the top 
surround panel, make sure all connections are tight and that no part of 
the insert or chimney is touching the firebox or chimney in the fireplace. 
There must be a minimum of  1” (25 mm) clearance between the stove 
and the zero clearance fireplace. Install the top surround panel.

Remove the existing chimney cap and install a stainless steel liner into 
the chimney (if a special section has been used or drilled to attach to the 
insert, it must be the bottom piece). The next piece should be a dripless 
slip joint; followed by the rest of the chimney liner. Fasten the chimney 
at the top when it is positioned so that the slip joint will allow the lowest 
piece to slide up enough to clear the insert during installation. Insulate 
the top four to six feet between the liner and the chimney to prevent heat 
loss. Install the cap and flash if necessary to prevent water or creosote 
from entering the chimney’s venting system.

From inside the fireplace firebox, attach any adapters or flue offsets and 
slide the liner up as far as necessary for the bottom piece to clear the 
insert during installation.

INSTALLING THE INSERT

CHIMNEY LINER INSTALLATION

1.  Check that all chimney pipe joints are securely fastened.

2.  Check that the heater is securely fastened to the floor (if ap-

plicable).

3.  Make sure the intake vent has clear access to outside air (if ap-

plicable).

4.  Make sure the outside air vent has been sealed properly to keep 

rodents out (if applicable).

5.  Be sure all roof flashings are watertight (if applicable).

6.  Be sure the stove is properly grounded (if applicable).

FOR YOUR OWN PROTECTION AND INSURANCE PURPOSES, 

HAVE YOUR CHIMNEY AND CONNECTOR PIPE INSTALLATION 

INSPECTED BY YOUR LOCAL BUILDING CODE AUTHORITY OR 

FIRE MARSHAL BEFORE STARTING A FIRE IN YOUR STOVE. 

NOTIFY YOUR INSURANCE COMPANY. 

POST INSTALLATION CHECKS

Содержание CANYON C310

Страница 1: ...implement en faire la demande Num ro de la pi ce 775 213CF Theseappliancesmustbeproperlyinstalledandoperatedinordertopreventthe possibility of a house fire Please read this entire installation and ope...

Страница 2: ...Curing 5 Brick Installation 6 Required Clearances 7 Hearth Protection 8 Chimney Requirements 9 Installation Procedures Masonry Chimney 9 Positive Flue Connection 10 Insert Pre Installation Preparation...

Страница 3: ...nth during the burn ing season to check for soot and creosote accumulations Any accumulations over 1 4 thick should be removed by a professionalchimneysweep Donotattempttoburnoutheavy creosoteaccumula...

Страница 4: ...verfiringofafireplaceinsertisaconditionwhereexcessivetemperatures are reached beyond the design capabilities of the appliance The dam age that occurs from overfiring is not covered under the manufactu...

Страница 5: ...ll combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all the cinders have...

Страница 6: ...nally installed the first two boards on each side of the baffle support and pushed against the rear of the unit The stainless steel support hanger should be centered left to right between the sets of...

Страница 7: ...nsion reductions 2 51mm reduction for 2 51mm raised hearth USA and Canada 24 minimum hearth extension on all stoves as measured from the door opening of the unit 16 406mm minimumhearthextensiononallin...

Страница 8: ...min thickness of alternate material kM x thickness alternate k value per inch of listed material TM of listed material kL material TL TM inches kM x TL 84 TM inches 35 x 75 84 312 inches 417 x 75 Answ...

Страница 9: ...etails Note When installing your stove with a positive flue connection be sure to leave the insulation off the surround panels flanges and leave a 1 4 6 mm airspace insulation off the surround panels...

Страница 10: ...ive flue connection in masonry fireplaces is to secure a seal off plate i e 22 gage sheet steel in the fireplace throat using masonry screws Other acceptable methods include packing noncombustible mat...

Страница 11: ...on either side of the insert Install the side surround panels with the screws supplied Push the insert in until there is approximately a 1 4 6 mm gap between the back of the surround panels and the fa...

Страница 12: ...burn rate in the firebox For yourconvenience therodonthiscontrolismarkedwithfourgrooves to assist you in obtaining repeatable burn rates 3 Place a small amount of crumpled paper in front of the firebo...

Страница 13: ...e for a lower speed To turn off continue to rotate the knob counterclockwise until it clicks OFF Blower Speed Control Knob rheostat Manual Auto Rocker Switch TWO P SW MANUAL TE WHT NOTE SWITCH CONDITI...

Страница 14: ...Experiment with different loading configurations to achieve longer burns Try loading the wood from side to side and nesting it in the ashes to prevent airflow under and around the wood Fresh wood shou...

Страница 15: ...the fireboxalsokeeptheglassclean Nostovedoorstaysperfectlyclean The following are methods for keeping build up on your glass to a minimum When properly installed and operated by a knowledgeable operat...

Страница 16: ...KES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blankets are pushed back flush with the front of the baffle board...

Страница 17: ...embly DO NOT Close the door tightly during Burn In period DO Be sure to clean any fingerprints from the Gold or Nickel faceplate before burning the stove Clean the Gold or Nickel door only with a hous...

Страница 18: ...r Cord 19 H8069 UHPI Blower Cage Snap Switch Black H8070 UHPI Blower Cage Snap Switch Gold H8071 UHPI Blower Cage Snap Switch Nickel H8077 UHPI Blower Cage Snap Switch Brushed Gold H8078 UHPI Blower C...

Страница 19: ...acement Parts Model C310 33 34 36 36 37 37 46 47 48 35 40 40 38 38 38 41 38 38 38 38 38 38 38 38 38 38 39 39 39 39 42 44 42 43 38 38 43 40 40 41 38 38 38 45 19 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO S...

Страница 20: ...Replacement Parts Model C310 7 11 10 6 9 5 4 4 1 8 2 3 16 29 17 15 32 18 19 Blower Parts Door Parts 20 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE...

Страница 21: ...ck 33 x 48 71009 WFT2940 G Gold 29 x 40 71010 WFT2948 G Gold 29 x 48 71013 WFT3340 G Gold 33 x 40 71014 WFT3348 G Gold 33 x 48 71076 WFT2940 N Nickel 29 x 40 71077 WFT2948 N Nickel 29 x 48 71080 WFT33...

Страница 22: ...SAFETY LISTING LABEL 22...

Страница 23: ...23 NOTES...

Страница 24: ...t Use only parts sup plied from the manufacturer Normally all parts should be ordered through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When orderin...

Отзывы: