Blower Operation

The  blower  can  be  operated  manually  or  automatically  (blower  will 

turn on when the insert is hot and turn off when the insert is cool).  

The rocker switch on the control panel allows you to select between 

manual operation or automatic operation as follows (see 

Figure 10):

 

MANUAL OPERATION:  Turn rocker switch to the manual position (up) 

and adjust rheostat knob to the desired speed. The blower will have to 

be manually turned “OFF” by rotating the rheostat knob counterclock-

wise until it clicks.

AUTO  OPERATION:  Turn  rocker  switch  to  the  “AUTO”  position  and 

the rheostat to the ON position (rotate rheostat knob clockwise until it 

clicks). When the insert warms up, the blower will automatically turn 

on (adjust rheostat knob to the desired speed setting). When the insert 

cools down, the blower will automatically turn off.

Rheostat Operation -  The highest blower speed is obtained by turning 

the rheostat knob clockwise until it clicks “ON”, then rotate towards 

“HIGH” to increase blower speed.  Rotate the knob clockwise for a 

lower speed.  To turn off, continue to rotate the knob counterclockwise 

until it clicks “OFF.”

Figure 9 - Wiring Schematic

Figure 10 - Blower Controls

Blower Speed Control 

Knob (rheostat)

Manual / Auto

Rocker Switch

ROOM AIR

BLOWER

SPEED

CONTROL/OFF

TWO POSITION

SWITCH

MANUAL/TEMPERATURE

AUTO-RESET

TEMPERATURE

SWITCH N/O

POWER CORD

RED

RED

RED

YLW

BLK

WHT

GRN

NOTE: SWITCH CONDITIONS
GIVEN AT ROOM TEMPERATURE

N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN

         = FEMALE DISCONNECT
         = MALE DISCONNECT
         = STUD CONNECTION

Blower Operation Guidelines

While in auto operation mode, the blower will turn off and on based on the 

temperature of the stove.  Auto operation ensures there is sufficient heat 

build-up to warm the air being moved by the blower before the blower is 

turned on.  Likewise, when the stove cools off, the blower is turned off 

to prevent circulating cool air. Depending on the size and intensity of the 

fire it may be necessary to adjust the fan speed accordingly to ensure un-

interrupted fan operation. For example a small fire may require a slower 

fan speed to keep the heat output by the fan consistent.  If the blower is 

operated in manual mode, it may be necessary to adjust the blower speed 

as the fire begins to burn down and the stove is no longer hot enough to 

effectively heat the air moved by the blower.  If the air coming from the 

blower feels cool, one should either decrease the blower speed or stoke 

the fire to build up more heat.