Specifications and clearances are subject to change without notice.  

Refer to Installation Manual before installation of these appliances for 

updated dimensions and instructions.

10-1/2”

(267mm)

7"

(178)

5-1/8”

(130 mm)

12-1/8”

(308 mm)

3"

(76 mm)

1"

(25.4 mm)

Adapter SV4.5RCH

Square Horizontal Termination (SV4.5HT-2)

 

6 to 48 inch Vent 

Section, Telescopic 

vent section, Elbow or 

Appliance Collar

See Page 1  for Min. 

Distance to Base of Appliance.

Note: Center line of 

Vent Piping is NOT 

the Same as the 

Center line of the 

Framed Opening.

Firestop / spacer (SV4.5HF) shown on the exterior side 

of the wall. It may also be installed on the interior side.

* Ceiling Firestop/ 

Spacer (SV4.5VF)

Vertical 

Termination Cap 

SV4.5CGV-1 

(rated for high 

winds and freez-

ing conditions)

Ceiling Framing

10-1/2 in.

(267 mm)

10-1/2 in.

(267 mm)

Typical 

Installation

Venting 

Requir

ements

Minimum Clearances 

Inches (millimeters)

Back

1/2 (13)  - 0 (0) Spacers

Sides

1/2 (13) - 0 (0) Spacers**

Top Spacers

0 (0)

Floor

0 (0)***

Bottom of Appliance 

To Ceiling

64 (1626)

Vent

3 (76) Top * - 1 (25.4) 

Sides & Bottom

Service Clearances -Feet (meters)

Front

3 ft. (0.9 m)

Clear

anc

es

Shelf Height

Listing Information

US

 

Input (BTU) - Millivolt Models

Natural (NG) & Propane (LP) Gas

Models

Fuel

Input Rate (BTU / HR)

Adagio-MN

NG

13,000 (10,000 Low)

Adagio-MP

LP

13,000 (10,000 Low)

ADAGIO™-MN / ADAGIO-MP / ADAGIO-EN

 

Input (BTU) - Electronic Models

Natural (NG) & Propane (LP) Gas

Models

Fuel

Input Rate (BTU / HR)

Adagio-EN

NG

13,000 (10,000 Low)

Adagio-EP

if field converted

LP

13,000 (10,000 Low)

Tested to ANSI Z21.88 (in 
Canada, CSA-2.33), and 
CAN/CGA-2.17-M91 in both 
USA and Canada, as vented 
gas fireplace heaters.

Models

Combustible Shelf Height - Inches (millimeters)

Top Vent - with One 90 Degree Elbow

Adagio-MN

Adagio-MP

Adagio-EN

Secure Vent

Secure Flex (flex elbow)

*52 (1321)

*53-3/4 (1365)

* Includes 4” clearance to combustibles (required above vent components)

Side Wall Clearances (top view)

*  Note:

  3 in. (75 mm) above any horizontal vent component, except for installations which have and elbow connected to fireplace collar and that ends 

in a horizontal termination (this installation requires a 4” clearance above vent).

**  Note:

  See Installation Instructions Manual on 

Page 6 (Step 1)

 for clearance requirements to the nailing flange located at each side of the unit and 

any screw heads adjacent to it.

***Note

: To ensure proper fit of the facade, the appliance base will need to be elevated 3/4" above the floor to allow for the proper fit of the facade (i.e. 

Use 3/4" board as platform).

Do not insulate the

space between the

appliance and the

area above it.

*Shelf Height

(see table)

Shelf Above Fireplace - Top Vent

Drywall

Header

Top Spacers

4” 

 

(102mm)

u

 4" clearance is 

required above the 

elbow for installations 

that require an elbow at 

the top of the unit and 

that ends in a horizontal 

termination.

17"

(432)

14" (356)

Min. Distance to 

Unprotected Side Wall

45

°

Combustible Materials Allowed

In Shaded Area “Safe Zone”

2” (51) Minimum

Clearance to Combustibles

12" (305)

5"

(127)

Min. Distance

8-1/4” (210) to 

Protected Side Wall

Top View Of

Fireplace

Side

Wall

Side

Wall

inches (millimeters)

12 (305) Mantel

10 (254) Mantel

8 (203) Mantel

6 (152) Mantel

4 (102) Mantel

16

(406)

12

(305)

10

(254)

2 (51) Mantel

Top Of

Appliance

6

(152)

8

(203)

Mantel Clearances

Inches (mm)

14

(356)

Report No. 116-F-48-5

Printed in U.S.A. © 2007 Lennox Hearth Products

P/N  775,617M  REV. A  06/2008 