ADAGIO™-MN / ADAGIO-MP / ADAGIO-EN
Page 1 of 2
P/N 775,617M, REV. A, 06/2008
Fir
eplac
e D
imensions
Fr
aming D
imensions
Framing Dimensions - All Models
A
B
C
D
in.
22-1/8
40-1/4
15-3/4
44-1/8
mm
562
1022
400
1121
Corner Framing Dimensions - All Models
A
B
C
D
E
in.
22-1/8
41-5/8
29-1/2
10
20-7/8
mm
562
1057
749
254
530
Corner Framing With
SV4.5HT-2 Termination
Top Vent With Horizontal Termination In A Corner
Updated Drawings
(done) 1-16-07
Appliance Specifications - Adagio Series Direct Vent Fireplace Heaters
Notes
Due to Lennox' ongoing commitment to quality, all specifications, ratings and
dimensions are subject to change without notice.
** With the facade installed (required - sold separately), the appliance base
will need to be elevated a minimum of 3/4" above the floor to allow for the
proper fit of the facade (i.e. use 3/4" board minimum as platform).
Fireplace Dimensions - Inches (millimeters)
TM
Co-axial DV Vent
4-1/2" (114) Inner
7-1/2" (191) Outer
36-23/32
(933)
21-1/16 (535)
1-7/8
(48)
6-1/16
(154)
8-7/32
(209)
1-1/2
(38)
15-1/32
(382)
15-15/32
(393)
7-11/16
(195)
34
(864)
40-1/32
(1017)
20-3/4
(527)
14-3/4 (375)
5-13/32
(137)
Facade (Required) *
(arched style shown)
26-3/4” (680)
38-1/2”
(978)
20-1/4”
(514)
14-13/16” (376)
1/2”
(13)
1/2” (13mm) -
1-1/2” (38mm)
23-1/2” (597)
14-3/4”
(375)
20-3/4”
(527)
Facade (Required) *
(gated style shown)
1/2”
(13)
37-7/8”
(962)
18-3/4
(476)
1/2” (13mm) -
1-1/2” (38mm)
* A filigree inset kit is
also required (sold
separately). See Care
and Operation Manual
for ordering informa-
tion.
Facades
Cat. #
Model
Description
H5773
ADAGIO-AG
Arch Black
H5774
ADAGIO-PF
Arch Br. Nickel
H5775
ADAGIO-IG
Iron Gates
H5776
ADAGIO-CPD Copper Gates
Arch Facades*
Black & Brushed
Nickel Finishes
Gated Facades
Copper and Iron Gates
u
When installing in a corner configuration, one of
the rear stand-offs will need to be removed.
Inches
(millimeters)
C
Back wall of chase/enclosure
(including any finishing materials)
E
D
A
B
7 (178)
�
Facade
Facade
D*
B
VENT FRAMING -
TOP VENT WITH ONE
90
°
ELBOW
Framing should be
constructed of 2x4
or larger lumber
2 x 4 Header must be
installed, vertical as shown
to allow proper clearance
from venting components to
combustible header. See
Figure 50
for more
details.
A
C
Platform
**
Inches (mm)
8
(203)
5-1/8
13-1/8
(333)
10-1/2
(267)
(130)
3/4” Minimum from
Finished Floor