background image

ADAGIO™-MN / ADAGIO-MP / ADAGIO-EN

Page 1 of 2

P/N  775,617M,  REV. A, 06/2008

Fir

eplac

e D

imensions

Fr

aming D

imensions

Framing Dimensions - All Models

A

B

C

D

in.

22-1/8

40-1/4

15-3/4

44-1/8

mm

562

1022

400

1121

Corner Framing Dimensions - All Models

A

B

C

D

E

in.

22-1/8

41-5/8

29-1/2

10

20-7/8

mm

562

1057

749

254

530

Corner Framing With

SV4.5HT-2 Termination

Top Vent With Horizontal Termination In A Corner

Updated Drawings 

(done) 1-16-07

Appliance Specifications  - Adagio Series Direct Vent Fireplace Heaters

Notes

Due to Lennox' ongoing commitment to quality, all specifications, ratings and 

dimensions are subject to change without notice.
** With the facade installed (required - sold separately), the appliance base 

will need to be elevated a minimum of 3/4" above the floor to allow for the 

proper fit of the facade (i.e. use 3/4" board minimum as platform).

Fireplace Dimensions - Inches (millimeters)

TM

Co-axial DV Vent

4-1/2" (114) Inner 

7-1/2" (191) Outer

36-23/32

(933)

21-1/16 (535)

1-7/8

(48)

6-1/16

(154)

8-7/32

(209)

1-1/2

(38)

15-1/32

(382)

15-15/32

(393)

7-11/16

(195)

34

(864)

40-1/32

(1017)

20-3/4

(527)

14-3/4 (375)

5-13/32

(137)

Facade (Required) *

(arched style shown)

26-3/4” (680)

38-1/2”

(978)

20-1/4”

(514)

14-13/16” (376)

1/2”

(13)

1/2” (13mm) - 

1-1/2” (38mm)

23-1/2” (597)

14-3/4”

(375)

20-3/4”

(527)

Facade (Required) *

(gated style shown)

1/2”

(13)

37-7/8”

(962)

18-3/4

(476)

1/2” (13mm) - 

1-1/2” (38mm)

*  A  filigree  inset  kit  is 

also  required  (sold 

separately).  See Care 

and Operation Manual 

for  ordering  informa-

tion.

Facades

Cat. #

Model

Description

H5773

ADAGIO-AG

Arch Black

H5774

ADAGIO-PF

Arch Br. Nickel

H5775

ADAGIO-IG

Iron Gates

H5776

ADAGIO-CPD Copper Gates

Arch Facades*

Black & Brushed

Nickel Finishes

Gated Facades

Copper and Iron Gates

u

When installing in a corner configuration, one of 

the rear stand-offs will need to be removed.

Inches

(millimeters)

C

Back wall of chase/enclosure

(including any finishing materials)

E

D

A

B

7 (178)

Facade

Facade

D*

B

VENT FRAMING - 

TOP VENT WITH ONE
90

°

 ELBOW

Framing should be

constructed of  2x4

or larger lumber

2 x 4 Header must be 

installed, vertical as shown 

to allow proper clearance 

from venting components to 

combustible header. See 

Figure 50

 for more 

details.

A

C

Platform

**

Inches (mm)

8

(203)

5-1/8

13-1/8

(333)

10-1/2

(267)

(130)

3/4” Minimum from 

Finished Floor

Отзывы: