NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

17

Horizontal terminations have been designed to perform in a wide range of weather
conditions.  Our terminations meet or exceed industry standards.

When selecting the locations of your horizontal terminations, do not place the
termination where water from eaves and adjoining rooflines may create a heavy flow
of cascading water onto the termination cap.  If the cap must be placed where the
possibility of cascading water exists, it is the responsibility of the builder to direct the
water away from the termination cap by using gutters or other means.

Take care to carefully follow the installation instructions for the termination, including
the use of silicone caulking where required.

Figure 27

Figure 28

Installing the Square Horizontal Termination (SV4.5HT-2)

O. Install the desired termination -

1. Install the square termination (SV4.5HT-2)-
For the last step , from outside the exterior wall,
slide the collars of the termination onto the
adapter (the outer over the outer and the inner
inside the inner) until the termination seats against
the exterior wall surface to which it will be
attached.  Orient the housing of the termination
with the arrow pointed upwards.  Secure the
termination to the exterior wall.  The horizontal
termination must not be recessed into the
exterior wall or siding
 by more than the 1-1/4"
(32 mm) as shown in 

Figure 28.

SVHRK Snorkel Cap  –The snorkel cap is de-
signed to be fitted into a basement window box.
The SVHRK cap is for use with flex vent.  The
vertical distance between the inlet and outlet of
the cap is 28 in. (711 mm). pipe.

If the terminus of the last section is not within
this distance, use the telescopic vent section
SV4.5LA,  
as the last vent section. For wall
thicknesses greater than that shown in 

Figure

28, refer to Table 3 on page 18. This table lists
the additional venting components needed (in
addition to the termination and adapter) for a
particular range of wall thicknesses.

M.  Attach termination adapter - Attach the
adapter (SV4.5RCH - provided with the  termi-
nation) to the vent section or telescoping vent
section), elbow as shown in 

Figure 27  in the

same manner as any SV4.5 vent component
(refer to Step F).

N. Install Firestop/Spacer at exterior wall -
When using the square termination, install
the SV4.5HF (Secure Vent) or SF4.5HF (Se-
cure Flex) Firestop/Spacer over the open-
ing at the exterior side of the framing (long
side up) as shown in 

Figure 27, and fasten

into place.  Ensure 5" clearance is main-
tained by framing above the vent run for
MPLDV35/40/45 when center line of the
run is lower  than 48" (12119 mm) above
the fireplace top wrapper surface.

(The Firestop/Spacer may also be installed
over the opening at the interior side of the
framing.)

IMPORTANT:  The vent termination is
hot while in operation and for a period of
time following use of the fireplace.  To
prevent contact with hot surfaces, we
recommend the use of a Termination
Guard.  This can be purchased at your
local dealer.

Firestop/Spacer provided with the
termination shown on the exterior

side of the wall. It may also be

installed on the interior side.

SV4.5 HT-2

Termination

**7"

(178)

5-1/8"

(130 mm)

**12-1/8"

(308 mm)

Note: Centerline of Vent Piping is

NOT the Same as the Centerline of

the Frame Opening.

6 to 48 inch

Vent Section,

Telescopic vent

section on Elbow

See Figure 9 on page 8

for Min. Distance to Base

of Appliance.

Base of Appliance

**3” (76 mm)

for MPLDV30/35

1"

(25.4 mm)

Adapter

SV4.5RCH

10-1/2"

(267 mm)

**

Increase these dimensions by 2” (51mm) for MPLDV35/40/45
with horizontal vent runs with center lines lower than 48”

(1219mm) above the fireplace for wrapper surface.

Siding

Stucco

1-1/4" Maximum Recess of
Square Termination into
Exterior Finishing Material

Exterior Surface of

Framing

6 in. to 9-1/4 in.

(152 to 235 mm)**

Exterior Surface of Siding

Interior Surface of

Finished Wall

Maximum  wall thickness

10 in.(254 mm)**

SV4.5HT-2

Square Termination

Maximum Extent of

Vent Run Sections

Relative to Exterior

Surface of Framing

Last Vent Section. Use

T e l e s c o p i c   V e n t

Section (SV4.5LA), If

Necessary

Adapter

SV4.5RCH

SV4.5HT-2

Square Termination

Venting Connection and Exterior Wall Recessing of the

Horizontal Square Termination (SV4.5HT-2).

*Use silicone caulking to
seal the top and sides of
the termination, up to the
underlayment, stucco, or
masonry wall surface.

**For thicknesses greater
    than 10”, see Table 3.

*Caulk

*Caulk

Содержание 2-EN53-VDLPM

Страница 1: ...se trouvant dans le batiment o vous vous trouvez Evacuez la pi ce le b timent ou la zone Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous...

Страница 2: ...the bottom compartment 4 One vent restrictor to be used as detailed on page 10 5 One hood and one control compartment cover and one 45 degree starter elbow are strapped to the top of the unit GENERAL...

Страница 3: ...ove 4500 ft For elevations above 4500 feet 1372 meters install the unit according to the regulations of the local authorities having jurisdictionand intheUSA thelatestedition of the National Fuel Gas...

Страница 4: ...m m 6 2 6 1 n i 4 6 T N E V m m 4 5 2 n i 1 S E C N A R A E L C E C I V R E S T N O R F s r e t e m 9 0 t e e F 3 Shelf Height see table Do not insulate the space between the appliance and the area ab...

Страница 5: ...nwealth of Massachusetts hori zontal terminations installed less than seven 7 feet above the finished grade must comply with the following additional requirements A hard wired carbon monoxide detector...

Страница 6: ...onic Appliances Connect 120 Vac electrical power to the appliance receptacle Step 5 page 22 Make connection to gas supply Step 6 page 23 Install the logs and glow ing embers Step7 page23 Checkoutappli...

Страница 7: ...o t a l u g e r r e t e m t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b a t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e...

Страница 8: ...lations the horizontal vent length a to b must not exceed 28 inches 711 mm Inches millimeters These dimensions occur when one 45 degree elbow is connected directly to the appliance collar Back wall of...

Страница 9: ...1 3 5 9 4 3 5 3 1 6 8 6 7 2 0 5 1 5 2 2 9 6 5 3 V D L P M n i 2 1 0 4 2 1 7 3 8 5 0 2 8 1 9 2 4 1 5 3 4 3 4 2 8 3 2 1 4 1 7 2 m m 9 2 0 1 3 5 9 4 3 5 0 4 7 5 9 8 9 2 6 4 1 3 2 9 6 0 4 V D L P M n i 2...

Страница 10: ...SYSTEMS ROOF Figures 13 17 and 23 through 25 on pages 12 14 and 15 and their associated Vertical Vent Tables illustrate the various vertical vent ing configurations that are possible for use with the...

Страница 11: ...6 6 8 1 5 5 1 0 0 0 0 4 4 5 0 9 1 5 7 8 5 1 1 0 0 0 4 5 5 6 9 1 5 7 3 6 1 0 1 0 0 4 5 5 5 0 2 5 2 1 7 1 0 1 1 5 0 7 7 0 2 5 2 7 1 0 0 0 6 0 6 5 1 1 2 5 2 6 7 1 1 0 0 6 0 7 5 7 1 2 5 2 1 8 1 0 1 0 6 0...

Страница 12: ...r to Figure 15 Push the vent component against the starter elbow until it fully engages then twist the component clockwise running the dimples down and along the incline channels until they seat at th...

Страница 13: ...5 and SV4 5E90 elbows in the same manner as the straight vent sections The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with...

Страница 14: ...10 15 4 572 3 0 914 20 6 096 4 1 219 V H 40 feet 12 2 m Max H 20 feet 6 096 meters Max meters 40 feet 12 2 meters Maximum Ceiling Firestop Spacer SV4 5VF When using Secure Flex use Firestop Spacer SF4...

Страница 15: ...es covered in this document are fittedwithcollarshavinglockinginclinedchan nels The dimpled end of the vent components fit over the appliance collar to create the posi tive twist lock connection C Pla...

Страница 16: ...ot run ratios that are smallerareacceptableallthewaydowntoator near level Use a carpenter s level to measure fromaconstantsurfaceandadjustthesupport straps as necessary It is important to maintain the...

Страница 17: ...coping vent section elbow as shown in Figure 27 in the same manner as any SV4 5 vent component refer to Step F N Install Firestop Spacer at exterior wall When using the square termination install the...

Страница 18: ...c s e l e T d n a t i K n o i t a n i m r e T n i 2 1 7 o t 2 A L 5 4 V S n o i t c e S 6 L 5 4 V S n o i t c e s t n e v n i 6 2 0 5 o t 9 7 2 4 3 9 1 o t 1 1 Note SV4 5VF Secure Vent SF4 5VF Secure...

Страница 19: ...p Spacer SV4 5HF or SF4 5HF when using Secure Vent or Secure Flex respectively Use Firestop Spacer SV4 5HF5 or SF4 5HF5 when using Secure Vent or Secure Flex on horizontal vent runs for the MPLDV35 40...

Страница 20: ...rapper surface In all cases the firestop spacer provided with the termination may be used with the termination frame to 5 clearance where applicable HORIZONTAL VENT FIGURES TABLES CONTINUED Figure 33...

Страница 21: ...ex Pipe 1 Installthesmall gearclamplooselyaroundthe innerflexibleventpipe pushitbackoutoftheway 2 Apply a bead of Mill Pac Black 700 F high temperature sealant Catalog No 10K81 to the inner adapter co...

Страница 22: ...the appliance junction box 2 Remove the electrical inlet cover plate from the side of the unit by removing the plate s securing screws See Figure 11 on page 9 3 Removethe coverplate sknockoutandthen f...

Страница 23: ...rd pipe and tighten with wrenches from above through the firebox opening If required access the valve by removing the lower control compartment panel see Figure 39 by lifting and pulling the panel for...

Страница 24: ...4 as shown in Figure 39 Refer to Figure 43 and loosen the set screw for the venturi air shutter Manually actuate the air shutter through several cycles Set the air shutter to 3 32 before placing the...

Страница 25: ...R SHUTTER MOVES WHEN THE LEVER ARM IS OPERATED Note When first operating the air shutter adjustment lever arm observe the air shutter If it is not moving open the glass ensure the air shutter screw is...

Страница 26: ...8 203 MANTEL 6 152 MANTEL 4 102 MANTEL 18 457 14 356 12 305 2 51 MANTEL TOP OF APPLIANCE 8 203 10 254 MANTEL CLEARANCES Inches mm 16 406 Figure 45 COLD CLIMATE INSULATION For cold climate installatio...

Страница 27: ...S x e l F f o m m 4 1 9 n i 6 3 x e l F d e s s e r p m o c 8 0 L 4 9 S S 8 4 T I K F S h t i w m r e T e r a u q S l l a m S x e l F f o m m 9 1 2 1 n i 8 4 x e l F d e s s e r p m o c o N t a C o N...

Страница 28: ...ONFORM MENTAUXINSTRUCTIONSDUFABRICANTET TOUTES EXIGENCES ET CODES APPLICABLES DE L AUTORIS SAVOIRLAJURIDICTION SIL INFORMATION DANS CETTE INSTRUCTION N EST PAS SUIVIE EXACTEMENT UN FEU EXPLOSION OU PR...

Страница 29: ...ns do not use pipe joint compounds on flare fittings Step 10 Attach the conversion label provided in the conversion kit to the rating plate on the appliance Step 11 Turn on gas supply and test for gas...

Страница 30: ...30 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 31: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 31 NOTE THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 32: ...0 043M REV F 09 2008 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products C...

Отзывы: