background image

MAINTENANCE 

 

PAGE 18 

CREOSOTE FORMATION AND NEED FOR REMOVAL 
What is Creosote -

 When wood is burned slowly, it pro-

duces tar and other organic vapors, which combine with 
expelled moisture to form creosote. The creosote vapors 
condense in the relatively cool chimney flue of a slow-
burning fire. As a result, creosote residue accumulates 
on the flue lining. When ignited this creosote makes an 
extremely hot fire. Also, creosote deposits tend to form in 
long runs of venting where gases become too cool prior 
to exhausting. Note: Single wall pipe cools rapidly, there-
fore installations using this type of flue are more suscep-
tible to creosote deposits. 
 
To inhibit the build up of creosote, adjust the primary air 
control to a medium-high or high setting for a 10-minute 
period each day.  Do not attempt to burn out heavy creo-
sote accumulations in this manner.  This must be re-
moved from the chimney by scraping or brushing to re-
duce the risk of a chimney fire. 
 

Burn Approved Fuel Only

 - This stove is approved for 

burning dry seasoned natural wood only.  Using green or 
inadequately seasoned wood may increase creosote 
buildup. 
 

Inspection Frequency -

 The chimney connector and 

chimney should be inspected at least twice monthly dur-
ing the heating season to determine if a creosote buildup 
has occurred. If creosote has accumulated it should be 
removed to reduce the risk of a chimney fire. 
 

Cleaning -

 Remove the baffle plates in the firebox prior 

to having your chimney cleaned (should be done by a 
qualified chimney sweep). See following – 

Removing 

Baffle Plates for Cleaning

). 

 

Removing Baffle Plates for Cleaning

 

Note: The smoke baffle in the upper firebox area consists 
of two heavy gage steel plates. One of these plates has 
a welded strap to overlap the seam, which runs front to 
back between the two. Before removing the baffle plates 
from the firebox, wearing a pair of leather or work gloves 
is recommended. 

1.  To remove the baffle, reach inside the firebox and 

slide one plate over the other. 

 
2.  Next move the metal plates, stacked one on top of 

the other, sideways toward the center of the stove.  

 
3.  Then move the two baffle plate toward the front of 

the stove to clear the ledge they rest on at the rear. 
Be mindful these metal plates are quite heavy, so 
use care in lowering them out of the way

.

 

 
4.  Once the baffle plates are out of the firebox, the flue 

can be cleaned. The accumulated soot that is re-
moved by brushing will fall to the firebox floor where 
it can be removed and disposed of. 

 

WARNING!  DO NOT OPERATE THE STOVE WITH-
OUT THESE BAFFLE PLATES PROPERLY IN-
STALLED.  THIS WILL VOID WARRANTY.

 

 

In the event of a chimney fire - 

Make sure the fuel door 

is securely closed. Adjust the primary air control to the 
lowest (most closed) setting.  Call the fire department 
immediately. After a chimney fire, the complete chimney 
system should be checked by a qualified technician be-
fore further use. 
 
Consult your dealer for suggestions on proper chimney 
care. Contact your local municipal or provincial fire au-
thority for information on how to handle a chimney fire. 
Have a clearly understood plan for handling a chimney 
fire. 

 
REINSTALL BAFFLE PLATES

 

After your chimney has been swept, reinstall the baffle 
plates. See – 

Removing Baffle Plates for Cleaning

 (on 

this page) and reverse steps. 
 

CLEANING BLOWER INTAKE 

If an optional blower kit (catalog #14M22) is installed, the 
blower air intake requires cleaning at least once a year to 
remove lint, dust, etc. If there are pets in the dwelling, the 
intake should be cleaned at least twice a year.

 

Содержание 1900HT-M

Страница 1: ...NUAL RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE EPA CERTIFIED WOOD BURNING STOVE THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER READ ENTIRE MANUAL THOROUGHLY BEFORE INSTALLATION P N 775002M Rev F 11 03 MODEL 1900HT M ...

Страница 2: ...se gasoline gasoline type lantern fuel kerosene charcoal lighter fluid or similar liq uids to start or freshen up a fire in this heater Keep all such liquids well away from the heater while it is in use 10 DO NOT OVERFIRE If heater or chimney con nector glows you are overfiring Overfiring this appliance could cause a house fire Overfiring is a condition where the appliance is operated at temperatu...

Страница 3: ...and ash lip One Insulation pad and strips Place pad and strips under top marble USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention to the safety instructions provided in this manual The Homeowner s Care and Operation Instructions included here will assure you have many years of dependable and enjoyable service from your appl...

Страница 4: ...2 1 WARNING ELECTRICAL GROUNDING INSTRUC TIONS THIS APPLIANCE IS EQUIPPED WITH A THREE PRONG GROUNDING PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROP ERLY GROUNDED THREE PRONG RECEPTACLE DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLI ANCE 2 Local amendments 3 Is a permit required cost You may wish...

Страница 5: ...ity to Combustibles Electrical Wiring The installation of this stove will require some research Once your options are determined consult with your local building department who will be able to give you the necessary installation requirements for your area Is a building permit required Rooms where installation may not be allowed etc WARNING CHECK ALL LOCAL BUILDING AND SAFETY CODES BEFORE INSTALLAT...

Страница 6: ...not permit ted Chimney must be Simpson Dura Vent Dura Plus chimney with manufactured mobile home installation kit Dura Vent part number 6DP MH Chimney connec tor between stove and chimney must be Simpson Dura Vent DVL close clearance connector pipe Manufac tured Mobile Home installations must use a rain cap with a spark arrester Clearances Inches A 13 6 C 15 E 15 B 25 D 6 F 5 PROTECTED WALL CLEARA...

Страница 7: ...The following 2 optional kits are required to deliver out side air to this appliance Contact your dealer to order Catalog 14M67 Outside Air Floor Duct Catalog 14M68 Back Cover Plate In all manufactured mobile homes and in many site built residences subject to local code a stove may be required to use outside air for combustion A 5 square outside air floor duct Back Cover Plate is available through...

Страница 8: ...for shipping with a small retaining screw at the top of drawer Remove and dis card this screw BAFFLE PLATES This appliance has two heavy steel baffle plates that are installed in the upper firebox over the steel secon dary air supply tubes During shipment and installa tion the baffle plates might slide around and may need to be repositioned lined up to each other and pushed to the back wall in ord...

Страница 9: ...per the Vent Manufactur ers installation instructions Ensure that there is an ef fective vapor barrier at the location where the chimney penetrates to the exterior of the structure This can be accomplished by applying a non hardening waterproof sealant to the following components Around the chimney at the point where the storm collar will meet the chimney just above the Flash ing Along the vertica...

Страница 10: ...ion air to the fire chamber and for safely removing unwanted combustion byproducts from the appliance If the venting system s design does not pro mote these ends the system may not function properly Poorly functioning venting systems may create per formance problems as well as be a safety hazard i e an oversized chimney may result in less than optimum performance Installations into a large masonry...

Страница 11: ...Using 6 Diameter Single Wall Connector Pipe Not Approved For Manufactured Mobile Homes MANUFACTURED MOBILE HOME STAN DARD Using 6 Diameter Type L Vent Connector Pipe MANUFACTURED MOBILE HOME STANDARD Using 6 Diameter Type L Vent Connector Pipe ...

Страница 12: ...ide wall of the Solid Pak chimney The inner end of the Solid Pak chimney section shall be flush with the inside of the masonry chimney flue and sealed with a non water soluble refractory cement Use this cement to also seal to the brick masonry penetration Method C 6 inch 152mm Clearance to Combustible Wall Mem ber Starting with a minimum 24 gage 024 inch 61 mm 6 inch metal chimney connector and a ...

Страница 13: ... with 24 karat industrial grade gold and requires curing to harden the gold Once it is cured it will never tarnish Prior to burning this appliance the doorframe should be cleaned thoroughly with a good window cleaning solution and a soft cloth Do not use any metal polishes or abrasives to clean the gold sur face Any oils or fingerprints left on the gold could be come permanent blemishes if the sto...

Страница 14: ...e high burn control plate so it is not left open Generally you will want to set the air control somewhere in the low or medium range Low Burn approx 9 000 13 000 Btu hr Pull control handle out approx 3 4 Medium Burn approx 13 000 16 000 Btu hr Pull control handle out approx 1 1 2 Medium High Burn approx 16 000 25 000 Btu hr Pull control handle out approx 2 1 2 until small click is felt High Burn M...

Страница 15: ...t is available at your local authorized Len nox Hearth Products dealer Never attempt to paint a hot stove FIRST FIRE When your installation has been completed and in spected you are ready to build your first fire 1 Pull the primary air control to the full open position located below the ash lip 2 Open door and build a small fire in the stove using paper and dry kindling Wait a few minutes for a go...

Страница 16: ...od only see Important Warnings page 2 No 8 Do not burn particleboard scraps or pressed logs using bonding agents because they can produce conditions which will deteriorate metal Green or uncured wood does not work well as fuel and can cause increased creosote buildups The value of green wood as a source of heat is limited Do not overload or use kindling wood or mill ends as primary fuel as this ma...

Страница 17: ...gallons of ashes DOOR GLASS AND ASH DRAWER GASKETS A 3 4 spun fiberglass rope gasket provides the seal around the fuel door and a 1 8 x 1 flat woven gasket glass provides the seal around the glass And a 1 4 spun fiberglass gasket provides a seal around the ash drawer Should these gaskets become frayed or dam aged they should be replaced with the same size and type as the original gasket Contact yo...

Страница 18: ...ts of two heavy gage steel plates One of these plates has a welded strap to overlap the seam which runs front to back between the two Before removing the baffle plates from the firebox wearing a pair of leather or work gloves is recommended 1 To remove the baffle reach inside the firebox and slide one plate over the other 2 Next move the metal plates stacked one on top of the other sideways toward...

Страница 19: ...se a full length liner to achieve ade quate draft for the appliance A draft gauge should read a minimum of 05 w c inches water column not to exceed 07 w c for optimum performance See Draft Requirements on page 10 OVERFIRING DAMAGE If the heater or chimney connector glows you are overfir ing Other symptoms may include Cracking warping or burning out of components gold doors may turn color stove gla...

Страница 20: ...8 UNF Retrofit Requires Drill 3 213 Tap 10362 Torque Plate Latch Component Parts 1135 Knob Ash Drawer 27M80 Gasket Ash Drawer 1 2 X 1 8 x 16 907 Handle Air Control 26M19 Module Draft Control controls burn rate Includes gasket 14440 Dial A Temp rheostat MS1502 Marble Set Gray Also requires 1each 1054 4 each 1051 MS1505 Marble Set Green Also requires 1each 1054 4 each 1051 775002M Installation Opera...

Страница 21: ...B 2 2 9 x 4 1 2 w notch FB11 2 4 1 2 x 4 1 2 FB 3 2 9 x 4 1 2 w hole FB23 2 5 x 1 FB7 4 9 x 2 1 8 37075 grate 2 4 1 2 x 4 3 8 PAGE 21 FIREBRICK DIAGRAM DOOR ASSEMBLY HANDLE ASSEMBLY MARBLESETS INSETSFORSTOVETOP ASHLIP Part Catalog MS1502 Gray Marble Set Part Catalog MS1505 Green Marble Set Marble is a natural product and therefore each piece will have its own unique character ...

Страница 22: ... utilizing this floor penetration duct Duct penetration measures 5 square Back Cover Plate BCP 19 See illustration above When using outside combustion air the back cover plate is required to seal off the primary combustion air intake so that it can no longer draw air from within the room Blower Kit BK 100 A Blower Kit includes rheostat for variable speed con trol is available for increased heat ci...

Страница 23: ...8 460 mm Fuel capacity 45 to 55 lbs 20 25 kg Firebox Size 2 cubic feet 610 mm Loading Front Width of outer top 27 3 4 705 mm Depth 27 1 2 699 mm stove back to ash lip front edge Height to flue 32 3 4 832 mm Height to stove top 33 1 2 851 mm Back to center line of flue 9 Approx weight with brick 380 lbs 173 kg Blower Optional 160 cfm Square feet heating capacity and burn time are approximations onl...

Страница 24: ...SAFETY LISTING LABEL PAGE 24 ...

Страница 25: ...EPA LABEL PAGE 25 ...

Страница 26: ...e 26 OWNERSHIP RECORDS Dealer s Name Dealer s Address City State Zip Code Serial Number Date of Purchase Date Installed Notes SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Description ...

Страница 27: ...1110 West Taft Avenue Orange CA 92865 ...

Отзывы: