• 9 •

Installation, Operation and Maintenance Manual / 

ARIA2-IOM-1910-E

WIRING DIAGRAM

WIRING DIAGRAM WITH ELECTRICAL HEATER

Fan speed control

 0-10 Vdc

2x0,5 sqmm 

twisted / shielded

Fan speed control
0-10 VDC - 2x0,5 sqmm twisted / shielded

LEGEND

PE

 . . . . . . . .  Protective conductor (Yellow/Green)

L

 . . . . . . . . .  Phase (Black)

N

 . . . . . . . . .  Neutral (Blue)

A1

 . . . . . . . .  Electronic control

M1

 . . . . . . . .  Fan motor

XA1

 . . . . . . .  Terminal board

LEGEND

PE

 . . . . . . . .  Protective conductor (Yellow/Green)

L

 . . . . . . . . .  Phase (Black)

N

 . . . . . . . . .  Neutral (Blue)

A1

 . . . . . . . .  Electronic control

M1

 . . . . . . . .  Fan motor

KA1

 . . . . . . .  Relay

R1

 . . . . . . . .  Electric heater

ST1

 . . . . . . .  Safety thermostat - automatic switch

ST2

 . . . . . . .  Safety thermostat - manual switch

XA1-2

 . . . . .  Terminal board

YV1-2

. . . . . .  Water valve actuator

Permanent power supply

230Vac/50Hz - 3x1 sqmm

Permanent power supply

230Vac/50Hz - 3x2,5 sqmm

Cool valve control (4 pipe system) 
ON/OFF - 230Vac/50Hz - 2x1 sqmm

    - or -

Heat/cool valve control (2 pipe system) 
ON/OFF - 230Vac/50Hz - 2x1 sqmm

Heat valve control (4 pipe 
system)
ON/OFF - 230Vac/50Hz - 2x1 mm²

Or

Electric heater control
ON/OFF - 230Vac/50H

Содержание ARIA 2

Страница 1: ...www lennoxemea com INSTALLATION OPERATING AND MAINTENANCE ARIA2 IOM 1910 E DUCTABLE FANCOIL ARIA 2 1 3 6 6 kW...

Страница 2: ...mets Spigot outside air intake Additional condensate drain pan Changing filters Plenum and suction to change the air flow Air curtain kit spigot removal Water connections Electrical connections Connec...

Страница 3: ...that mains voltage is potentially dangerous and that any device connected to it must be used care fully Before working on the appliance unplug it from the mains pull the power plug or isolating the s...

Страница 4: ...ce Manual ARIA2 IOM 1910 E GENERAL SIZE UNIT GENERAL SIZE UNIT NOMENCLATURE WATER CONNECTIONS RIGHT LEFT WATER CONNECTIONS SAFETY REQUIREMENTS Do not leave packages loose during transport Do not expos...

Страница 5: ...ACCESSORIES ACCESSORY 2 PIPES OCTAVE BAND Hz 4 PIPES ACOUSTIC ATTENUATION OPERATING LIMITS SUMMER COOLING Minimum temp Water inlet 4 C Maximum operating pressure 8 bar Maximum temp Ambient air 35 C Ma...

Страница 6: ...e no obstructions to the air passage on the suction and discharge 3 The water connections have position size and spacing as required by the device 4 The system pressure does not exceed 8 bar for the w...

Страница 7: ...stallation Operation and Maintenance Manual ARIA2 IOM 1910 E ADDITIONAL CONDENSATE DRAIN PAN AIR CURTAIN KIT SPIGOT REMOVAL CHANGING FILTERS PLENUM AND SUCTION TO CHANGE THE AIR FLOW Discharge plenum...

Страница 8: ...ine must be equipped with disconnect switch in compliance with European standard EN60947 3 Make sure the electrical system is capable of providing not only the working current required but also the cu...

Страница 9: ...ective conductor Yellow Green L Phase Black N Neutral Blue A1 Electronic control M1 Fan motor KA1 Relay R1 Electric heater ST1 Safety thermostat automatic switch ST2 Safety thermostat manual switch XA...

Страница 10: ...LEGEND PE Protective conductor Yellow Green L Phase Black N Neutral Blue A1 Electronic control M1 Fan motor XA1 Terminal board YV1 Cool water valve actuator YV2 Heat water valve actuator LEGEND PE Pro...

Страница 11: ...ipment and in particular the tightening of electrical connections Check the tightness of all the bolts nuts and whatever else can be loosened by the constant vibration of the unit Check that the motor...

Страница 12: ...0 LENNOX DISTRIBUTION 33 4 72 23 20 20 www lennoxemea com ARIA2 IOM 1910 E Due to LENNOX EMEA ongoing commitment to quality the specifications ratings and dimensions are subject to change without noti...

Отзывы: