DOC-1135-EN-US— revision 1.001

Connections

Maintenance

This unit is intended for use by Service Personnel only. There are NO USER 
SERVICEABLE parts inside.

There is no regular maintenance required of the LNL-200XAU other than 
periodic testing and replacement of the standby battery. Reference should be 
made to the battery manufacturer's documentation to determine typical/
expected battery life with a view to periodic replacement of the battery. 

Disposal of Product at End of Life

This product falls within the scope of EU Directives 2012/19/EU Waste 
Electrical and Electronic Equipment (WEEE) and 2013/56/EU (Battery). At 
the end of life, the product must be separated from the domestic waste 
stream and disposed via an appropriate approved WEEE disposal route in 
accordance with all national and local regulations.

Before disposal of the product, any batteries must be removed, and disposed 
separately via an appropriate approved battery disposal route in accordance 
with all national and local regulations. Package used batteries safely for 
onward transport to your supplier, collection point or disposal facility.

See Specifications for battery type information. The battery is marked with 
the crossed out wheelie bin symbol, which may include lettering to indicate 
cadmium (Cd), lead (Pb), or mercury (Hg). For more information, see 

www.recyclethis.info

.

Note:

Risk of fire or explosion if bare battery wires are allowed to 
touch.

Compliance

This power supply unit meets the essential requirements of the following 
European Directives:

Low Voltage 2014/35/EU

EMC 2014/30/EU 

WEEE 2012/19/EU

RoHs2 2011/65/EU

Explanation of Symbols

Not all may apply.

Product Warnings and Disclaimers

THESE PRODUCTS ARE INTENDED FOR SALE TO AND 
INSTALLATION BY QUALIFIED PROFESSIONALS. UTC FIRE & 
SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY 
PERSON OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY 
"AUTHORIZED DEALER" OR "AUTHORIZED RESELLER", IS 
PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL 
FIRE AND SECURITY RELATED PRODUCTS.

For more information on product warnings, refer to

https://www.firesecurityproducts.com/policy/product-warning/ 

or scan the 

following code:

PoE IN

PoE 802.3bt (60 W) from PoE++ source

Note:

 PoE and PoE+ can be used. See output 

specifications.

DATA

Data connection to IP device

OP +/-

Load output: 13.8 VDC (+/- 5%) at 3 A max 
(PoE++ input)

BATT +/-

12 V battery connection - observe polarity

PoE

Relay output for PoE power failure. Open on loss 
of PoE.

GEN

Relay output for output fuse failed or/and low 
battery level (less than 10.7 VDC) when PoE is off. 
Open in fault condition.

Fault indication

Mains present

Protective earth

Shock risk - Isolate before attempting access

Certification level

Do not dispose of in unsorted waste