Regulatory Information
80
DirecDoor Installation Guide
WEEE
European Union directive:
The European directive “Waste Electrical and Electronic Equipment” (WEEE) aims to minimize the
impact of electrical and electronic equipment waste on the environment and human health. For proper
treatment, recovery and recycling, you can return the equipment marked with this symbol to your
local supplier upon the purchase of equivalent new equipment, or dispose of it in designated
collection points. Further information can be found on the following website:
www.recyclethis.info
European representative for manufacture: UTC Fire & Security B.V., Kelvinstraat 7, 6003 DH Weert,
The Netherlands.
UL Compliance
Failure to install and program the DirecDoor access panel and OnGuard system in accordance with
these instructions voids the listing mark of Underwriters’ Laboratories, Inc.
A clearly marked redundant system with the same configuration as the primary machine must be
available as a backup.
The monitoring equipment must be protected by a Listed Transient Voltage Surge Suppressor with a
maximum rating of 330 V Listed under UL 1449. The communication circuit must be protected with
a Secondary Protector for Communication Circuits Listed under UL 497A.
The monitoring equipment must be installed in a temperature controlled environment with 24 hours
of standby power for the HVAC and computer system. In addition to the 24 hours of standby power, a
minimum of 15 minutes of standby power must be available to the computer system via a UPS
system. The UPS system must be Listed to UL 1778 or UL 1481 and must be provided with a
maintenance bypass switch.
•
Operating environment: 32°to 120° F (0° to 49°C); humidity range: 85%
•
PoE is not verified for UL installations.
•
Auxiliary power supplied must be an approved UL 294 power-limited supply, such as the
Altronix Corp. Model AL300ULM.
•
Connections to J5 (RS485), J7 (NX BUS), J9 (Console Port), and J8 (LOW BATT circuit) have
not been verified for UL installations.
Note:
The DDSDC does not support J5 (RS485) or J7 (NX BUS).
•
RDR 1 SDI/REX/RELAY (terminal block J2), RDR 2 SDI/REX/RELAY (terminal block J4),
and FACP INPUT (terminal block J6) terminals all need to be stated as being connected within
the protected area. These terminals include DC+, DC-, REX+, REX-, GND, RLYNC, COM, and
RLYNO since faults can cause unauthorized access.
Note:
The DDSDC supports only one door relay (J2).
Ratings
Door Strike rating
2 A @ 24 VDC, 2 A @ 30 VAC
Note:
Models T700, T720, and T725 with DirecDoor have not been evaluated by UL.
Содержание DirecDoor
Страница 1: ...7 4 DirecDoor Installation Guide...
Страница 4: ......
Страница 8: ...Table of Contents 8 DirecDoor Installation Guide...
Страница 14: ...Introduction 14 DirecDoor Installation Guide...
Страница 19: ...DirecDoor Installation Guide 19 Mounting DirecDoor Mounting Template...
Страница 22: ...Installation Planning and Mounting 22 DirecDoor Installation Guide...
Страница 56: ...DDIO Interface 56 DirecDoor Installation Guide Resistances Detected by PXNplus...
Страница 58: ...DO Interface 58 DirecDoor Installation Guide Wiring Output Device to DO Interface...
Страница 76: ...Controller Firmware Tools 76 DirecDoor Installation Guide...
Страница 79: ...DirecDoor Installation Guide 79 CE Regulatory Notice CE Regulatory Notice...
Страница 89: ...DirecDoor Installation Guide 89 Index...