background image

Maintenance Procedure 

Equipment should only be inspected and maintained by qualified trained personnel. These instructions 
are meant as a guide to what actions should take place; it is not an instruction on how to complete the 
activities. 

Maintenance should be performed monthly or more frequently if necessary. 

1. Inspect and clean if necessary all air vent openings.
2. Inspect and replace if necessary the AC power cord for exposed wires, torn or worn insulation,

or a broken cord retaining clamp.

3. Ensure that the two circuit breakers on the rear panel have not tripped.  If either one or both

circuit breakers have tripped, call Lencore customer service.

4. Ensure that all cables and wires are properly seated in their respective connectors.

6.2

 | 

Maintenance Procedure

33

Содержание Operating Platform

Страница 1: ...INSTALLATION OPERATIONS MANUAL OP RACK MOUNT...

Страница 2: ...rician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 1...

Страница 3: ...diagram table of contents section 3 INSTALLATION 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 10 section 5 OP Rack Mount Installation Instructions OP Rack Mount and Speaker Placement Hang Speakers Install O...

Страница 4: ...uid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Follow COMPLETE instructions for wiring...

Страница 5: ...einensuringpropercommunications in the event of an emergency You have been provided with state of the art equipment and technology to install test tune and finalize As such your goals for the complete...

Страница 6: ...n allow zone additions modifications deletions and other changes to the paging system on the fly without rewiring This eliminates the need for running multiple home runs back to the electrical closet...

Страница 7: ...ology FT Terminator The free topology terminator is used to change the topology of the network from a BUS to a free or flexible topology 06 Speakers Emerald Technology speakers are designed to be an i...

Страница 8: ...ges or other devices 2 2 optional accessories 11 Strobes Strobes are visual communication devices that alert occupants of an event A variety of different colored strobes are available and depending on...

Страница 9: ...red in order to generate enough power to make the message clear and intelligible 13 Mic Pre Amp Designed to offer superior paging the Microphone Pre Amplifier with Automatic Gain Control AGC is Lencor...

Страница 10: ...2 3 system flow diagram n FORM 5...

Страница 11: ...2 4 Example system speaker placement and wire diagram n FORM 6...

Страница 12: ...ROWN WHITE BROWN 1 2 3 4 5 6 7 8 AUDIO AUDIO SPEAKER SENSE AUDIO AUDIO SPEAKER SENSE AUDIO AUDIO speaker PINS 568 B Speaker Cable connections are from OP Rack Mount to Speakers and from Speaker to Spe...

Страница 13: ...DATA NETWORK LON B ILON DATA NETWORK INITIALIZATION SEQUENCER PAGE PAGE INITIALIZATION SEQUENCER MUSIC MUSIC data PINS 568 B Data Cable connections are from the Music Page Interface 6 MPI 6 to OP Rac...

Страница 14: ...8 AUDIO INPUT 4 AUDIO INPUT 4 AUDIO INPUT 1 AUDIO INPUT 3 AUDIO INPUT 3 AUDIO INPUT 1 AUDIO INPUT 2 AUDIO INPUT 2 audio PINS 568 B Audio Cable connections are from the Music Page Interface 6 MPI 6 to...

Страница 15: ...placing equipment Check wiring runs to properly estimate needed quantity of wire for the project Check quantity for Data Wire CAT 5e 4 pair Audio Wire CAT 5e 4 pair Speaker Wire CAT 5e 4 pair Check th...

Страница 16: ...ANY COMPUTER OR NETWORK EQUIPMENT OTHER THAN AN i LON OR ANOTHER OP RACK MOUNT INSTALLATION IMPORTANT Lencore suggests installing equipment in this sequence Hang speakers Install Rack Mount Run wire w...

Страница 17: ...wder action gun such as a Hilti gun or drill and screw check your local building codes for allowable hanging methods and standards Drive a nail holding the clip with the speaker chain and speaker into...

Страница 18: ...field Check and install each respective OP Rack Mount according to the drawing OP Rack Mounts are installed in a standard 19 rack 3 4 install op rack mount IMPORTANT leave 1RU space above each OP for...

Страница 19: ...AE Router needed at that point to extend distance IMPORTANT Double check for long home runs and runs between floors as these will require much longer lengths of wire Check wiring schematics for your...

Страница 20: ...and Audio IN jack of the second OP Rack Mount Continue connection from OP Rack Mount to OP Rack Mount in numbered sequence You may NOT skip a sequenced OP Rack Mount i e connect OP Rack Mount 1 to 4...

Страница 21: ...d end equipment in the data closet This will connect to the data IN from the last OP Rack Mount on the SmartSwitch If a SmartSwitch is not used connect the data terminator to the data out of the last...

Страница 22: ...he speakers and channels have been specially laid out to accomplish the right sound in the environment you are installing the sound masking For example you will most likely notice that the speakers on...

Страница 23: ...aker for that channel Continue this sequence until all of the speakers in the channel run are completely wired There will be nothing connected to the last speaker on the OUT port and the end of each d...

Страница 24: ...19...

Страница 25: ...rminator Mic Pre Amp Optional Equipment Electrical Requirements One dedicated 120v 20 Amp circuit is suggested for the Lencore branded enclosure Installing Head End Equipment Din Rail and i LON This m...

Страница 26: ...unt to the connection marked AUDIO OUT on the MPI You must also connect a ground wire from the MPI to the first OP Rack Mount Doing this connects the MPI ground to the OP Rack Mount ground All wiring...

Страница 27: ...properly tied between OP Rack Mounts Have you made sure all Data and Audio and Speaker wires are tested and installed Check polarity of all wiring throughout 2 4 5 1 3 TIP TIP Check data wires by goi...

Страница 28: ...23...

Страница 29: ...24...

Страница 30: ...key or holding the key down Display 1 located on the left hand side of the OP displays the OP and DSP Neuron firmware versions Display 2 located on the right hand side of the OP displays OP operationa...

Страница 31: ...been selected use select the function you want to adjust Next select the channel by pressing or a zone by pressing Use the and to change the value for the channel The and can be pressed at any time as...

Страница 32: ...lume press or Source With the display in paging mode press until Source is displayed To change the source press or Note the Channel Mute and Unmute buttons are disabled for source selection Audio Musi...

Страница 33: ...and internal ambient Use and to scroll through the audio sources This will display the various voltage levels within the unit Press until Voltages is displayed Internal temperature Save automatically...

Страница 34: ...isplays Invalid Pairing Enter to Pair then pairing is necessary When the Rack Unit is powered for the first time the unit needs to be paired Display 1 will display the OP and Booting up Display 2 will...

Страница 35: ...ystem Configurator Training Software training for networked systems Closeout documentation creating proper as builts Troubleshooting and frequently asked questions A certified installer should walk aw...

Страница 36: ...on our YouTube Channel www youtube com user LencoreAcoustics Please feel free to use these reference sources for help with installation of Overview of each system and general applications OP Rack Mou...

Страница 37: ...for detailed information Testing should be performed monthly or more frequently if necessary 1 Test that all channels are generating masking as required 2 Test all channels designated for paging for p...

Страница 38: ...re frequently if necessary 1 Inspect and clean if necessary all air vent openings 2 Inspect and replace if necessary the AC power cord for exposed wires torn or worn insulation or a broken cord retain...

Страница 39: ...e product to comply with the requirements in the Standard for Control and Communication Units for Mass Notification Systems UL2572 certain programming features or options must be limited to specific v...

Страница 40: ...Revision Level Revision Date Description of Revision Revision Author A B 6 10 18 Initial Release M Cook 8 30 18 Added various notes for UL864 M Cook 35...

Страница 41: ...opyright protected No part of this manual can be copied used or distributed without prior authorization from Lencore Acoustics Corp Copyright 2016 REV5003 16 10 Lencore Acoustics Corp 1 Crossways Park...