LENCO 123SC Скачать руководство пользователя страница 2

If you have no lights, 

proceed 

(other pg)

 to 

“System Inoperative” 

GENERAL TROUBLESHOOTING

FOR 123SC TRIM TAB SYSTEM

FOR ADDITIONAL INFORMATION, CONTACT LENCO’S TECHNICAL SERVICE DEPARTMENT AT:
TEL: 772-288-2662     FAX:772-288-2566    EMAIL: [email protected]

11.08.08

This guide is intended to provide basic functional diagnostics and will assist in determining

the source of the problem. Choose Power Fault or Actuator Fault and follow the steps.

If you have this reading 

and are still experiencing 

a problem, call Lenco. 

If you have any of these readings, 

proceed to

“Actuator Inoperative”

NO LIGHTS

Are any lights on the Digital Switch illuminated? 

POWER FAULT

STBD SIDE FAULT

PORT SIDE FAULT

BOTH SIDE FAULT

GOOD READING

LIGHTS

LIGHTS

OPERATIONAL TEST

 

 

   

further technical assistance.

Step A:

 

Step B:

 

Press the left-side button on the switch labeled “DOWN”. The starboard actuator 

should extend and the left-side indicator lights should track.

Press the right-side button on the switch labeled “UP”. The port actuator should 

extend and the right-side indicator lights should track.

 • If fault reading is present at the 

opposite side

 of the key pad, the actuator (or its 

connections) may be defective.  

Proceed to Step 4.

• If fault reading is present at the 

same side

 of the key pad, the control box may be 

defective.  Call Lenco Marine for 

Press & Hold

PG 2

Lights 
should 
track

STARBOARD

PORT

Perform the OPERATIONAL TEST.

                 

                 

ACTUATOR INOPERATIVE (Actuator Fault)

Step 1:

 

Step 2:

 If the fault continues, s

Check to make sure that the Deutsch Connectors are 

            firmly attached.  If the connection is loose, firmly press 
            the two connectors together.

wap the connections to the 

            actuators. Disconnect actuators from control box and 
            reconnect actuators to opposite control box outputs. 

Step 3: 

White/Red Wire
& Black/Red Wire
Port Deutsch Connec.

White/Green Wire 
& Black/Green Wire
Starboard Deutsch Connec.

1

Swap Connections

2

Remove the wire leads
from the connector by 
depressing the small 
latch inside the 
connector housing.

Extend the Actuator:
White Terminal to Positive 
(+)  Battery Terminal.
Black Terminal to Negative 
(-)  Battery Terminal.

Remove the orange wedge
by lifting the wedge from the
connector with a small flat 
head screwdriver or Deutsch 
connector tool.

6

5

4

Step 4: 

If fault continues, disconnect the Deutsch Connectors and remove the 

            orange wedge.  

Step 5: 

Remove the wire leads from the connector by depressing the small 

            latches inside the connector housing and pulling on the wire leads.

Step 6:

 Once the wires are removed from the housing, touch the white wire 

            leads to a Positive (+) 12V Battery Terminal and the black wire leads 
            to a Negative (-) 12V Battery Terminal.  The actuator should extend 
            while connected to the battery.  Reverse the polarity of the wire leads 
            to the battery terminals and the actuator should retract.
                If the actuator does not extend and retract, replace the actuator.
                If the actuator extends and retracts properly, re-assemble the 
                  connector taking care to properly seat the wire leads into the 
                  connector housing.  

Proceed to Step 7.

 

Step 7:

 Attach the port and starboard connectors to the system. If the fault reading continues, 

            contact Lenco’s Customer Service at: 

 or 772-288-2662

• 
• 

[email protected]

Press & Hold

Lights 
should 
track

Отзывы: