LENCO 123SC Скачать руководство пользователя страница 1

If you have no lights, 

proceed to 

“System Inoperative” 

Operate the system in TEST MODE. 

                

                 • If the system works in the Test Mode there is a problem with the accessory signal.
                      Check for proper connection to the orange accessory wire of the control box.
                      

 

                 • If the system does not work in Test Mode continue to 

Step 2.

Verify there is 12V or 24V at the Power Plug: Disconnect the Power Plug from the control box’s power  

            

and measure voltage using a DC voltmeter.

                 • If 12V or 24V is 

not

 at the Power Plug across the two pins,

                       step 1: Check the fuse or circuit breaker (between 
                                  battery and control box)
                       step 2: 

 

                       step 3: 

                       step 4: Check battery switch.
                
                 • If 12V or 24V 

is

 at the Power Plug across the two pins,

                       Check the key pad connection.

Call Lenco Marine for further technical assistance.

SYSTEM INOPERATIVE (Power Fault)

NOTE:Under normal operation the control box’s orange accessory wire requires a 12V level

                                or a tachometer signal to turn the control box ON (top triangular LEDs on switch are lit)

Step 1:

 

Step 2:

 

Verify that the power connection is firmly

                                  attached and that 12 or 24 volts is available.

Verify the Orange wire is connected to a 12 

                                  or 24V source or an Engine Tach Signal.

Step 3:

 

receptacle 

GENERAL TROUBLESHOOTING

FOR 123SC TRIM TAB SYSTEM

FOR ADDITIONAL INFORMATION, CONTACT LENCO’S TECHNICAL SERVICE DEPARTMENT AT:
TEL: 772-288-2662     FAX:772-288-2566    EMAIL: [email protected]

11.08.08

Lenco actuators come with 6FT actuator cables that feature Deutsch terminations.

Boat builders may use a separate wire harness connecting power and actuators to control box.

If you’re not certain if there is a separate connection in your boat, contact the boat manufacturer.

This guide is intended to provide basic functional diagnostics and will assist in determining

the source of the problem. Choose Power Fault or Actuator Fault and follow the steps.

If you have this reading 

and are still experiencing 

a problem, call Lenco. 

If you have any of these readings, 

proceed 

(on the next page)

to

 

“Actuator Inoperative”

NO LIGHTS

Are any lights on the Digital Switch illuminated? 

POWER FAULT

STBD SIDE FAULT

PORT SIDE FAULT

BOTH SIDE FAULT

GOOD READING

LIGHTS

LIGHTS

TEST MODE

Press and hold all four keypad buttons down for approximately 

three seconds. The LEDs on the keypad should track down than back up 
and stop with the top triangular LED lit on each side.

Press the left side button on the keypad labeled “DOWN”. The 

starboard actuator should extend and the left side indicating lights should 
track.

Press the right side button on the keypad labeled “UP”. The port 

actuator should extend and the right side indicating lights should track.

Momentarily press all four keypad buttons down simultaneously.

Both actuators should retract fully and keypad should have no indicating 
lights on.

Step 1:

 

Step 2:

 

Step 3:

 

Step 4: 

Press &
Hold 3 Sec.

Triangular 
LEDs Should
Be Illuminated

Key Pad

Connection

20 Amp Fuse

1

Orange Wire Connection

2

Power Wire Connection

3

4

Battery switch 
(images would vary)

PG 1