If you have no lights,
proceed to
“System Inoperative”
Operate the system in TEST MODE.
• If the system works in the Test Mode there is a problem with the accessory signal.
Check for proper connection to the orange accessory wire of the control box.
• If the system does not work in Test Mode continue to
Step 2.
Verify there is 12V or 24V at the Power Plug: Disconnect the Power Plug from the control box’s power
and measure voltage using a DC voltmeter.
• If 12V or 24V is
not
at the Power Plug across the two pins,
step 1: Check the fuse or circuit breaker (between
battery and control box)
step 2:
step 3:
step 4: Check battery switch.
• If 12V or 24V
is
at the Power Plug across the two pins,
Check the key pad connection.
Call Lenco Marine for further technical assistance.
SYSTEM INOPERATIVE (Power Fault)
NOTE:Under normal operation the control box’s orange accessory wire requires a 12V level
or a tachometer signal to turn the control box ON (top triangular LEDs on switch are lit)
Step 1:
Step 2:
Verify that the power connection is firmly
attached and that 12 or 24 volts is available.
Verify the Orange wire is connected to a 12
or 24V source or an Engine Tach Signal.
Step 3:
receptacle
GENERAL TROUBLESHOOTING
FOR 123SC TRIM TAB SYSTEM
FOR ADDITIONAL INFORMATION, CONTACT LENCO’S TECHNICAL SERVICE DEPARTMENT AT:
TEL: 772-288-2662 FAX:772-288-2566 EMAIL: [email protected]
11.08.08
Lenco actuators come with 6FT actuator cables that feature Deutsch terminations.
Boat builders may use a separate wire harness connecting power and actuators to control box.
If you’re not certain if there is a separate connection in your boat, contact the boat manufacturer.
This guide is intended to provide basic functional diagnostics and will assist in determining
the source of the problem. Choose Power Fault or Actuator Fault and follow the steps.
If you have this reading
and are still experiencing
a problem, call Lenco.
If you have any of these readings,
proceed
(on the next page)
to
“Actuator Inoperative”
NO LIGHTS
Are any lights on the Digital Switch illuminated?
POWER FAULT
STBD SIDE FAULT
PORT SIDE FAULT
BOTH SIDE FAULT
GOOD READING
LIGHTS
LIGHTS
TEST MODE
Press and hold all four keypad buttons down for approximately
three seconds. The LEDs on the keypad should track down than back up
and stop with the top triangular LED lit on each side.
Press the left side button on the keypad labeled “DOWN”. The
starboard actuator should extend and the left side indicating lights should
track.
Press the right side button on the keypad labeled “UP”. The port
actuator should extend and the right side indicating lights should track.
Momentarily press all four keypad buttons down simultaneously.
Both actuators should retract fully and keypad should have no indicating
lights on.
Step 1:
Step 2:
Step 3:
Step 4:
Press &
Hold 3 Sec.
Triangular
LEDs Should
Be Illuminated
Key Pad
Connection
20 Amp Fuse
1
Orange Wire Connection
2
Power Wire Connection
3
4
Battery switch
(images would vary)