LEM POWERFACTOR 3 Скачать руководство пользователя страница 7

5

Rules for installation and use

ATTENTION !!!

The POWERFACTOR series amplifiers generate high voltage on output.
To avoid the risk of electric shocks, DO NOT TOUCH any bare wires when the unit is
switched on.
This manual contains important information for correct safe use: read it carefully
before using your amplifier.

✔ 

✔ 

✔ 

✔ 

✔ 

Connection to the mains supply

Before connecting the amplifier to the mains socket, always make certain that:
- the electric system and mains socket have an adequate grounding, compatible with the safety norms
(if you’re uncertain, consult specialized personnel);
- the mains voltage corresponds to that shown on the rear of the unit (an allowance of up to ±10% is
accepted);
- the power cord is not damaged and has no bare wires;
- the on/off switch is in the OFF position.
Make sure the amplifier is also off before disconnecting the power cord from the mains socket.

✔ 

✔ 

✔ 

✔ 

✔ 

Switching on and off

In your sound reinforcement system, always switch on the amplifier after all the other equipment and
always switch it off before anything else, if possible with the Gain controls set at minimum: this will avoid
annoying and sometimes dangerous signal peaks.
(NB: when switched on, the amplifier is “muted” for approximately 4 seconds.
It’s normal that when the unit is switched on the various LEDs on the front panel light up for a few
moments).

✔ 

✔ 

✔ 

✔ 

✔ 

Installation and use

Your POWERFACTOR amplifier generates decidedly high power, so install it in locations which ensure
correct air circulation. Avoid long exposure to direct sunlight, sources of strong heat, powerful vibrations,
very dusty or particularly damp surroundings or (even worse) rain: this will avoid possible faulty operation,
deterioration or even electric shocks and fires.
The air for cooling the unit is forced in through the vents in the front panel and out through those on the
rear panel, so make certain that there’s sufficient space round the amplifier to allow adequate air
circulation.
If racks or flight-cases are used, make sure that airflow is unobstructed: don’t install the amplifiers in
racks or flight-cases with closed backs.
Since part of the heat is dissipated via the metal bottom of the amplifier, it’s advisable to install the
amplifiers with at least one rack unit space between them.

✔ 

✔ 

✔ 

✔ 

✔ 

Audio connections

Remember to always connect and disconnect other units with the amplifier switched off.
Always use good quality cables of the appropriate type, opportunely described in the “Connection Cables”
chapter of this manual.
Take care of your connector cables, a very frequent cause of small/big problems. Check their condition fre-
quently. Always grip them by the connector, avoid pulling them forcefully and wind them without forming knots
or sharp bends: they’ll last longer this way and be more reliable, which is a definite advantage.

 Rules for installation and use 

Содержание POWERFACTOR 3

Страница 1: ......

Страница 2: ...ctrician to replace your obsolete outlet Do not defeat the safety purpose of the plug 9 The power supply cord of the product should be unplugged from the outlet when left unused for a long period of time When unplugging the power supply cord do not pull on the cord but grasp it by the plug 10 Care should be taken so that object do not fall and liquid are not spilled into the enclosure through open...

Страница 3: ...nstallation and use 5 Functions Controls 7 POWER ON OFF 7 INPUT ATTENUATORS 7 METERs 7 PROTECT LEDs 8 HI FREQ LEDs 8 SIGNAL LEDs 8 TEMP LED 8 READY LED 8 Connection panel 9 INPUTS 9 LINK 9 OUTPUTS 9 A C 9 Connection examples 10 Stereo 10 Stereo Link 11 Parallel 12 Connection cables 13 Power cords 13 Signal cables 14 Technical specifications 15 Diagrams 16 POWERFACTOR 3 response curves 16 POWERFACT...

Страница 4: ...ipation ü Radical reduction of dimensions and weight ü Remarkable increase in power ü Unbeatable constant efficiency values ü Accurate tone definition ü Great long term sturdiness and reliability Active Power Factor Correction The active power factor correction is an exclusive function which contributes to distinguishing POWERFACTOR amplifiers from other switching systems Simulating a purely resis...

Страница 5: ...e same weight and dimensions just 9 5 kg in 1 rack unit A result that speaks for itself and can be effectively summed up as really small really light and really powerful amplifiers Total control As well as the structural technology a series of patented devices ensures cutting edge figures for all parameters slew rate damping factor distortion frequency response etc POWERFACTOR amplifiers are thus ...

Страница 6: ...ce trips in the event of short circuiting or overloading at output transistor level It s absolutely unnoticeable when not enabled When this protection trips the PROTECT LED lights up Loudspeaker protection In the event of output transistor breakdown or other forms of faulty operation sending DC voltage or excessive subsonic frequencies to one or both outputs a protection device immediately cuts of...

Страница 7: ... up for a few moments Installation and use Your POWERFACTOR amplifier generates decidedly high power so install it in locations which ensure correct air circulation Avoid long exposure to direct sunlight sources of strong heat powerful vibrations very dusty or particularly damp surroundings or even worse rain this will avoid possible faulty operation deterioration or even electric shocks and fires...

Страница 8: ...es lastly and one by one Protection and maintenance The amplifier is built in shock resistant material Nevertheless protect it during transport with a flight case to avoid the risk of any casual accidents After long periods of use particularly in dusty surroundings accumulated dust may interfere with the unit s cooling Without opening the amplifier and making certain it s disconnected from the mai...

Страница 9: ... completely attenuated and therefore not sent to the channel of the amplifier and 0 fully open i e nominal level the signal is not attenuated in any way so is fed to the amplifier channel at the same level at which it arrives on input NB between 30dB and 0dB the attenuators intervene with a logarithmic scale METERs Output level LED indicators Allow to monitor the level of the respective channels o...

Страница 10: ...IGNAL LEDs Indicators of signals on input If lit indicate that the relative inputs of the amplifier channels are receiving an audio signal TEMP LED Thermal protection indicator The LED s status indicates 3 possible conditions LED off protection disabled normal running conditions LED flashing protection enabled 60 C reached the thermal control device gradually reduces output gain LED lit steadily p...

Страница 11: ...nnector b the signal can be forwarded to the input of another amplifier using the free connector OUTPUTS Neutrik SPEAKON connectors minimum impedance 2 Ω Ω Ω Ω Ω The outputs to be connected to the loudspeaker enclosures To avoid possible damage to the loudspeaker enclosures only connect enclosures or speaker systems compatible with the power load and impedance limits indicated for the amplifier re...

Страница 12: ...10 Connection examples Connection examples ...

Страница 13: ...11 Connection examples ...

Страница 14: ...12 Connection examples ...

Страница 15: ...cables SPEAKON power connector The 4 way SPEAKON connector of the POWERFACTOR s power outputs has the PIN 1 2 and 1 2 linked together This allows the power to be carried along 4 wires instead of 2 thus reducing the dissipation of energy especially in case of very long distances 3 different cables can be used with this kind of connection as shown below 2 wire cable it s a standard cable which can b...

Страница 16: ...14 Connection cables Unbalanced XLR F connector Unbalanced XLR M connector Balanced XLR F connector Balanced XLR M connector Signal cables ...

Страница 17: ...NERAL SPECIFICATIONS POWERFACTOR 3 POWERFACTOR 5 PROTECTIONS AMPLIFIER LOUDSPEAKERS CONTROLS INDICATORS CONNECTORS INPUT OUTPUT POWER SUPPLY DIMENSIONS WEIGHT 9 5 kg 9 5 kg 483x44x450 mm WxHxD 0 02 from 0 1W to full power typical 0 01 ON OFF switch Input level control for each channel SIGNAL LEVEL 2 x 10 LED bar PROTECT 2 red LEDs HI FREQ 2 yellow LEDs SIGNAL 2 green LEDs ON READY 1 green LED TEMP...

Страница 18: ... 0 01 10 0 02 0 05 0 1 0 2 0 5 1 2 5 2 1k 5 10 20 50 100 200 500 W POWERFACTOR 3 Intermodulation SMPTE Vs Power 0 01 10 0 02 0 05 0 1 0 2 0 5 1 2 5 2 1k 5 10 20 50 100 200 500 W POWERFACTOR 3 Intermodulation DIM 100 Vs Power Diagrams ...

Страница 19: ... 2 5 2 1k 5 10 20 50 100 200 500 W POWERFACTOR 3 THD Vs Power 4 Ohm 0 01 10 0 02 0 05 0 1 0 2 0 5 1 2 5 20 10k 20k 50 100 200 500 1k 2k 5k Hz POWERFACTOR 3 THD Vs Freq 8 Ohm 1 3 rated output power POWERFACTOR 3 response curves Diagrams ...

Страница 20: ...esponse curves 0 01 10 0 02 0 05 0 1 0 2 0 5 1 2 5 2 1k 5 10 20 50 100 200 500 W POWERFACTOR 5 Intermodulation SMPTE Vs Power POWERFACTOR 5 Intermodulation DIM 100 Vs Power W 10 0 05 0 1 0 2 0 5 1 2 5 0 01 0 02 Diagrams ...

Страница 21: ...01 10 0 02 0 05 0 1 0 2 0 5 1 2 5 2 1k 5 10 20 50 100 200 500 W POWERFACTOR 5 THD Vs Power 4 Ohm 2k 0 01 10 0 02 0 05 0 1 0 2 0 5 1 2 5 20 10k 20k 50 100 200 500 1k 2k 5k Hz POWERFACTOR 5 THD Vs Freq 8 Ohm 1 3 rated output power Diagrams ...

Страница 22: ...20 Block diagram Diagrams ...

Страница 23: ...om GENERALMUSIC S p A GENERALMUSIC reserves the right to make any aesthetic functional or design modification to any of its products without any prior notice GENERALMUSIC assumes no responsibility for the use or application of the products or circuits described herein PRINTED IN ITALY FEDERAL COMMUNICATIONS COMMISSION NOTE This equipment has been tested and found to comply with the limits for a Cl...

Страница 24: ...Sales Division 47842 S Giovanni in Marignano RN Via delle Rose 12 tel 39 0541 959511 fax 39 0541 957404 Internet http www lemaudio com ...

Отзывы: