Procedure
-
start from visualisation mode (display fixed switched on) of the first cluster’s level settlement.
-
press the “UP” key: the display will show the F1 cluster .
-
The display will also indicate the F1 cluster’s start channel by the lighting of the second LED.
-
press “UP” again .
-
the display will show the F1 cluster’s stop channel followed by a dot
F I 27.
Note:
If the start channel is at the same value as the stop one ( single-channel setting) the display will indicate
this mode viewing the word
o F
as cluster’s stop channel
F I oF.
To reset the cluster’s start channel:
-
select the desired cluster on the display.
-
the lighting of the second LED confirms that you are at the cluster’s start channel.
-
press the “ENTER” key .The display will start blinking.
-
press “UP” to increase the channel’s number or “DOWN” to decrease it.
-
press “ENTER” again to confirm your choice.
To reset the cluster’s stop channel:
-
press the “UP” key.
-
the lighting of the fourth LED confirms that you are at the cluster’s stop channel.
-
press the “ENTER” key .The display will start blinking.
-
press “UP” to increase the channel’s number or “DOWN” to decrease it.
-
press “ENTER” again to confirm your choice.
To deactivate the cluster’s start or stop channel:
-
press the “UP” and “DOWN” keys simultaneously.
-
the display will show the word
o F.
Note:
Channel overlapping is possible and it is shown on the display by the rapid blinking of the overlapped
clusters.
Note:
The setting of the F1 cluster’s start channel at the value 21 and of the stop channel at the value 24 while
the F2 cluster has the start channel at the value 24 and the stop channel at the value 26 implicates an
overlapping of the F1 cluster’s stop channel with the F2 cluster’s start channel.