General Safety

When developing the Lely Calm View the latest standards were implemented to make this product as safe
as possible. However, there are a few additional rules that should be observed.

Do not use the products in any way that might violate the integrity of others.

Always follow the laws and legislations that apply in your country.

Do not leave plastic packaging material near children or animals to avoid the risk of suffocation.

Do not open the camera enclosure as it is a non-serviceable product.

Lely resigns all responsibility that might occur from abuse or incorrect use of the products. Always
follow the instructions in this manual.

Read and understand this manual and all safety signs before you install parts of the Lely Calm View.

Only trained persons are permitted to operate the Lely Calm View.

Always have the telephone number of the nearest medical centre close at hand.

Contact your nearest Lely service provider if you have any questions.

3.3

Statement for Class A digital device acc. to FCC 15.105

This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to
correct the interference at his own expense.

3.4

Electrical Safety

The Lely Calm View shall only be used in combination with an external approved (for example EN
61558-2-16 or EN 62368-1) power supply which has the required insulation barrier.

Only an authorized electrician must install the electrical power supply for the system components.

Only an authorized electrician may work on the electrical installation.

Make sure the electrical grounding of the electrical system and all parts of the machine meet the local
rules and regulations.

Keep all cables properly protected and out off reach of animals.

Prevent damage by vermin.

Replace any damaged electrical lines, conduits, switches and components immediately.

in n o vato rs in  ag ric u ltu re

Содержание 5.1701.0101.0

Страница 1: ...www lely com LelyIndustriesN V Installation Operator manual EN English Original 5 1701 8500 0 Lely Calm View...

Страница 2: ...INTENTIONALLY BLANK 5 1701 8500 0 innovators in agriculture...

Страница 3: ...icrofilm or any other process whatsoever without prior permission in writing by Lely Holding B V Although the contents of this publication have been compiled with the greatest possible care Lely canno...

Страница 4: ...INTENTIONALLY BLANK 5 1701 8500 0 4 Trademarks Copyright and Disclaimer innovators in agriculture...

Страница 5: ...5 1701 8500 0 List of Included Amendments 5 List of Included Amendments Issue Date yy mm Revision Chapter s Remarks 2021 07 New release innovators in agriculture...

Страница 6: ...INTENTIONALLY BLANK 5 1701 8500 0 6 List of Included Amendments innovators in agriculture...

Страница 7: ...The recommendations are meant to serve as guidelines All instructions pictures and specifications in this manual are based on the latest information that was available at the time of publication Your...

Страница 8: ...2 Type and serial number plate 3 Cover lid Always include the type and serial number of your Lely Calm View when you contact your local Lely service provider or order spare parts Figure 1 Type and Ser...

Страница 9: ...f serious injuries and considerable damage to material Only technicians certified by Lely Industries are authorized to do maintenance on the machine except for the maintenance done by the operator as...

Страница 10: ...Service Provider We suggest you write the telephone number and email address of your local service provider contact in the table below This makes sure you can easily find the information Telephone nu...

Страница 11: ...rage Operational Environmental Specifications 4 1 4 2 Power Specifications 4 1 4 3 Camera Specifications 4 1 5 Description and Operation 5 1 5 1 Component description 5 1 5 2 Operation 5 2 6 Installat...

Страница 12: ...INTENTIONALLY BLANK 5 1701 8500 0 12 Table of Contents innovators in agriculture...

Страница 13: ...line vision and image creation processing management viewing and data analysis The information in this manual is for the installation and operators The operator uses the information to program and ope...

Страница 14: ...INTENTIONALLY BLANK 5 1701 8500 0 1 2 Introduction innovators in agriculture...

Страница 15: ...ed as an aid to the farming industry in the display detection counting and classification of young stocks young calves and heifers The system is intended to operate in barn conditions at a height betw...

Страница 16: ...INTENTIONALLY BLANK 5 1701 8500 0 2 2 Intended Use innovators in agriculture...

Страница 17: ...if not avoided will result in death or serious injury Warning Indicates a hazardous situation which if not avoided could result in death or serious injury Caution Indicates a hazardous situation which...

Страница 18: ...y with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operat...

Страница 19: ...Always block the cow traffic when you install the Lely Calm View or do maintenance on the Lely Calm View Always follow local rules and regulations Always use PPE Personal Protective Equipment accordin...

Страница 20: ...INTENTIONALLY BLANK 5 1701 8500 0 3 4 Safety innovators in agriculture...

Страница 21: ...r supply 19 2 28 8 VDC 96 Wmax PoE 802 3bt type 3 42 5 57 0 VDC 51 Wmax Source current CAN Aux Power 19 2 28 8 VDC 28 8 Wmax Source current CAN PoE Power 19 2 28 8 VDC 14 4 Wmax Source current Aux Pow...

Страница 22: ...INTENTIONALLY BLANK 5 1701 8500 0 4 2 Specifications innovators in agriculture...

Страница 23: ...escription and Operation 5 1 Component description The Camera has the following components Camera house Cover lid 24V external power Power over Ethernet Breather CAN device Digital Input Output device...

Страница 24: ...thernet The camera s power can be supplied by an auxiliary 24V source or via Power over Ethernet The two power sources are mutually exclusive with the auxiliary 24V supply having the higher priority T...

Страница 25: ...ks for the farm and the purchase of equipment necessary to use the Lely Calm View A decent internet speed is required to run the applications on the Lely View Additional power supply optional CAN tag...

Страница 26: ...scription Camera Marking Phoenix connector Phoenix Counterpart Connection diagram 24 supply PWR 1457539 1543058 Pin 1 24V supply Pin 2 4 5 nc Pin 3 GND supply Ethernet 1Gbps ETH 1402457 1417443 Pin 1...

Страница 27: ...art Connection diagram CAN interface CAN 1457652 1543003 Pin 1 GND Pin 2 24V CAN Pin 3 GND Pin 4 CAN_H Pin 5 CAN_L IO interface 2x DIO 1457652 1543003 Pin 1 24V_ DIO Pin 2 DIO_2 Pin 3 GND Pin 4 DIO_1...

Страница 28: ...ector distance for free range 1 68 m 5 51 ft 2 Height of lens bottom of the camera y direction When measuring calves 0 4mnths Camera lens calf 1800 mm 70 8 in When measuring heifers 10 24 mnths Depend...

Страница 29: ...ffic before the start of the installation Always use a proper scaffold or a double sided ladder when you install the Lely Calm View or do maintenance on the Lely Calm View Follow local regulations Ins...

Страница 30: ...rated at 24V 10 and has a minimum output current of 4A Check that the Gigabit PoE switch is minimum PoE 802 3bt type3 capable or better Check that the GPIO device has a maximum load of 0 7A at 24V The...

Страница 31: ...orque tool 1 Determine right position of mounting pole see Determine placement of the camera on page 6 3 2 Mark the four holes 3 Drill the holes and insert the plugs 4 Install the pole with the four b...

Страница 32: ...ith the clamp 1 clamp plate 4 to the horozontal bar plate 5 with the nuts 2 7 and washers 3 6 see figure 6 on page 6 8 Use a double sided ladder when installing the horizontal bar for heifers Figure 6...

Страница 33: ...the correct distance by sliding the inner tube 2 in to the outer tube 1 and lock the tubes with the two adjustment bolts 4 and nuts 3 see figure 7 on page 6 9 Figure 7 Adjust the horizontal bar KEY 1...

Страница 34: ...s 5 and nuts 4 see figure 8 on page 6 10 Figure 8 Install the adapter plate to the camera KEY 1 Bracket 2 Bolt 3 Adapter plate 4 Nut 5 Washer 6 Bolt 8 Install the adapter 3 with the camera to the brac...

Страница 35: ...g caps on the connectors which are not in use 10 Check the functionality of the Lely Calm View and peripherals before installation 11 Unplug the power of the Lely Calm View on the not device side When...

Страница 36: ...lt 2 Horizontal bar 15 Guide the cables via the horizontal bar to a safe position 6 4 Set the Settings in the App 1 Measure the height from the camera lens to the Solid concrete slatted floor 2 Launch...

Страница 37: ...rous and must be done only by qualified recycling organizations All components must be disposed in compliance with the local rules and regulations Lubricants and fluids must be disposed correctly to p...

Страница 38: ...INTENTIONALLY BLANK 5 1701 8500 0 7 2 Disposal innovators in agriculture...

Страница 39: ...2012 19 EC we would like to notify you that this product might contain regulated materials which upon disposal according to the WEEE directive require special reuse and recycling processing For this...

Страница 40: ...INTENTIONALLY BLANK 5 1701 8500 0 8 2 WEEE innovators in agriculture...

Страница 41: ...5 1701 8500 0 EC Declaration of Conformity 9 1 9 EC Declaration of Conformity 9 1 innovators in agriculture...

Страница 42: ...INTENTIONALLY BLANK 5 1701 8500 0 9 2 EC Declaration of Conformity innovators in agriculture...

Страница 43: ......

Страница 44: ...www lely com CornelisFvanFderFLelylaanF1 NL 3147FPB FMaassluis Tel 31F 0 88F F12F28F221 Fax 31F 0 88F F12F28F222 Lely Industries N V...

Отзывы: