detergent powder (F or PLA9201) into the filter. Insert the filterholder (G) in the
group head (13) and lift the lever (14) for 10 seconds. Stop the function by
lowering the lever completely and wait for 10 seconds. Repeat the procedure 10
times (Pic 15.2).
Remove the filterholder (G) from the group and rinse it with hot water from the
brewing group (Pic 15.3).
Re-insert the filterholder (G) in the group head and repeat the previous operation
5 times for 10 seconds each time, without detergent powder.
Remove the filterholder (G) and take out the blind filter (C). Empty the drainage tray
(17) and rinse the filterholder (G), the filters and the tray (17) with plenty of tap water.
15.4
10x5”
Steam wand cleaning. Fill a jug with 500 ml of cold
water, add the content of 1 bottle of detergent liquid
(F or PLA9203) and immerse the steam wand (7) in
this solution.
Open the knob (3) and dispense steam for 5
seconds. Stop the function and wait for 5 seconds.
Repeat the operation 10 times (Pic 15.4).
Repeat the entire procedure using 1 l of fresh water
to rinse the steam wand (7) properly.
16. Annual cleaning
The descaling of the hydraulic circuit of the machine must be done every year to
ensure longevity and constant performances. This operation must be done by a
specialized technician. You can see the centres authorized to run this procedure
on our website: LELIT.COM