29
9.7.2 Dialling in sequence
Behaviour on dialling-in mode can be read out or modified as follows:
OFF
ON
PROG
*
.
9
.
7
.
1
.
3
7 0
#
.
#
.
*
.
Value
#
.
OFF
ON
PROG
Value
Comment
0
answers call directly after the programmed ringing cycles
1
answers call after a two-step dialling -in sequence (2 ringing, hand up, wait 20 sec,
dialling in again
(=factory setting)
9.7.3 Connection mode after dialling-in
Phone connection mode after dialling-in can be read out or modified as follows:
OFF
ON
PROG
*
.
9
.
7
.
1
.
3
7 1
#
.
#
.
*
.
Value
#
.
OFF
ON
PROG
Value
Comment
0
does not signal a dialling in and switches to listening-in connection (=factory setting)
1
establishes hands-free connection announced by five gong signals.
9.7.4 Handling of incoming calls
Answering incoming call by pressing the emergency button or any key can be selected as follows:
OFF
ON
PROG
*
.
9
.
7
.
1
.
3
7 2
#
.
#
.
*
.
Value
#
.
OFF
ON
PROG
Value
Comment
0
is not responding by activation of the emergency button or any key of the alarm unit
1
Call can be answered by pressing the emergency button or any key of alarm unit
(=factory setting)
9.8 Remote programming
The calling numbers as well as the sequence of the calling numbers are programmable during
phone
connection
. This function is disabled (factory setting), but can be enabled as follows:
9.8.1 Enabling of remote programming
Remote programming can be read out or modified as follows:
OFF
ON
PROG
*
.
9
.
7
.
1
.
3
7 6
#
.
#
.
*
.
Value
#
.
OFF
ON
PROG
Value
Comment
0
cannot be remote programmed
(=factory setting)
1
is ready for remote programming.
9.8.2 Remote programming of calling number and calling number sequence
If remote programming is enabled calling numbers/sequence can be re-programmed during
phone connection:
1. Enter DTMF * *
n
(
n
=> see chart below)
Current calling number/ calling number sequence will be announced. If you want to change, continue at
point two. Otherwise enter DTMF # .
2. Enter DTMF *
3. Enter new number/sequence
After entering of the last digits, wait ten seconds. New number/ sequence will be announced, followed
by the request to enter DTMF
n
to confirm change. If you do not confirm within 10 seconds or if
another key is pressed the message „programming: abort“ will be announced. In this case the old value
remains active.
<
n>
Comment
Programming according to
0
Calling number sequence (max. 9 digits)
Section 5.2.2
1
Calling number 1 (max. 24 digits)
..
Calling number .. (max. 24 digits)
9
Calling number 9 (max. 24 digits)
Section 5.1
#
SPECIAL - CASE: Phone connection is terminated and a test call is initialised with the current calling
number sequence and calling numbers => announcement: “Alarm due to programming“
Value
Value
Value
Value
Содержание EA-8-WRL868