Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 3: Operation
Read-Only Parameters
Many of the read-only parameters are also represented by LEDs on the
front of the module’s card edge. See
for the location of these
LEDs.
Figure 3-2.
Location of LEDs
Operating Notes
When setting the control parameters on the AES6800
+
, observe the
following:
•
When you change a parameter, the effect is immediate. However,
the module requires up to 20 seconds to save the latest change.
After 20 seconds, the new settings are saved and will be restored if
the module loses power and must be restarted.
When setting the control parameters on the , observe the
following:
•
When the module is set to remote control, the reclocking mode is
controlled by the CCS control software application. When the
module powers up with remote selected, the reclocking mode is set
to the last known value.
•
When the module is set to local control, the reclocking mode is
controlled by adjusting the card-edge jumper to the appropriate
setting. Reclocking mode selections are reflected in the CCS
control software application. Any remote attempts to adjust the
reclocking mode will have no effect.
•
If a card-edge jumper is not installed the reclocking mode is set to
Auto.